LEMON Manuals: Even more car manuals for everyone: 1960-2025
Home >> Audi >> 2006 >> A4 Base, 2D Convertible >> Repair and Diagnosis >> Engine Performance >> System >> 1.8L - Ignition System, Engine Code(S): AMB >> Ignition System >> Ignition system, checking >> Motronic Engine Control Module (ECM) power supply, checking >> Test sequence
April 5, 2026: LEMON Manuals is launched! Read the announcement.

Test sequence

NOTE:
  1. The positive voltage supply to the ECM is provided via terminal 3 (terminal 15) and terminal 62 (terminal 30).
  2. The ground (GND) connection to the ECM is provided via terminal 1 and terminal 2.
ECM POWER/GROUND CIRCUIT CHECK: SOCKET 1, 2, 62 MEASURE

Test box V.A.G 1598/31 Socket Measure to
1 Battery positive (B+)
2 Battery positive (B+)
62 Engine ground (GND)