LEMON Manuals: Even more car manuals for everyone: 1960-2025
Home >> Audi >> 2004 >> S6 V8-4.2L (BBD) >> Repair and Diagnosis >> Body and Frame >> Seats >> Testing and Inspection >> Scan Tool Testing and Procedures >> Driver's Seat Adjustment W/Memory Control Module, OBD >> Measuring Value Blocks (Function 08) >> Reading
April 5, 2026: LEMON Manuals is launched! Read the announcement.

Reading




Read Measuring Value Block (Function 08)


NOTE:
"Read Measuring Value Block" function can be used to establish the current system status.


Implementing function "08 - Read Measuring Value Block"

Indicated on display:

Rapid data transfer HELP
Select function XX



- Press keys 0 and 8.

Indicated on display:


Rapid data transfer Q
08 - Rapid Measuring Value Block



- Confirm entry with Q key.

Indicated on display:


Read Measuring Value Block
Enter display group number XXX



- Enter display group number 001 and confirm entry with Q key.

The measuring value block selected is then displayed in standardized form. Evaluation. Evaluating Measured Value Blocks