Component Specifications
SHIFT SOLENOIDS
| Component | Note | Resistance (Ω) |
| Gear shift solenoid S1, S2 | Resistance between the solenoid pins and the solenoid casing/transmission housing. | +20°C = 11-15 Ω |
Other values, see diagram. When measuring at other temperature than +20 °C the check-measurement shall be performed at +20 °C. This is to ensure if the resistance is correct or not.
LINEAR PRESSURE SOLENOID SLT AND LOCK-UP SOLENOID SLU
| Component | Note | Resistance (Ω) |
| Lock-up solenoid (SLU) Linear pressure solenoid (SLT) |
Resistance between solenoid pins. | +20 °C= 5.0 - 5.6 Ω |
Other values, see diagram. When measuring at other temperature than +20 °C the check-measurement shall be performed at +20 °C. This is to ensure if the resistance is correct or not.
LINEAR PRESSURE SOLENOID SLB1, SLC1, SLC2, SLC3
| Component | Note | Resistance (Ω) |
| Linear pressure solenoid (SLB1), (SLC1), (SLC2), (SLC3) | Resistance between solenoid pins. | +20 °C= 5.0 - 5.6 Ω |
Other values, see diagram. When measuring at other temperature than +20 °C the check-measurement shall be performed at +20 °C. This is to ensure if the resistance is correct or not.
OIL TEMPERATURE SENSOR
| Component | Note | Resistance (Ω) |
| Oil temperature sensor | Resistance between the temperature sensor terminals. | +10 °C = 5587 - 7303 Ω |
| +25 °C≈ 3500 Ω | ||
| +110 °C = 223 - 271 Ω |
Resistance decreases with increasing temperature.
A test measurement must be taken at both temperatures. This is to establish if the resistance is correct or not.
SOLENOID P-POSITION LOCKOUT
| Component | Note | Resistance (Ω) |
| Solenoid p-position lockout | Resistance between the solenoid's connections | +20°C = 35-37 Ω |