Checking The Component And Wiring
- Ignition off
- Disconnect the connector for the overheat protection thermostat.
Check the terminals. Check for contact resistance. Check for loose connections. Check for oxidation.
Check the resistance of the overheat protection thermostat.
Check the cable between control module terminal #5 and the terminal for the overheat protection thermostat. Check for a short-circuit to ground.
Check the cable between control module terminal #6 and the terminal for the overheat protection thermostat. Check for a short-circuit to ground.
Remedy as necessary.
Other information
- Continue
Refer to VERIFICATION