Home >> Volvo >> 2012 >> XC90 R-Design, FWD >> Repair and Diagnosis (Single Page) >> Heating, Ventilation & A/C (HVAC) >> HVAC Control Systems >> Climate Units - Specifications, Electrical/Electronic >> Signal Specification, Climate Control Module (CCM) (2003-2004) >> Signal Specification >> Signal Description, Climate Control Module (CCM), Connector C
April 5, 2026: LEMON Manuals is launched! Read the announcement.

Signal Description, Climate Control Module (CCM), Connector C

There is no breakout box for this connector.

NOTE: From and including w50 2001, the fan is connected directly to connector C with no wiring in-between.
U= DC voltage in volts (V) UAC = AC voltage in volts (V)
Ubat = Battery voltage (V) f = Frequency in Hertz (Hz)
Ulow = Voltage approximately 0 V % duty = Duty cycle (pulse ratio) as a percentage (%)
t = Time in milliseconds (ms) - -
Control module terminal Connecting the component Signal type Ignition on Engine idling Other
#C1 terminal #1 Hall sensor Power supply (H+), Hall sensor 6.1-6.3 V 6.1-6.3 V -
#C2 terminal #2 Hall sensor Signal (H1), Hall sensor 3.7 V 3.7 V -
#C3 terminal #3 fan motor passenger compartment temperature sensor Signal, fan motor passenger compartment temperature sensor 1-5.2 V 1-5.2 V Quadratic signal when the motor is running
#C4 terminal #4 fan motor passenger compartment temperature sensor Signal, fan motor passenger compartment temperature sensor 1-5.2 V 1-5.2 V Quadratic signal when the motor is running
#C5 terminal #5 Hall sensor Signal ground (H-), Hall sensor 0.9-1.6 V 0.9-1.6 V -
#C6 terminal #6 Hall sensor Signal (H2), Hall sensor 3.7 V 3.7 V -