LEMON Manuals: Even more car manuals for everyone: 1960-2025
Home >> Audi >> 2004 >> TT Base, 2D Convertible >> Repair and Diagnosis >> Engine Performance >> System >> 1.8L - Turbo Fuel Injection & Ignition, Engine Code(S): AWP >> 01 On Board Diagnostic (OBD) >> Readiness code >> Read readiness code
April 5, 2026: LEMON Manuals is launched! Read the announcement.

Read readiness code

Test sequence 

Fig 1: Diagnostic System VAS 5051: Display
GW00006284Courtesy of VOLKSWAGEN UNITED STATES, INC.

Display on VAS 5051:

Fig 2: Diagnostic System VAS 5051: Display - Display Group And Key Pad
GW00006285Courtesy of VOLKSWAGEN UNITED STATES, INC.

Display on VAS 5051:

1 - Enter display group

(figures up to 255)

Fig 3: Diagnostic System VAS 5051: Display - Display Fields
GW00015747Courtesy of VOLKSWAGEN UNITED STATES, INC.

Display on VAS 5051:

  Display zones 
  1 2 3 4
Display group 086: Readiness code 
Display  0 0 0 0 0 0 0 0  X X X X X X X X X X X X X X X X  
Indicates  Ready-Bits 
Finalized tests 
Performed tests Performed tests  
Range  1 = not finalized 
0 = finalized 
1 = not finalized
0 = finalized
1 = not finalized
0 = finalized
 
Specification  0 0 0 0 0 0 0 0  X X X X X X X X X X X X X X X X  
Note  Significance of readiness code. Refer to Readiness code   

Note on display zone 1: 

Display zone 1 is of main importance. This display indicates which component was tested by On Board Diagnostic since the last time the DTC memory was erased or a new control module was installed. After erasing the DTC memory, all test values (except the values which cannot be tested) are set to "1". After performing the test procedure successfully all values are set to "0". 

Notes on Display group 086, Display zone 1
                Diagnosis of catalytic converter
  • Display 0 = Test finalized
  • Display 1 = Test not finalized (Generating readiness code. Refer to Generate readiness code )
                Display constantly 0 
                EVAP system 
  • Display 0 = Test finalized
  • Display 1 = Test not finalized (Generating readiness code. Refer to Generate readiness code )
                Secondary air system 
  • Display 0 = Test finalized
  • Display 1 = Test not finalized (Generating readiness code. Refer to Generate readiness code )
                Display constantly 0 
                Oxygen sensors 
  • Display 0 = Test finalized
  • Display 1 = Test not finalized (Generating readiness code. Refer to Generate readiness code )
                Oxygen sensor heating 
  • Display 0 = Test finalized
  • Display 1 = Test not finalized (Generating readiness code. Refer to Generate readiness code )
                Display constantly 0 
NOTE: The readiness code has only been successfully generated if all digits in display zone 1 are set to "0".

If the specification "0 0 0 0 0 0 0 0" is attained:

If the specification is not attained: