Home >> Volvo >> 2010 >> XC90 Base, AWD >> Repair and Diagnosis (Single Page) >> Restraints >> Passive Restraints >> Occupant Weight Sensor (OWS) And Supplemental Restraint System Module (SRS) - Signal Specification >> Signal Specification, Occupant Weight Sensor (OWS) (2005-2014) >> Signal Specification
April 5, 2026: LEMON Manuals is launched! Read the announcement.

Signal Specification

All values specified below are between the relevant terminal and terminal #9 (power ground).

U= DC voltage in volts (V)
Ubat = Battery voltage (V)
Ulow = Voltage approximately 0 V
Fig 1: Identifying 10-Pin Connector
GLL147439Courtesy of VOLVO CARS CORPORATION
TABLE OF SIGNALS, 10-PIN CONNECTOR

Terminal number  Connector marking  Signal type  Ignition off  Ignition on  Other 
#1 F - - - -
#2 G Power supply, occupant weight sensor (OWS) Ubat for approximately 1 minute after the ignition key is moved to position 0 (applies only if the driver's door and front passenger door are closed). Ubat for approximately 5 minutes (applies if the driver's or front passenger door are opened and left open). Otherwise U low . U bat -
#3 H Signal ground, pressure sensor U low U low -
#4 J Power supply, pressure sensor 4.8-5.2 V for approximately 1 minute after the ignition key is moved to position 0 (applies only if the driver's door and front passenger door are closed). 4.8-5.2 V for approximately 5 minutes (applies if the driver's or front passenger door are opened and left open). Otherwise U low . 4.8-5.2 V -
#5 K Signal, pressure sensor - - -
#6 A Signal, seat belt force sensor - - -
#7 B Voltage supply, seat belt force sensor 4.8-5.2 V for approximately 1 minute after the ignition key is moved to position 0 (applies only if the driver's door and front passenger door are closed). 4.8-5.2 V for approximately 5 minutes (applies if the driver's or front passenger door are opened and left open). Otherwise U low . 4.8-5.2 V -
#8 C Signal ground, seat belt force sensor U low U low -
#9 D Power ground, occupant weight sensor (OWS) U low U low -
#10 E LIN bus - - During communication the voltage is 0-U bat V.