Power Seat Module Right (PSR)
Connector A
SIGNAL TABLE, CONNECTOR A
| Breakout box connection | Control module terminal | Signal type | Ignition on Inactive/active |
Ignition off Inactive/active |
Miscellaneous |
| - | #A1 | Ground | U low | U low | - |
| - | #A2 | Motor -, common | U = U low /U = U bat | U = U low /U = U bat | M1-, M2-, M3-, M4- |
| - | #A3 | Motor 4+ | U = U low /U = U bat | U = U low /U = U bat | Regulates front edge angle of seat cushion |
| - | #A4 | Motor 3+ | U = U low /U = U bat | U = U low /U = U bat | Regulates seat cushion height |
| - | #A5 | Motor 2+ | U = U low /U = U bat | U = U low /U = U bat | Regulates backrest angle |
| - | #A6 | Motor 1+ | U = Ulow /U = Ubat | U = Ulow /U = Ubat | Regulates front/rear adjustment of seat |
| - | #A7 | Power supply | U = U bat | U = U bat | - |
Connector B
SIGNAL TABLE, CONNECTOR B
| Breakout box connection | Control module terminal | Signal type | Ignition on Inactive/active |
Ignition off Inactive/active |
Miscellaneous |
| #43 | #B1 | Switch, forward | U = U low /U = U bat | U = U low /U = U bat | Regulates front/rear adjustment of seat cushion and backrest angle for easy entry |
| #44 | #B2 | Ground | U low | U low | - |
| #45 | #B3 | Communication cable, control module (CAN-L) | 1.5-2.5 V | 1.5-2.5 V | - |
| #46 | #B4 | Communication cable, control module (CAN-H) | 2.5-3.5 V | 2.5-3.5 V | - |
| #47 | #B5 | Switch, rearward | U = U low /U= U bat | U = U low /U= U bat | Regulates front/rear adjustment of seat cushion and backrest angle for easy entry |
| #48 | #B6 | Signal supply, extended X | U = U bat | U = U bat | - |
| #49 | #B7 | Hall sensor 4 | U = U bat
/a pulsed signal with duty= 50% f<= 100 Hz |
U = U bat
/a pulsed signal with duty= 50% f<= 100 Hz |
One pulse/motor rotation Pulse high value: U bat Pulse low value: 7.0-9.0 V (60-70% of U bat ) |
| #50 | #B8 | Hall sensor 3 | U = U bat
/a pulsed signal with duty= 50% f<= 100 Hz |
U = U bat
/a pulsed signal with duty= 50% f<= 100 Hz |
One pulse/motor rotation Pulse high value: U bat Pulse low value: 7.0-9.0 V (60-70% of U bat ) |
| #51 | #B9 | Hall sensor 2 | U = U bat
/a pulsed signal with duty= 50% f<= 100 Hz |
U = U bat
/a pulsed signal with duty= 50% f<= 100 Hz |
One pulse/motor rotation Pulse high value: U bat Pulse low value: 7.0-9.0 V (60-70% of U bat ) |
| #52 | #B10 | Hall sensor 1 | U = U bat
/a pulsed signal with duty= 50% f<= 100 Hz |
U = U bat
/a pulsed signal with duty= 50% f<= 100 Hz |
One pulse/motor rotation Pulse high value: Ubat Pulse low value: 7.0-9.0 V (60-70% of Ubat ) |
| #53 | #B11 | Hall sensor 5 | U = 5 V | U = 5 V | Supply hall sensor backrest |
| #54 | #B12 | Ground/signal Hall sensor 5 |
U = 0.9-3.7 V | U = 0.9-3.7 V | Ground/Control signal hall sensor backrest |
| #55 | #B13 | - | - | - | - |
| #56 | #B14 | Ground, Hall sensor 1-4 | U = U low | U = U low | Common ground |