Home >> Audi >> 2017 >> A3 Sportback e-tron Premium Plus >> Repair and Diagnosis >> Engine Performance >> Engine Control Systems >> Generic Scan Tool [CXUA] (Battery Regulation DTC Table) >> St Generic Scan Tool >> Diagnosis And Testing >> Battery Regulation DTC Table >> Battery Regulation Control Module -J840-, BECM, 2015 - 2017 MY
April 5, 2026: LEMON Manuals is launched! Read the announcement.

Battery Regulation Control Module -J840-, BECM, 2015 - 2017 MY

DTC Error Message Malfunction Criteria and Threshold Value Secondary Parameters with Enable Conditions Monitoring Time Length Frequency of checks, MIL Illumination
P0560 System Voltage
  • Power supply voltage - voltage of DCDC > 4.0 V
  • Battery state HV_ON
  • 0.8 s
  • 2 DCY
P057F Battery Monitor Module Voltage Monitoring Performance
  • SOC > 95 [%] or < 20
  • Battery state HV_ON
  • |Current integral| > 5 [Ah]
  • AND
  • SOC > 95 [%] or < 20
  • Once
  • 2 DCY
P058D Battery Monitor Module Voltage Monitoring Performance
  • Contactor power supply status inconsistency
  • Battery state HV_ON
  • Once
  • 0 DCY
  • Status of alarm line to cell voltages inconsistency
  • Battery state HV_OFF
  • Or
  • PRECHARGE or HV_ON
  • Or
  • EMERGENCY_OFF
  • 1.1 s
  • Self test answer inconsistency
  • Battery state HV_OFF
  • Or
  • EMERGENCY_OFF
  • Once
  • Fixed value stored in NVM = read value
  • Battery state INIT
  • Once
  • Any signal received from BJB = INIT
  • Battery state HV_ON
  • 0.1 s
P0604 Internal Control Module Random Access Memory (RAM) Error
  • RAM test inconsistency
  • Battery state INIT
  • Once
  • 0 DCY
P0606 Control Module Processor
  • A/D conversion time out > 100 μs
  • A/D converter value < 2.5 * 0.9 V
  • A/D converter value > 2.5 * 1.1 V
  • A/D converter value < 4.096 * 0.9 V
  • A/D converter value > 4.096 * 1.1 V
  • All multiplexed values at the internal AD converter are equal
  • Battery state HV_OFF,
  • Or
  • PRECHARGE
  • Or
  • HV_ON
  • Or
  • EMERGENCY_OFF
  • 0.20 s
  • 1 DCY
P062F Internal Control Module EEPROM Error
  • ROM test inconsistency
  • Or
  • NVM test inconsistency
  • Battery state INIT
  • Once
  • 0 DCY
P06B1 Sensor Power Supply "A" Circuit Low
  • Power supply voltage > 30.0 V
  • Or
  • Power supply voltage < 1.0 V
  • Battery state HV_OFF
  • Or
  • PRECHARGE
  • Or
  • HV_ON
  • Or
  • EMERGENCY_OFF
  • 0.3 s
  • 2 DCY
P06B2 Sensor Power Supply "A" Circuit High
  • Power supply voltage > 30.0 V
  • Or
  • Power supply voltage < 1.0 V
  • Battery state HV_OFF
  • Or
  • PRECHARGE
  • Or
  • HV_ON
  • Or
  • EMERGENCY_OFF
  • 0.3 s
  • 2 DCY
P0A1F Battery Energy Control Module "A" Performance
  • Reference voltage = 3.3 V
  • A/D value > 3.63 V
  • Or
  • A/D value < 2.97 V
  • Battery state HV_OFF
  • Or
  • PRECHARGE
  • Or
  • HV_ON
  • Or
  • EMERGENCY_OFF
  • 0.2 s
  • 0 DCY
  • Read data (powertrain CAN controller) = write data
  • Battery state INIT
  • Read data (hybrid CAN controller) = write data
  • Battery state INIT
  • HV_Offtime (ECM) [-]
  • Internal HV_Offtime (BECM) > 8.0 - 240.0 min
  • Or
  • Internal HV_Offtime (BECM) [-]
  • HV_Offtime (ECM) > 8.0 - 240.0 min
  • Battery state HV_ON
  • Once
  • 2 DCY
P0A80 Replace Hybrid/EV Battery Pack
  • Ratio U/I <= 0.308 - 2.766 V/A
  • Battery state: HV_ON
  • Battery temperature > -10° C
  • Battery temperature < 55° C
  • Battery state of charge > 20%
