Home >> Volvo >> 2011 >> XC60 3.2 R-Design >> Repair and Diagnosis (Single Page) >> Accessories & Equipment >> Communication Devices >> Media, Communication And Navigation - Specifications, Electrical/Electronic >> Signal Specification, Phone Module >> Signal Specification, Phone Module (PHM) [2009-2017] >> Signal Specification
April 5, 2026: LEMON Manuals is launched! Read the announcement.

Signal Specification

General 

All the values given below are between the respective terminal in column 1 and terminal #C1-6 in column 2 (power ground) unless otherwise stated in parenthesis after the table entry.

NOTE:

It is important to connect the breakout box and check the ground connections before starting to measure.

There may be several connections and connectors between the control module and components. For more information about these, see the appropriate Wiring diagram.

U = DC voltage in volts (V) UAC = AC voltage in volts (V)
Ubat = Battery voltage (V) f = Frequency in Hertz (Hz)
Ulow = Voltage approximately 0 V t = Time in seconds
PWM = Pulse width modulated signal as a %    
GLL104034Courtesy of VOLVO CARS CORPORATION
SIGNAL TABLE, CONNECTOR C1

Breakout box terminal  Control module terminal  Signal type  Ignition on  Idle  Miscellaneous 
#1 #C1:1 Activation signal and diagnostic signal for ON CALL and SOS switch Not depressed = 5 V
Depressed ON CALL = approx. 1.5 V
Depressed SOS = 0.9 V
Not depressed = 5 V
Depressed ON CALL = approx. 1.5 V
Depressed SOS = 0.9 V
Only Volvo On Call
#2 #C1:2 Diagnostic signal for switch ON CALL and SOS U= 4.50-4.75 V U= 4.50-4.75 V Only Volvo On Call
#3 #C1:3 Voltage supply, SOS switch illumination U= 0-12 V U= 0-12 V Only Volvo On Call
#4 #C1:4 Voltage supply, ON CALL switch illumination U= 0-12 V U= 0-12 V Only Volvo On Call
#5 #C1:5 +30-feed U = Ubat U = Ubat -
#6 #C1:6 Power ground U=Ulow U=Ulow -
#7 #C1:7 Secrecy phone, voltage feed (does not apply to S60 11-) U = Ubat U = Ubat -
#8 #C1:8 Secrecy phone, hanger signal (does not apply to S60 11-)     Difficult to measure
#9 #C1:9 - - - -
#10 #C1:10 - - - -
#11 #C1:11 CAN (L) U = 1.5 - 2.5 V U = 1.5 - 2.5 V During communication
#12 #C1:12 CAN (H) U = 2.0 - 3.5 V U = 2.0 - 3.5 V During communication
#13 #C1:13 Signal ground, switch ON CALL and SOS U=Ulow U=Ulow Only Volvo On Call
#14 #C1:14 Signal ground, auxiliary microphone U=Ulow U=Ulow Only Volvo On Call
#15 #C1:15 Signal, spare microphone U = 5 V U = 5 V Only Volvo On Call
#16 #C1:16 - - - -
#17 #C1:17 Impact cable from SRS Pulse width modulated signal = 50%
Normal value f = 9-11 Hz
Collision registered f = 250 Hz for up to 5 seconds
Pulse width modulated signal = 50%
Normal value f = 9-11 Hz
Collision registered f = 250 Hz for up to 5 seconds
-
#18 #C1:18 Secrecy phone, ground (does not apply to S60 11-) U=Ulow U=Ulow -
#19 #C1:19 Secrecy phone, microphone signal (does not apply to S60 11-) Alternating voltage at sound in microphone Alternating voltage at sound in microphone Difficult to measure
#20 #C1:20 Secrecy phone, speaker signal (does not apply to S60 11-) Alternating voltage at sound in speaker Alternating voltage at sound in speaker Difficult to measure
#21 #C1:21 - - - -
#22 #C1:22 - - - -
GLL139873Courtesy of VOLVO CARS CORPORATION
SIGNAL TABLE, CONNECTOR C2

