Mode Control Motor Test
NOTE:
Before testing, check for climate control DTCs (see HOW TO CHECK FOR DTCS WITH THE HDS
).
- Disconnect the 5P connector from the mode control motor.NOTE: Incorrectly applying power and ground to the mode control motor will damage it. Follow the instructions carefully.
- Connect battery power to terminal No. 1 of the mode control motor, and ground terminal No. 2; the mode control motor should run smoothly, and stop at Vent. If it does not, reverse the connections; the mode control motor should run smoothly, and stop at Defrost. When the mode control motor stops running, disconnect battery power immediately.
- If the mode control motor did not run in step 2, remove it, then check the mode control linkage and the doors for smooth movement.
- If the linkage and the doors move smoothly, replace the mode control motor (see MODE CONTROL MOTOR REPLACEMENT ).
- If the linkage or the doors stick or bind, repair them as needed.