  • Battery state of charge < 80%
  • Battery current gradient 30.0 A/s
  • Battery current zero-crossing
  • battery temperature change <= 2° C
  • Temporarily calculated ratios >= 10
  • 5 times
  • 2 DCY
  • Battery capacity < 11.3 Ah
  • Battery state: HV_ON
  • Battery temperature > 10° C
  • Battery temperature < 50° C
  • And
  • Delta SOC > 25%
  • And
  • DCY duration > 10.0 min
  • And
  • DCY duration < 120.0 min
  • And
  • HV-Off time > 15.0 min
  • Once
P0A95 High Voltage Fuse "A"
  • Battery system voltage [-]
  • Positive contactor voltage < 20.0 V
  • And
  • Positive contactor voltage [-]
  • DC link voltage > 20.0 V
  • And
  • Negative contactor voltage < 20.0 V
  • Battery state HV_ON
  • 0.65 s
  • 0 DCY
  • Snapshot state 1:
  • Positive contactor voltage < 10.0 V
  • And
  • Snapshot state 2:
  • Negative contactor voltage > 25.0 V
  • And
  • Snapshot state 2, 3:
  • Battery system voltage [-]
  • Positive contactor voltage < 10.0 V
  • And
  • Snapshot state 3:
  • Negative contactor voltage < 10.0 V
  • Battery state PRECHARGE (State 6)
  • No sensor error suspicion
  • Positive contactor voltage < 10.0 V
  • State 1 - 3 [-]
  • Contactor voltage [-]
  • DC link voltage
  • Once
P0A9C Hybrid/EV Battery Temperature Sensor "A" Circuit Range/Performance
  • Temperature sensor - average temperature > 20° C
  • Or
  • Average temperature - temperature sensor > 20° C
  • Battery state HV_OFF
  • Or
  • PRECHARGE
  • Or
  • HV_ON
  • Or
  • EMERGENCY_OFF
  • 5.50 s
  • 2 DCY
P0A9D Hybrid/EV Battery Temperature Sensor "A" Circuit Low
  • Temperature sensor A - H > 85° C
  • Battery state HV_OFF
  • Or
  • PRECHARGE
  • Or
  • HV_ON
  • Or
  • EMERGENCY_OFF
  • 5.1 s
  • 2 DCY
  • Temperature sensor A - H < -40° C
P0A9E Hybrid/EV Battery Temperature Sensor "A" Circuit High
  • Temperature sensor A - H > 85° C
  • Battery state HV_OFF
  • Or
  • PRECHARGE
  • Or
  • HV_ON
  • Or
  • EMERGENCY_OFF
  • 5.1 s
  • 2 DCY
  • Temperature sensor A - H < -40° C
P0AA1 Hybrid/EV Battery Positive Contactor Circuit Stuck Closed
  • Battery system voltage [-]
  • Positive contactor voltage < 20.0 V
  • Contactor control closed to open
  • No sensor error suspicion
  • Positive contactor voltage < 10.0 V
  • State 1 - 3 [-]
  • Negative contactor voltage [-]
  • DC link voltage
  • Discharged DC link circuit
  • DC link voltage < battery system voltage * 0.8
  • 0.4 s
  • 1 DCY
  • Snapshot State 1:
  • Battery system voltage [-]
  • Positive contactor voltage < 20.0 V
  • And
  • Snapshot state 2:
  • Battery system voltage [-]
  • Positive contactor voltage < 20.0 V
  • And
  • Battery current < 600.0 mA
  • Battery state PRECHARGE (State 3)
  • No sensor error suspicion
  • Positive contactor voltage < 10.0 V
  • State 1 - 3 [-]
  • Negative contactor voltage [-]
  • DC link voltage
P0AA2 Hybrid/EV Battery Positive Contactor Circuit Stuck Open
  • Battery system voltage [-]
  • Positive contactor voltage > 20.0 V
  • Battery state HV_ON
  • No sensor error suspicion
  • Positive contactor Voltage < 10.0 V
  • State 1 - 3 [-]
  • Contactor voltage [-]
  • DC link voltage
  • Power supply voltage > 8.5 V < 15.5 V
  • 0.80 s
  • 0 DCY
  • Battery system voltage [-]
  • Positive contactor voltage > 30.0 V
  • Battery state PRECHARGE (State 5)
  • No sensor error suspicion
  • Positive contactor voltage < 10.0 V
  • State 1 - 3 [-]
  • Contactor voltage [-]
