Home >> Audi >> 2012 >> A7 >> Repair and Diagnosis >> External Pages >> Different car >> Section 73 (Communication System (Service Information)) >> Communication >> Peripheral Camera >> Peripheral Camera System, Calibrating >> Left Peripheral Camera -R244- /Right Peripheral Camera -R245-, CALIBRATING
April 5, 2026: LEMON Manuals is launched! Read the announcement.

Left Peripheral Camera -R244- /Right Peripheral Camera -R245-, CALIBRATING

WARNING: This page does not describe the selected car, but rather 9 other vehicles, including the 2018 Audi S7, 2018 Audi RS 7, 2018 Audi A7 Quattro, 2017 Audi S7, and 2017 Audi RS 7. However, it is still accessible from the selected car via links, so may be relevant.

Special Tools And Workshop Equipment Required 

The Left Peripheral Camera -R244- /Right Peripheral Camera -R245- are installed inside the left and right exterior mirrors.

The following describes calibrating the Left Peripheral Camera -R244-. Calibrating the Right Peripheral Camera -R245- is identical.

-- Set-up requirements Calibration Tool .

-- Install and align the :VAS6350  with : VAS6350/6  . Refer to Calibration Tool .

-- Connect the Vehicle Diagnostic Tester.

Setting Up The Calibration Device 

:VAS6350/1  installing:

-- Check the dimension of the holes.

-- Equip the :VAS6350/1  appropriately. Use spacer pieces.

-- To do so, secure three wheel bolt adapters in the hole circle to the :VAS6350/1  .

-- Position the paddle on the :VAS6350/1  and secure using the clamping screw.

-- Place the :VAS6350/1  on the wheel bolts on the left front wheel.

The :VAS6350/1  is positioned by the "O rings" in the adapters and held in place.

GWWN94-10685Courtesy of AUDI OF AMERICA, LLC
NOTE:

Attach the :VAS6350/1  onto the wheel so that any installed "anti-theft" wheel mounting bolts are not connected to the :VAS6350/1  .

-- Position the equipped :VAS6350  with the :VAS6350/6  -4- near the vehicle.

GWWA91-11965Courtesy of AUDI OF AMERICA, LLC

-- Adjust the paddle -2- with a clamping screw so that it moves freely and easily just over the :VAS6350  -4- calibration platform.

Installing the :VAS6350/3  :

-- Install the :VAS6350/6-5  -2- all the way using the 3/8" fine toothed ratchet on the left rear wheel and install the :VAS6350/6-6  together with the :VAS6350/3  -1-.

GWWA91-11904Courtesy of AUDI OF AMERICA, LLC

-- Slide the :VAS6350/6-6  so that the outer edge of the :VAS6350/6-5  is flush with the outer edge of the laser housing -arrow-. Tighten the clamping lever.

:VAS6350  with :VAS6350/6  Orientation

-- Switch on the :VAS6350/3  -3- and adjust the laser beam forward toward the :VAS6350/1  -2- such that a line appears on the :VAS6350  -4- calibration field.

GWWA91-11965Courtesy of AUDI OF AMERICA, LLC

-- Adjust the :VAS6350  -4- calibration field such that the outer edge of the black line on the :VAS6350  -4- calibration field is exactly on the laser beam.

-- Adjust the :VAS6350  -4- calibration field relative to the outer edge of the black line -1- so that it lines up exactly with the free-hanging paddle on the :VAS6350/1  -2-.

-- Bring the : VAS6350  with :VAS6350/6  into a horizontal position.

-- To do so, twist plastic feet under the calibration field of the :VAS6350  so that air bubble in level is located exactly in the center of the indicator -arrow-

GWWN94-10686Courtesy of AUDI OF AMERICA, LLC
WARNING:

Make sure light does not reflect off the :VAS6350/6  .

Reflections affect the camera and may make it impossible to perform the calibration.

Dimension Measurement -h-

-- Measure the height of the :VAS6350  -2- calibration field, dimension -h-, from the surface of the :VAS6350  -2- calibration field (not the aluminum frame) down to the floor. Measure the hole in the :VAS6350  -2- calibration field.

GWWN94-12215Courtesy of AUDI OF AMERICA, LLC

Make sure the :VAS6350/2  -1- is adjusted correctly (attach with front edge).

The display shows how to stop the :VAS6350/2  . Press the corresponding button.

GWWA91-12100Courtesy of AUDI OF AMERICA, LLC
  1. Attach with front edge
  2. Attach with rear edge

Dimension -h- and the distance dimension must now be entered into the Vehicle Diagnostic Tester in "millimeters".

Performing Calibration 

Vehicle Diagnostic Tester is attached.

-- Select the Diagnostic  mode and start the diagnostics.

-- Select the tab Test Plan  .

-- Select Select Individual Tests  and choose the following sequence.

The Vehicle Diagnostic Tester continues with the calibrating procedure from here on.

WARNING:

Make sure light does not reflect off the :VAS6350/6  .

Reflections affect the camera and may make it impossible to perform the calibration.