Rectifier Diodes
Check continuity between rectifier assembly terminals "E" and P1-P4. See Fig 1. Note ohmmeter reading. Reverse leads, and repeat test. Continuity should only be present in one direction. If continuity is not as specified, replace rectifier assembly.