General Service
Capacity - 1 qt.
Lubricant - ATF Dexron or Dexron II
Oil Level Check - Remove reservoir cover, start engine and check fluid level. Fluid level should be at mark on upper inside of reservoir.
Hydraulic System Bleeding - Start engine and allow to idle. Check that fluid is at proper level. Turn steering wheel lock to lock several times quickly. Continue until fluid level remains at reservoir mark. Make sure that no bubbles appear in reservoir when steering wheel is turned. Shut off engine and check that oil level does not rise more than 3/8" above mark.
Oil Filter Replacement - Remove outer cover, gasket and spring from reservoir. Remove inner filter cover and filter insert. Replace filter. Install new filter, replace filter cover, spring, gasket and cover. Check fluid level.