Home >> Volvo >> 2011 >> XC60 R-Design, FWD >> Repair and Diagnosis (Single Page) >> Transmission >> Transmission Control Systems >> Transmission - Specifications, Electrical/Electronic >> Component Specifications, Transmission Control Module >> Component Specifications, Transmission Control Module (TCM) [2014-2017, TG-81SC | 2016-2017, TG-81SC AWD] >> Component Specifications, Transmission Control Module (TCM)
April 5, 2026: LEMON Manuals is launched! Read the announcement.

Component Specifications, Transmission Control Module (TCM)

GEAR SHIFT SOLENOIDS S1, S2 

GLL173489Courtesy of VOLVO CARS CORPORATION
Component  Note  Resistance (Ω) 
Gear shift solenoid S1, S2 Resistance between the solenoid pins and the solenoid casing/transmission housing. +20 °C = 11-15 Ω

See the diagram for other values. When measuring at temperatures other than +20 °C, a test measurement must be taken at +20 °C. This is to establish if the resistance is correct or not.

LINEAR PRESSURE SOLENOIDS SLT, LOCK-UP SOLENOID SLU, AND ELECTROMAGNETIC OIL PUMP EMOP 

GLL173491Courtesy of VOLVO CARS CORPORATION
Component  Note  Resistance (Ω) 
Linear pressure solenoid SLT
Lock-up solenoid SLU
Electromagnetic oil pump EMOP
Resistance between solenoid pins. +20 °C = 5.0 - 5.6 Ω

See the diagram for other values. When measuring at temperatures other than +20 °C, a test measurement must be taken at +20 °C. This is to establish if the resistance is correct or not.

LINEAR PRESSURE SOLENOIDS SL1, SL2, SL3, SL4, SL5 

GLL173490Courtesy of VOLVO CARS CORPORATION
Component  Note  Resistance (Ω) 
Linear pressure solenoids SL1, SL2, SL3, SL4, SL5 Resistance between solenoid pins. +20 °C= 5.0 - 5.6 Ω

See the diagram for other values. When measuring at temperatures other than +20 °C, a test measurement must be taken at +20 °C. This is to establish if the resistance is correct or not.

OIL TEMPERATURE SENSOR 

GLL1026341Courtesy of VOLVO CARS CORPORATION
Component  Note  Resistance (Ω) 
Oil temperature sensor Resistance between the temperature sensor terminals. -30 °C = 3590 - 5210 Ω
+10 °C = 5587 - 7303 Ω
+25 °C≈ 3500 Ω
+40 °C = 1800 - 2200 Ω
+60 °C = 900 - 1100 Ω
+80 °C = 450 - 550 Ω
+110 °C = 223 - 71 Ω

Resistance decreases with increasing temperature.

The measurement test should be performed at both temperatures to ensure that the resistance is correct.

SOLENOID P-POSITION LOCKOUT 

GLL154583Courtesy of VOLVO CARS CORPORATION
Component  Note  Resistance (Ω) 
Solenoid p-position lockout Resistance between the solenoid's connections +20°C = 35-37 Ω