Infrared System, Calibrating: Notes
WARNING: This page does not describe the selected car, but rather 9 other vehicles, including the 2018 Audi S6, 2018 Audi A6 Quattro, 2018 Audi A6, 2017 Audi S6, and 2017 Audi A6 Quattro. However, it is still accessible from the selected car via links, so may be relevant.
Special tools and workshop equipment required
- Setting Device Basic Set - VAS6430/1- or Setting Device Basic Set - VAS6430-
- Night Vision Calibration Tool - VAS6430/6-
- Calibration Tool - Linear Laser - VAS6350/3A- (can be used from the Calibration Tool - VAS6350-)
- Vehicle Diagnostic Tester
- Wheel Alignment Computer
NOTE:
- Make sure the Night Vision System Camera - R212- fits correctly in the bracket and the viewing range for the camera is not blocked.
- Make sure the protective window on the Night Vision System Camera - R212- is not chipped. Replace it if necessary. Refer to Infrared System; Night Vision System Camera, Removing and Installing.
- If the vehicle has an adaptive cruise control and night vision system, then the night vision system must be adjusted/calibrated first and after that can the adaptive cruise control be adjusted. -->
- If the -VAS6430/3- is located on the calibration beam of the -VAS6430/1-, it must be removed.