Throttle Position (TP) Sensor
TP sensor is connected to throttle shaft and is supplied 5 volts by MFI ECM. MFI ECM receives a varying voltage signal from TP potentiometer as throttle position changes. Voltage signal supplied MFI ECM is used to determine position of throttle plates and speed of throttle movement. This data is used for:
- Acceleration enrichment
- Full throttle enrichment.
Throttle valve potentiometer is also used as a substitute for Mass Airflow (MAF) sensor.