Testing knock sensor wiring
- Disconnect knock sensor 1 -G61- connector -Pos. 1- or knock sensor 2 -G66- connector -Pos. 4-.
NOTE:
To gain access to the connector, remove coolant expansion tank bolt -arrow- and move expansion tank to the side. Fuel hoses remain connected.
- Test for short between all three terminals in knock sensor connector (terminals 1+2, 1+3, 2+3).
- Specified value: INIFINITY Ω (no continuity) the wiring must not be connected to each other.
- If there is a connection between terminals, install a new knock sensor.
If no malfunction is found: