Removal Procedure

1. Disable the hybrid battery. Refer to High Voltage Disabling High Voltage Disabling.





2. Remove the drive motor battery cooling blower outlet duct fasteners (1).

3. Detach the drive motor cooling blower outlet duct. Refer to Drive Motor Battery Cooling Blower Outlet Duct Replacement Drive Motor Battery Cooling Blower Outlet Duct Replacement.





4. Remove the generator control module cooling air outlet duct fasteners (1) and remove the generator control module cooling air outlet duct (2).

Installation Procedure





Caution:
Refer to Fastener Caution Fastener Caution.

1. Install the generator control module cooling air outlet duct (2) and tighten the fasteners (1) to 9 Nm (80 lb in).





2. Install the drive motor battery cooling blower outlet duct (2) and tighten the fasteners (1) to 9 Nm (80 lb in).

3. Enable the hybrid battery. Refer to High Voltage Enabling High Voltage Enabling.