WASTEGATE Control Valve Adjustment
NOTE:
The illustrations in this service information are used for different model years and/or models. Some variation may occur. However, the essential information in the illustrations is always correct.
CHECKING OF VACUUM BOX
Remove the upper engine casing.
Remove the vacuum line from the variable turbo's vacuum box. Connect the vacuum pump. Use: see 9995843 and create underpressure of 49 cm/Hg (26 cm/Hg absolute pressure).
Measure the stroke length of the adjusting lever. If the vacuum box is intact, the stroke length should be between 11.6 and 12.8 mm, if it is not then the turbo unit should be replaced as shown: TURBOCHARGER (B5254T3; 2005-2007)
FITTING OF VACUUM HOSE
Install:
- the vacuum hose on the vacuum box
- the upper engine casing.