Home >> Volvo >> 2009 >> C30 R-Design, Automatic >> Repair and Diagnosis >> Transmission >> Automatic Trans >> Transmission Control Module (TCM) - Specifications, Electrical/Electronic >> Transmission Control Module (TCM) >> Component Resistance Values >> Linear Pressure Solenoid SLT, SLS/Lock-Up Solenoid SLU
October 30: LEMON manuals on a temporary server, it is slow and having issues, download the manuals you need! Later in November we will switch back to the fast server.

Linear Pressure Solenoid SLT, SLS/Lock-Up Solenoid SLU

Fig 1: Identifying Ohms Resistance Temperature Graph
GLL141942Courtesy of VOLVO CARS CORPORATION
Component  Remarks  Resistance (Ω) 
Lock-up solenoid (SLU)
Linear pressure solenoid (SLT) (SLS)
Resistance between the solenoid pins +20°C = 5.0-5.6 Ω

For other values, see diagram. When taking readings at temperatures other than +20°C, a control reading must be taken at +20°C. This is done to check whether the resistance is correct or not.