Parameters, Status
DAMPER MOTOR RECIRCULATION
Indicates status of the selected node on LIN bus 1.
Value set:
Node not installed/initialized.
Node detected but not expected.
Node expected but not detected.
Detected as expected.
DAMPER MOTOR TEMPERATURE LEFT.
Indicates status of the selected node on LIN bus 1.
Value set:
Node not installed/initialized.
Node detected but not expected.
Node expected but not detected.
Detected as expected.
AIR DISTRIBUTION DAMPER MOTOR.
Indicates status of the selected node on LIN bus 1.
Value set:
Node not installed/initialized.
Node detected but not expected.
Node expected but not detected.
Detected as expected.
SEAT HEATER, LEFT-HAND FRONT
Indicates status of the selected node on LIN bus 1.
Value set:
Node not installed/initialized.
Node detected but not expected.
Node expected but not detected.
Detected as expected.
SEAT HEATER, LEFT-HAND REAR
Indicates status of the selected node on LIN bus 1.
Value set:
Node not installed/initialized.
Node detected but not expected.
Node expected but not detected.
Detected as expected.
SETA HEATER REAR SWITCH
Indicates status of the selected node on LIN bus 1.
Value set:
Node not installed/initialized.
Node detected but not expected.
Node expected but not detected.
Detected as expected.
SEAT HEATER, RIGHT-HAND FRONT
Indicates status of the selected node on LIN bus 2.
Value set:
Node not installed/initialized.
Node detected but not expected.
Node expected but not detected.
Detected as expected.
SEAT HEATER, RIGHT-HAND REAR
Indicates status of the selected node on LIN bus 2.
Value set:
Node not installed/initialized.
Node detected but not expected.
Node expected but not detected.
Detected as expected.
HUMIDITY SENSOR
Indicates status of the selected node on LIN bus 2.
Value set:
Node not installed/initialized.
Node detected but not expected.
Node expected but not detected.
Detected as expected.
DAMPER MOTOR, DEFROSTER
Indicates status of the selected node on LIN bus 2.
Value set:
Node not installed/initialized.
Node detected but not expected.
Node expected but not detected.
Detected as expected.
DAMPER MOTOR, TEMPERATURE, RIGHT
Indicates status of the selected node on LIN bus 2.
Value set:
Node not installed/initialized.
Node detected but not expected.
Node expected but not detected.
Detected as expected.
STATUS, AIR QUALITY SENSOR
Indicates the status of the Air quality sensor
Level 0 = No increase or decrease in pollutant level.
Level 1 = Slow increase in pollutant level.
Level 2 = Medium increase in pollutant level.
Level 3 = Rapid increase in pollutant level.
Warm-up phase = The sensor is currently heated to function correctly.
Defective heater pad = The heater pad that heats the sensor is defective.
Stand by mode = The sensor is not active but listens to the data communication to be able to start, if necessary.
COMMUNICATION, AIR QUALITY SENSOR
Indicates the communication status of the sensor.
OK = Communication OK.
Not OK = Communication not OK.
AUTO DEFROSTER REAR WINDSHIELD
Indicates the status of the Auto defroster in the rear windshield.
Off = The function is inactive.
ON = The function is active.