Adaptation Of Throttle Valve Control Module

Throttle Valve Control Module (TVCM) teaches ECM various positions of throttle valve when ignition is on. Throttle positions are stored in the ECM in the form of voltage values. Throttle position is communicated to ECM through 2 angle sensors in TVCM.

TVCM adaptation must be performed when voltage supply to TVCM or ECM is lost, or if either module is replaced. Adaptation required is recognized if stored values from angle sensors does not match actual measured voltages. TVCM adaptation occurs:

NOTE: Engine will not start during automatic adaptation. Ignition must remain on for entire adaptation procedure. Ensure coolant temperature and intake air temperature are between 50-194° F (10-90° C). Battery voltage is 12.7 volts or more.

Connect VAS 5051 or equivalent scan tool to DLC. DLC is located behind cover under left side of steering column. Using scan tool check and clear any DTCs in memory. See RETRIEVING DIAGNOSTIC TROUBLE CODES . Using VAS 5051, from selection 1 click on function "04 - BASIC SETTING. Follow scan tool instructions to enter BASIC SETTING function. From BASIC SETTING function, select "DISPLAY GROUP NUMBER 060". Press "Q" button to confirm input. Follow scan tool instructions for TVCM adaptation. ECM will abort adaptation if: throttle valve cannot be closed completely (e.g. dirty throttle body), battery voltage is too low, engine is started or accelerator pedal is pressed during adaptation or throttle valve housing bolts are loose.

After termination, if scan tool displays "FUNCTION IS UNKNOWN OR CANNOT BE PERFORMED AT THE MOMENT". Next time ignition is switched on, adaptation will be automatically repeated. End function "04 - BASIC SETTING" by pressing "BACK ARROW" button on scan tool.