Rearview Camera -R189-, CALIBRATING
-- Set-up requirements, refer to Calibration Tool VAS6350, INSTALLING AND ALIGNING => Calibration Requirements .
-- Connect the Vehicle Diagnostic Tester.
Calibration Tool - Wheel Center Mountings VAS6350/1 installing:
-- Check which hole circle the rims have.
-- Mount the Calibration Tool - Wheel Center Mountings VAS6350/1 appropriately.
-- To do so, attach three wheel bolt adapters in the bolt circle to each Calibration Tool - Wheel Center Mountings VAS6350/1.
-- Attach paddles to both Calibration Tool - Wheel Center Mountings VAS6350/1 and secure them with clamping screw.
-- Place the Wheel Center Mountings VAS6350/1 onto the wheel bolts on the rear wheels.
The Calibration Tool - Wheel Center Mountings VAS6350/1 are positioned by the "O rings" in the adapters and held in place.
Attach the Calibration Tool - Wheel Center Mountings VAS6350/1 onto the wheels so that any installed "anti-theft" wheel mounting bolts are not connected to the Calibration Tool - Wheel Center Mountings VAS6350/1.
-- Adjust paddle with aid of clamping screws so that they move freely just above the floor. Make sure the paddles move easily.
-- Install the Calibration Unit VAS6350A and align it, refer to Calibration Tool VAS6350, INSTALLING AND ALIGNING .
Distance measurement:
-- Switch on the Calibration Tool - Spacing Laser VAS6350/2.
The display shows how to stop the Calibration Tool - Spacing Laser VAS6350/2. Press the corresponding button.
- Attach with front edge
- Attach with rear edge
-- Hold the Calibration Tool - Spacing Laser VAS6350/2 -2-, as illustrated, flush in the bracket on one side of the calibration board. The Calibration Tool - Spacing Laser VAS6350/2 -2- must sit securely in the bracket.
-- Press the measuring button briefly.
The laser turns on.
-- Make sure that the laser beam from Calibration Tool - Spacing Laser VAS6350/2 -2- hits on the lower, enlarged part of paddle -1-.
If this is not the case, correct the paddles accordingly using clamping screws on the Calibration Tool - Wheel Center Mountings VAS6350/1.
-- Use one hand to secure the Calibration Tool - Spacing Laser VAS6350/2 in the bracket on the Calibration Unit VAS6350A while the laser beam is visible on the paddle.
-- Press the measuring button briefly for the distance measurement.
-- Note the value read off.
-- Repeat measuring procedure in the same manner for the other rear wheel on the other side of the Calibration Unit VAS6350A.
The distance value must be the same on both sides.
If values are not identical:
-- Align the Calibration Unit VAS6350A long enough so that both sides are identical.
Make sure when aligning that the Calibration Tool - Linear Laser VAS6350/3 strikes the center above the Audi rings and the level display remains centered. If necessary, make further corrections.
Dimension measurement -H- :
-- Measure the height of the Calibration Unit VAS6350A, dimension -H- (top edge platform - floor).
Make sure the Calibration Tool - Spacing Laser VAS6350/2 is adjusted correctly (attach with front edge).
The display shows how to stop the Calibration Tool - Spacing Laser VAS6350/2. Press the corresponding button.
- Attach with front edge
- Attach with rear edge
Enter the height and distance dimensions into the Vehicle Diagnostic Tester in "millimeters".
Performing calibration
Vehicle Diagnostic Tester is attached.
-- Select the Diagnostic mode and start the diagnostics.
-- Select the tab test plan .
-- Select select individual tests and choose the following sequence.
- Body
- Electrical Equipment
- 01 - OBD-capable systems
- 6C - rearview camera system/J772
- 6C - rearview camera system control module, functions
- 6C - Calibration, (Repair Group 91)
The Vehicle Diagnostic Tester continues with the calibrating procedure from here on.
Make sure light does not reflect off the calibration platform.
Reflections affect the Rearview Camera -R189- and may make it impossible to perform the calibration.