Left Peripheral Camera -R244- /Right Peripheral Camera -R245-, CALIBRATING
Special tools and workshop equipment required
- Calibration ToolVAS6350
- Peripheral Camera Calibration DeviceVAS6350/6
- Vehicle Diagnostic Tester
The Left Peripheral Camera -R244- /Right Peripheral Camera -R245- are installed inside the left and right exterior mirrors.
The following describes calibrating the Left Peripheral Camera -R244-. Calibrating the Right Peripheral Camera -R245- is identical.
-- Setup requirements. Refer to Calibration Tool VAS6350 WITH Peripheral Camera Calibration Device VAS6350/6, INSTALLING AND ALIGNING .
-- Install and align the Calibration ToolVAS6350 with Peripheral Camera Calibration Device VAS6350/6. Refer to Calibration Tool VAS6350 WITH Peripheral Camera Calibration Device VAS6350/6, INSTALLING AND ALIGNING .
-- Connect the Vehicle Diagnostic Tester.
Setting up the calibration device
Calibration Tool - Wheel Center MountingsVAS6350/1 installing:
-- Check the dimension of the holes.
-- Equip the Calibration Tool - Wheel Center MountingsVAS6350/1 appropriately. Use spacer pieces.
-- To do so, secure three wheel bolt adapters in the hole circle to each Calibration Tool - Wheel Center MountingsVAS6350/1.
-- Place the paddle on both Calibration Tool - Wheel Center MountingsVAS6350/1 and secure them using a clamping screw.
-- Place the Wheel Center MountingVAS6350/1 onto the wheel bolts on the front wheels.
The Calibration Tool - Wheel Center MountingsVAS6350/1 are positioned by the "O rings" in the adapters and held in place.
Attach the Calibration Tool - Wheel Center MountingsVAS6350/1 onto the wheels so that any installed "anti-theft" wheel mounting bolts are not connected to the Calibration Tool - Wheel Center MountingsVAS6350/1.
-- Position the equipped Calibration ToolVAS6350 with the Peripheral Camera Calibration DeviceVAS6350/6 -4- near the vehicle.
-- Adjust the paddle -2- with a clamping screw so that it moves freely and easily just over the Calibration ToolVAS6350 -4- calibration platform.
Installing the Calibration Tool - Linear LaserVAS6350/3:
-- Install the Guide PinVAS6350/6-5 -2- all the way using the 3/8" fine toothed ratchet on the left rear wheel and install the Line Scan Laser MountVAS6350/6-6 together with the Left Post MountVAS6350/3 -1-.
-- Slide the Line Scan Laser MountVAS6350/6-6 so that the outer edge of the Guide PinVAS6350/6-5 is flush with the outer edge of the laser housing -arrow-. Tighten the clamping lever.
Calibration ToolVAS6350 with Peripheral Camera Calibration DeviceVAS6350/6 orientation
-- Switch on the Calibration Tool - Linear LaserVAS6350/3 -3- and adjust the laser beam forward toward the Calibration Tool - Wheel Center MountingsVAS6350/1 -2- such that a line appears on the Calibration ToolVAS6350 -4- calibration field.
-- Adjust the Calibration ToolVAS6350 -4- calibration field such that the outer edge of the black line on the Calibration ToolVAS6350 -4- calibration field is exactly on the laser beam.
-- Adjust the Calibration ToolVAS6350 -4- calibration field relative to the outer edge of the black line -1- so that it lines up exactly with the free-hanging paddle on the Calibration Tool - Wheel Center MountingsVAS6350/1 -2-.
-- Bring the Calibration ToolVAS6350 with Night Vision Calibration ToolVAS6350/6 into a horizontal position.
-- To do so, twist plastic feet under the calibration field of the Calibration ToolVAS6350 so that air bubble in level is located exactly in the center of the indicator -arrow-
Make sure light does not reflect off the Peripheral Camera Calibration DeviceVAS6350/6.
Reflections affect the camera and may make it impossible to perform the calibration.
-- Measure the height of the Calibration ToolVAS6350 -2- calibration field, dimension -h-, from the surface of the Calibration ToolVAS6350 -2- calibration field (not the aluminum frame) down to the floor. Measure the hole in the Calibration ToolVAS6350 -2- calibration field.
Make sure the Calibration Tool - Spacing LaserVAS6350/2 -1- is adjusted correctly (attach with front edge).
The display shows how to stop the Calibration Tool - Spacing LaserVAS6350/2. Press the corresponding button.
- Attach with front edge
- Attach with rear edge
Dimension -h- and the distance dimension must now be entered into the Vehicle Diagnostic Tester in "millimeters".
Performing calibration
Vehicle Diagnostic Tester is attached.
-- Select the Diagnostic mode and start the diagnostics.
-- Select the tab test plan .
-- Select select individual tests and choose the following sequence.
- Body
- Electrical Equipment
- 01 - OBD-capable systems
- 6C - peripheral camera control module | J928
- 6C - peripheral camera control module, functions
- 6C - Calibration, (Repair Group 91)
From here the Vehicle Diagnostic Tester advances the calibration procedure forward.
Make sure light does not reflect off the Peripheral Camera Calibration DeviceVAS6350/6.
Reflections affect the camera and may make it impossible to perform the calibration.