Home >> Volvo >> 2009 >> V70 >> Repair and Diagnosis (Single Page) >> Transmission >> Automatic Trans >> Transmission Control Module (TCM) - Specifications, Electrical/Electronic >> Component Specifications, Transmission Control Module (TCM) >> Component Specifications >> Linear Pressure Solenoid SLT, SLB1, SLC1, SLC2, SLC3 And Lock-Up Solenoid SLU
April 5, 2026: LEMON Manuals is launched! Read the announcement.

Linear Pressure Solenoid SLT, SLB1, SLC1, SLC2, SLC3 And Lock-Up Solenoid SLU

Fig 1: Identifying Ohms Resistance Temperature Graph
GLL141943Courtesy of VOLVO CARS CORPORATION
Component  Note  Resistance (Ω) 
Lock-up solenoid (SLU)
Line pressure solenoids (SLT), (SLB1),(SLC1),(SLC2),(SLC3)
Resistance between solenoid pins. +20 °C= 5.0-5.6 Ω

Other values, see diagram. When measuring at other temperature than +20 °C the check-measurement shall be performed at +20 °C. This is to ensure if the resistance is correct or not.