Coolant Pump (6/73)
GENERAL
Characteristic
- The pump cannot be measured for resistance due to the electronics inside the pump.
Other information
Current consumption:
Normal operation: 1.2 A
Max.: 1.7 A
TERMINAL
| Connector terminal | Control module terminal | Signal type | Other |
|---|---|---|---|
| #1 | #3 in 3-pin external connector | Coolant pump, control signal | - |
| #2 | #2 in 3-pin external connector | Coolant pump, ground | - |