Injector Operation
- Remove fuel rail assembly, with injectors, from intake manifold. Attach jumper wire between terminals 5 and 6 of diagnostic connector D1.
- Briefly apply 12V power and ground to 1 injector at a time. Injector should spray fuel and cut off cleanly when power is removed. If not, replace faulty injector.