Left Peripheral Camera - R244-/Right Peripheral Camera - R245-, Calibrating: Notes
WARNING: This page does not describe the selected car, but rather 9 other vehicles, including the 2018 Audi S6, 2018 Audi A6 Quattro, 2018 Audi A6, 2017 Audi S6, and 2017 Audi A6 Quattro. However, it is still accessible from the selected car via links, so may be relevant.
Special tools and workshop equipment required
- Calibration Tool - VAS6350A-
- Peripheral Camera Calibration Device - VAS6350A/6-
- Vehicle Diagnostic Tester
The Left Peripheral Camera - R244-/Right Peripheral Camera -R245- are installed inside the left and right exterior mirrors.
The following describes calibrating the Left Peripheral Camera -R244-. Calibrating the Right Peripheral Camera - R245- is identical.
- Establish the requirements. Refer to Peripheral Camera System, Calibrating .
- Install and align the -VAS6350A- with - VAS6350A/6-. Refer to Calibration Tool VAS6350A with Peripheral Camera Calibration. .
- Connect the Vehicle Diagnostic Tester.
Setting Up the Calibration Device
-VAS6350/1- installing:
- Check the dimension of the holes.
- Equip the -VAS6350/1- appropriately. Use spacer pieces.
- To do so, secure the three wheel bolt adapters in the hole circle to each -VAS6350/1-.
- Place the paddle on both -VAS6350/1- and secure them using a clamping screw.
- Place the -VAS6350/1- onto the wheel bolts on the front wheels.
The -VAS6350/1- are positioned by the "O-rings" in the adapters and secured.
NOTE:
Attach the -VAS6350/1- onto the wheels so that any installed "anti-theft" wheel bolts are not connected to the - VAS6350/1-.
- Position the equipped -VAS6350A- with the -VAS6350A/6- -4- near the vehicle.
- Adjust the paddle -2- with a clamping screw so that it moves freely and easily just over the -VAS6350A- -4- calibration platform.