Line Pressure Solenoid STH Amperage
The value indicates the amperage passing through the solenoid circuit. A lower amperage gives a higher reference pressure, which gives a higher line pressure. Solenoid control is directly dependent on the throttle sensor signal. The higher the signal from the throttle sensor the lower the amperage through the solenoid and therefore the higher the line pressure.
Measurement range: 0.0 -1.5 A
Normal value at closed throttle: 280 mA