Checking The Control Module For Open-Circuits
- Remove the relay, 2/67 (2/87 5DRS).
Check the driver circuit for the relay coil for an open-circuit as follows: activate the relay driver. Measure the voltage between terminals #1 and #2 on the relay base.
HINT: The voltage between terminals #1 and #2 should be battery voltage.
HINT: If the value deviates excessively, check the voltage between terminal #2 and battery voltage and between terminal #1 and ground. Both should equal battery voltage.
HINT: Check for an open-circuit.
HINT: Do not forget to check that the power supply to the control module is OK.
Other information
Was a fault detected?
- YES
Refer to VERIFICATION
- NO