ECM-P062001: Generator Control Circuit. General Failure Information. General Electrical Failure (B6324S; 2007-2009): Fault-Tracing: Verification: Verification
HINT: After carrying out the repair, check that the fault has been remedied.
- Ignition off
- Reinstall the connectors, components etc.
- Start the engine.
- Read off the battery voltage.
- Load the battery by switching on several power consumers with a high power consumption, for example, the blower, main beam, etc.
Read off the battery voltage by clicking on the symbol for VCT2000 in VIDA (Volvo scan tool).
Check that the battery voltage is correct, battery voltage shall be approx. 13-14 V. Test at different engine speeds.
Is the function OK?
- YES
VERIFIED: Troubleshooting has been completed.
- NO
Refer to INFORMATION