Auto Closing System
NOTE:
All power windows MUST operate when switches are operated manually before proceeding with this test.
- Turn ignition switch off. Remove control module from auxiliary relay panel, located behind left side kick panel. Measure voltage between terminals No. 1 and 2 at relay socket "A". See Figure . If battery voltage does not exist, go to next step. If battery voltage does not exist, repair wiring. See WIRING DIAGRAMS.
- Measure voltage between terminals No. 1 and 2 at relay socket "A". Using key, turn door lock cylinder to unlock position and hold. If battery voltage exists, install power window/sun roof relay control module and go to next step. If battery voltage does not exist, check wiring between lock cylinder and control module. See WIRING DIAGRAMS. If wiring is okay, replace lock cylinder.
- Remove automatic window closing relay. Measure voltage between terminals No. 5 and 8 at relay socket "C". If battery voltage exists, replace automatic window closing relay. If battery voltage does not exist, repair wiring. See WIRING DIAGRAMS.