Outside Air Temperature Sensor Test
NOTE:
before testing the sensor, check for HVAC DTCs (see
GENERAL TROUBLESHOOTING INFORMATION )
- Remove the outside air temperature sensor (see Outside Air Temperature Sensor Replacement )
- Dip the sensor in ice water, and measure the resistance Then pour warm water on the sensor, and check for a change in resistance
- Compare the resistance reading between terminals No 1 and No 2 of the outside air temperature sensor with the specifications shown in the graph, the resistance should be within the specifications
- If the resistance is not as specified, replace the outside air temperature sensor (see Outside Air Temperature Sensor Replacement )