Checking For An Open-Circuit
Check the cable between the control module terminal #19 and roof lamp module terminal #5A. Check for an open-circuit. Check for a short-circuit to supply voltage.
Replace the cable if a fault is found.
If no fault was found, try replacing the lamps.
Other information:
- For further information about signals and other values, see SIGNAL DESCRIPTION, UPPER ELECTRONIC MODULE (UEM)
- To connect the breakout box, see CONNECTING THE BREAKOUT BOX
- To replace the lamps, see INTERIOR LIGHTING, REPLACING
- see CHECKING WIRING AND TERMINALS .
- Continue
Refer to VERIFICATION