Parameters, Value
EVAPORATOR TEMPERATURE SENSOR.
Measurement range: -40 to 70 °C.
Measures the temperature in the evaporator.
PASSENGER COMPARTMENT TEMPERATURE SENSOR
Measurement range: -40 to +100 °C.
Measures the temperature of the air that the passenger compartment temperature sensor fan blows on the sensor.
OUTSIDE TEMPERATURE
Measurement range: -40 to +250 °C.
The value shows the outdoor temperature. The Climate control module (CCM) obtains the value via the CAN network from the central electronic module (CEM).
PASSENGER COMPARTMENT TEMPERATURE SENSOR FAN, VOLTAGE
Measures the voltage, in volts, of the fan for the passenger compartment temperature sensor.
TEMPERATURE SETTING, LEFT
Measurement range: 16 to 28 °C.
Indicates the set temperature for the left-hand side of the passenger compartment.
TEMPERATURE SETTING, RIGHT
Measurement range: 16 to 28 °C.
Indicates the set temperature for the right-hand side of the passenger compartment.
REQUESTED BLOWER FAN SPEED
Measurement range 0 to 100%.
Measures the speed of the blower fan relative to the maximum speed, 3700 rpm.
NUMBER OF COLD ZONE ACTIVATIONS
Measurement range: 0 to 1024.
Measures the number of times that the engine control module (ECM) has activated the cooling control function of cold zone.
VOLTAGE SUPPLY CONTROL MODULE
Measurement range: 0 to +25.5 V.
Measures the climate control system's supply voltage.