Home >> Volvo >> 2011 >> XC60 3.2 R-Design >> Repair and Diagnosis (Single Page) >> Transmission >> Automatic Trans >> Transmission - Specifications, Electrical/Electronic >> Component Specifications, Transmission Control Module >> Component Specifications, Transmission Control Module (TCM) [2015-2016, B5254T12, TF-80SC AWD | 2011-2016, B6304T4, TF-80SC AWD | 2011-2014, B6324S4; B6324S5, TF-80SC | 2011-2015, B6324S4; B6324S5, TF-80SC AWD] >> Component Specifications
April 5, 2026: LEMON Manuals is launched! Read the announcement.

Component Specifications

SHIFT SOLENOIDS 

GLL173489Courtesy of VOLVO CARS CORPORATION
Component  Note  Resistance (Ω) 
Gear shift solenoid S1, S2 Resistance between the solenoid pins and the solenoid casing/transmission housing. +20°C = 11-15 Ω

Other values, see diagram. When measuring at other temperature than +20 °C the check-measurement shall be performed at +20 °C. This is to ensure if the resistance is correct or not.

LINEAR PRESSURE SOLENOID SLT AND LOCK-UP SOLENOID SLU 

GLL173491Courtesy of VOLVO CARS CORPORATION
Component  Note  Resistance (Ω) 
Lock-up solenoid (SLU)
Linear pressure solenoid (SLT)
Resistance between solenoid pins. +20 °C= 5.0 - 5.6 Ω

Other values, see diagram. When measuring at other temperature than +20 °C the check-measurement shall be performed at +20 °C. This is to ensure if the resistance is correct or not.

LINEAR PRESSURE SOLENOID SLB1, SLC1, SLC2, SLC3 

GLL173490Courtesy of VOLVO CARS CORPORATION
Component  Note  Resistance (Ω) 
Linear pressure solenoid (SLB1), (SLC1), (SLC2), (SLC3) Resistance between solenoid pins. +20 °C= 5.0 - 5.6 Ω

Other values, see diagram. When measuring at other temperature than +20 °C the check-measurement shall be performed at +20 °C. This is to ensure if the resistance is correct or not.

OIL TEMPERATURE SENSOR 

GLL141860Courtesy of VOLVO CARS CORPORATION
Component  Note  Resistance (Ω) 
Oil temperature sensor Resistance between the temperature sensor terminals. +10 °C = 5587 - 7303 Ω
+25 °C≈ 3500 Ω
+110 °C = 223 - 271 Ω

Resistance decreases with increasing temperature.

A test measurement must be taken at both temperatures. This is to establish if the resistance is correct or not.

SOLENOID P-POSITION LOCKOUT 

GLL154583Courtesy of VOLVO CARS CORPORATION
Component  Note  Resistance (Ω) 
Solenoid p-position lockout Resistance between the solenoid's connections +20°C = 35-37 Ω