Rear Peripheral Camera -R246- CALIBRATING

WARNING: This page does not describe the selected car, but rather 9 other vehicles, including the 2018 Audi S7, 2018 Audi RS 7, 2018 Audi A7 Quattro, 2017 Audi S7, and 2017 Audi RS 7. However, it is still accessible from the selected car via links, so may be relevant.

The Rear Peripheral Camera -R246- is installed in the rear lid handle button.

Special Tools And Workshop Equipment Required 

-- Set-up requirements Calibration Tool .

-- Install and align the :VAS6350  with : VAS6350/6  . Refer to Calibration Tool .

-- Connect the Vehicle Diagnostic Tester.

Setting Up The Calibration Device 

:VAS6350/1  installing:

-- Check the dimension of the holes.

-- Equip the :VAS6350/1  appropriately. Use spacer pieces.

-- To do so, secure three wheel bolt adapters in the hole circle to each :VAS6350/1  .

-- Place the paddle on both :VAS6350/1  and secure them using a clamping screw.

-- Place the :VAS6350/1  onto the wheel bolts on the rear wheels.

The :VAS6350/1  are positioned by the "O rings" in the adapters and held in place.

GWWN94-10685Courtesy of AUDI OF AMERICA, LLC
NOTE:

Attach the :VAS6350/1  onto the wheels so that any installed "anti-theft" wheel mounting bolts are not connected to the :VAS6350/1  .

-- Adjust the paddle with aid of lock bolts so that they move freely just above the floor. Make sure that the paddle is easily accessible.

:VAS6350  with :VAS6350/6  Orientation

-- Position the :VAS6350  with the :VAS6350/6  -2- at a distance of between 400 mm and 600 mm -dimension B- in the rear of the vehicle in the center (in behind of the rear bumper trim).

GWWA91-12105Courtesy of AUDI OF AMERICA, LLC

-- Move the calibration field on the :VAS6350  into a horizontal position.

-- To do so, twist plastic feet under the calibration field of the :VAS6350  so that air bubble in level is located exactly in the center of the indicator -arrow-

GWWN94-10686Courtesy of AUDI OF AMERICA, LLC
WARNING:

Make sure light does not reflect off the :VAS6350/6  .

Reflections affect the camera and may make it impossible to perform the calibration.

-- Attach the :VAS6350/3  -4- to the :VAS6350  to the center of the location provided.

GWWA91-10165Courtesy of AUDI OF AMERICA, LLC

-- Switch on the :VAS6350/3  -4- on the calibration field of the :VAS6350  and align the entire :VAS6350  with :VAS6350/6  so that the laser beam of the :VAS6350/3  hits the center of vehicle rear above the Audi rings.

-- Make sure the Audi rings are centered on the rear. Correct the laser beam accordingly.

Distance Measurement 

-- Switch on the :VAS6350/2  .

GWWA91-12101Courtesy of AUDI OF AMERICA, LLC

The display shows how to stop the :VAS6350/2  . Press the corresponding button.

GWWA91-12100Courtesy of AUDI OF AMERICA, LLC
  1. Attach with front edge
  2. Attach with rear edge

-- Hold the :VAS6350/2  -2- flush in the bracket on one side of the :VAS6350  (attach with rear edge). The :VAS6350/2  -2- must sit securely on the bracket.

GWWN94-10684Courtesy of AUDI OF AMERICA, LLC

-- Press the measuring button briefly.

The laser turns on.

-- Make sure that laser beam from :VAS6350/2  -2- hits lower, enlarged part of paddle -1-.

If this is not the case, paddles must be corrected accordingly via clamping screws on the :VAS6350/1  .

-- Use one hand to secure the :VAS6350/2  in the bracket on the :VAS6350  while the laser beam is visible on the paddle.

-- Then press the measuring button for distance measurement briefly.

-- Repeat this measurement on the other side of the :VAS6350  in the same way for the rear wheel.

The distance value must be the same on both sides.

If values are not identical:

-- Align the :VAS6350  long enough so that both sides are identical.

Pay attention when aligning the calibration field of the :VAS6350  , that the :VAS6350/3  from the :VAS6350  strikes the center of the Audi rings and the indicator of the level remains centered. Adjust if necessary.

-- Make note of the distance dimension measured.

Dimension Measurement -h-

-- Measure the height of the :VAS6350  -2- calibration field, dimension -h-, from the surface of the :VAS6350  -2- calibration field (not the aluminum frame) down to the floor. Measure the hole in the :VAS6350  -2- calibration field.

GWWN94-12215Courtesy of AUDI OF AMERICA, LLC

Make sure the :VAS6350/2  -1- is adjusted correctly (attach with front edge).

The display shows how to stop the :VAS6350/2  . Press the corresponding button.

GWWA91-12100Courtesy of AUDI OF AMERICA, LLC
  1. Attach with front edge
  2. Attach with rear edge

Dimension -h- and the distance dimension must now be entered into the Vehicle Diagnostic Tester in "millimeters".

Performing Calibration 

Vehicle Diagnostic Tester is attached.

-- Select the Diagnostic  mode and start the diagnostics.

-- Select the tab Test Plan  .

-- Select Select Individual Tests  and choose the following sequence.

The Vehicle Diagnostic Tester continues with the calibrating procedure from here on.

WARNING:

Make sure light does not reflect off the :VAS6350/6  .

Reflections affect the camera and may make it impossible to perform the calibration.