Home >> Volvo >> 2009 >> C30 R-Design, Automatic >> Repair and Diagnosis (Single Page) >> Heating, Ventilation & A/C (HVAC) >> HVAC Control Systems >> Climate Control Module (CCM) - Description Of Frozen Values >> HVAC >> Description Of Frozen Values, Climate Control Module (CCM) >> Identification Of The Damper Motor Module (DMM), Lin Bus 2
April 5, 2026: LEMON Manuals is launched! Read the announcement.

Identification Of The Damper Motor Module (DMM), Lin Bus 2

The parameter indicates the status after identification of the damper motors.

Temporary ID not OK = the climate control module (CCM) has been unable to allocate the damper motors a temporary ID during identification.

Defroster not OK = failed identification of the damper motor module (DMM) defroster.

Recirculation not OK = failed identification of the damper motor module (DMM) recirculation.

Temperature left not OK = failed identification of the damper motor module (DMM) temperature left.

Temperature right not OK = failed identification of the damper motor module (DMM) temperature right.

Air distribution not OK = failed identification of the damper motor module (DMM) air distribution.

OK = identification OK.