Signal Description
All the values given below are measured between the respective connection in column 1 and connection 14 (signal ground) if not otherwise specified.
NOTE:
It is important that the test box is connected and the ground points checked before testing begins.
| U = | DC voltage (V) | f = | frequency in Hertz (Hz) | |
| Ubat = | battery voltage (V) | t = | period time in milliseconds (ms) | |
| Ulow = | Voltage close to 0 V | - | ||
| Connect the test box | Connect. | Signal type | Ignition on | Idle |
|---|---|---|---|---|
| 43 | 1 | Power supply Ext X | U=Ubat | |
| 44 | 2 | Communication wire control units (CANH) | U=2.5-3.5 V | |
| 45 | 3 | Communication wire control units (CANL) | U=1.5-2.5 V | |
| 46 | 4 | Background lamp signal | Lamp off: U=Ubat Lamp on: U=Ulow |
|
| 47 | 5 | Brake fluid level signal (+) | Lamp off: U=Ubat Lamp on: U=Ulow |
|
| 48 | 6 | Parking brake signal (+) | Lamp off:U=Ubat Lamp on:U=Ulow |
|
| 49 | 7 | - | - | - |
| 50 | 8 | Communication wire control units (CANH) | U= 2.5-3.5 V | |
| 51 | 9 | Communication wire control units (CANL) | U=1.5-2.5V | |
| 52 | 10 | - | - | - |
| 53 | 11 | - | - | - |
| 54 | 12 | - | - | - |
| 55 | 13 | - | - | - |
| 56 | 14 | Signal ground | U=Ulow | |