Breakout box terminal  Control module terminal  Signal type  Ignition on  Idle  Miscellaneous 
- #C2:1 Signal, telephone antenna Antenna signal Antenna signal -
- #C2:2 Ground, telephone antenna U=Ulow U=Ulow -
GLL101506Courtesy of VOLVO CARS CORPORATION
SIGNAL TABLE, CONNECTOR C3

Breakout box terminal  Control module terminal  Signal type  Ignition on  Idle  Miscellaneous 
#21 #C3:1 Clock signal to SIM-card Digital signal Digital signal -
#22 #C3:2 Signal ground, SIM-card U=Ulow U=Ulow -
#23 #C3:3 Voltage feed, SIM-card     -
#24 #C3:4 Communication cable, SIM-card Digital signal Digital signal -
#25 #C3:5 Control signal, SIM-card Digital signal Digital signal -
#26 #C3:6 Diagnostic cable, SIM-card Digital signal Digital signal 0 = SIM holder inserted = 1057 Ω
1 = SIM holder missing = 0 Ω
GLL108089Courtesy of VOLVO CARS CORPORATION
SIGNAL TABLE, CONNECTOR C4

Breakout box terminal  Control module terminal  Signal type  Ignition on  Idle  Miscellaneous 
- #C4:1 MOST input signal Optical input signal when the MOST network is activated Optical input signal when the MOST network is activated -
- #C4:2 MOST signal Optical output signal when the MOST network is activated Optical output signal when the MOST network is activated -
GLL139873Courtesy of VOLVO CARS CORPORATION
SIGNAL TABLE, CONNECTOR C5

Breakout box terminal  Control module terminal  Signal type  Ignition on  Idle  Miscellaneous 
- #C5:1 Signal, GPS antenna Antenna signal Antenna signal -
- #C5:2 Ground, GPS antenna U=Ulow U=Ulow -
GLL104030Courtesy of VOLVO CARS CORPORATION
SIGNAL TABLE, CONNECTOR SECRECY PHONE (DOES NOT APPLY TO S60 11-)

Breakout box terminal  Control module terminal  Signal type  Ignition on  Idle  Miscellaneous 
#22 #1 Handset, microphone signal Alternating voltage at sound in microphone Alternating voltage at sound in microphone Difficult to measure
#23 #2 Handset, speaker signal Alternating voltage at sound in speaker Alternating voltage at sound in speaker Difficult to measure
#24 #4 Handset, cradle signal     Difficult to measure
#25 #3 Handset, ground U=Ulow U=Ulow -
#26 #5 Handset, voltage feed U= approx. 10 V U= approx. 10 V -
GLL139890Courtesy of VOLVO CARS CORPORATION
SIGNAL TABLE, CONNECTOR VOLVO ON CALL SWITCH

Breakout box terminal  Control module terminal  Signal type  Ignition on  Idle  Miscellaneous 
#13 #1 Signal, spare microphone U = 5 V U = 5 V -
#14 #2 Signal ground, auxiliary microphone U=Ulow U=Ulow -
#15 #3 Voltage supply, SOS switch illumination U= 0-12 V U= 0-12 V -
#16 #4 Voltage supply, ON CALL switch illumination U= 0-12 V U= 0-12 V -
#17 #5 Activation signal and diagnostic signal for ON CALL and SOS switch Not depressed = 5 V
Depressed ON CALL = approx. 1.5 V
Depressed SOS = 0.9 V
Not depressed = 5 V
Depressed ON CALL = approx. 1.5 V
Depressed SOS = 0.9 V
-
#18 #6 Diagnostic signal for switch ON CALL and SOS U= 4.50-4.75 V U= 4.50-4.75 V -
#19 #7 Signal ground, switch ON CALL and SOS U=Ulow U=Ulow -