Resistance Checking

Disconnect negative battery cable. Disconnect Blue wire terminal of alternator. Connect Multimeter (US 1119 ) between Blue wire and battery positive. Turn ignition on. If readings is not 140-160 ohms, replace instrument cluster printed circuit and recheck.

Fig 1: Exploded View of Bosch 110-Amp Alternator
G29437