Mass Air Flow Sensor, Checking: Notes

NOTE:

Use only gold-plated terminals when servicing terminals in harness connector of Mass Air Flow (MAF) Sensor -G70-.

Special tools and workshop equipment required 

Test requirements 

Test procedure 

-- Perform a preliminary check to verify the customers complaint. Refer to PRELIMINARY CHECK 

Start diagnosis 

-- Connect the scan tool.

-- Start engine and let it run at idle.

-- Using the scan tool, Check the air flow quantity of the Mass Air Flow (MAF) Sensor -G70- at idle:

Diagnostic text Specified value
Air flow quantity at Mass Air Flow (MAF) sensor  
  • Engine running at idle
2.00 to 5.00 g/sec

-- End diagnosis and switch ignition off.

If specified value is obtained, but DTC memory has a DTC concerning Mass Air Flow (MAF) Sensor -G70- :

-- Check voltage supply of Mass Air Flow (MAF) Sensor -G70- Checking voltage supply .

If specified value was not obtained:

-- Check the Mass Air Flow (MAF) Sensor -G70- electrical circuit Checking electrical circuit .