  • DC link voltage
  • Power supply voltage > 8.5 V < 15.5 V
  • Once
P0AA4 Hybrid/EV Battery Negative Contactor Circuit Stuck Closed
  • Negative contactor voltage < 4.0 V
  • Contactor control closed to open
  • Battery state HV_OFF
  • Or
  • EMERGENCY_OFF
  • Discharged DC link circuit
  • DC link voltage < Battery system voltage * 0, 8
  • 0.4 s
  • 0 DCY
  • Snapshot state 1:
  • Positive contactor voltage [-]
  • DC link voltage < 15.0 V
  • And
  • Snapshot state 2:
  • Positive contactor voltage [-]
  • DC link voltage < 15.0 V
  • And
  • Snapshot state 2:
  • DC link voltage > 30.0 V
  • Battery state PRECHARGE (State 3)
  • No sensor error suspicion |
  • Positive contactor voltage < 10.0 V
  • State 1 - 3 [-]
  • Negative contactor voltage [-]
  • DC link voltage
P0AA5 Hybrid/EV Battery Negative Contactor Circuit Stuck Open
  • Negative contactor voltage > 20.0 V
  • And
  • Positive contactor voltage [-]
  • DC link voltage > 20.0 V
  • Battery state HV_ON
  • No sensor error suspicion
  • Positive contactor voltage < 10.0 V
  • The thresholds
  • State 1 - 3 [-]
  • Contactor voltage [-]
  • DC link voltage
  • Power supply voltage > 8.5 V < 15.5 V
  • 0.8 s
  • 0 DCY
  • DC link voltage < 30.0 V
  • And
  • Negative contactor voltage > 10.0 V
  • Battery state PRECHARGE (State 3)
  • No sensor error suspicion
  • Positive contactor voltage < 10.0 V
  • The thresholds
  • State 1 - 3 [-]
  • Contactor voltage [-]
  • DC link voltage
  • Power supply voltage > 8.5 V < 15.5 V
  • Once
P0AAD Hybrid/EV Battery Pack Air Temperature Sensor "A" Circuit Range/Performance
  • Inlet temperature [-]
  • Average temperature > 10° C
  • Or
  • Average temperature -
  • inlet temperature > 10° C
  • Outlet temperature [-]
  • Average temperature > 10° C
  • Or
  • Average temperature [-]
  • Outlet temperature > 10° C
  • Battery state HV_OFF
  • Or
  • PRECHARGE
  • Or
  • HV_ON
  • EMERGENCY_OFF
  • And
  • Engine off time (battery cool down) > 480.0 min
  • 0.90 s
  • 2 DCY
P0AAE Hybrid/EV Battery Pack Air Temperature Sensor "A" Circuit Low
  • Inlet temperature > 94° C
  • Outlet temperature > 94° C
  • Inlet temperature < -44° C
  • Outlet temperature < -44° C
  • Battery state HV_OFF
  • Or
  • PRECHARGE
  • Or
  • HV_ON
  • EMERGENCY_OFF
  • 0.60 s
  • 2 DCY
P0AAF Hybrid/EV Battery Pack Air Temperature Sensor "A" Circuit High
  • Inlet temperature > 94° C
  • Outlet temperature > 94° C
  • Inlet temperature < -44° C
  • Outlet temperature < -44° C
  • Battery state HV_OFF
  • Or
  • PRECHARGE
  • Or
  • HV_ON
  • EMERGENCY_OFF
  • 0.60 s
  • 2 DCY
P0AB2 Hybrid/EV Battery Pack Air Temperature Sensor "B" Circuit Range/Performance
  • Inlet temperature - average temperature > 10° C
  • Or
  • Average temperature - inlet temperature > 10° C
  • Outlet temperature - average temperature > 10°C
  • Or
  • Average temperature - outlet temperature > 10° C
  • Battery state HV_OFF
  • Or
  • PRECHARGE
  • Or
  • HV_ON
  • EMERGENCY_OFF
  • And
  • Engine off time (battery cool down) > 480.0 min
  • 0.90 s
  • 2 DCY
P0AB3 Hybrid/EV Battery Pack Air Temperature Sensor "B" Circuit Low
  • Inlet temperature > 94° C
  • Outlet temperature > 94° C
  • Inlet temperature < -44° C
  • Outlet temperature < -44° C
  • Battery state HV_OFF
  • Or
  • PRECHARGE
  • Or
  • HV_ON
  • EMERGENCY_OFF
  • 0.60 s
  • 2 DCY
P0AB4 Hybrid/EV Battery Pack Air Temperature Sensor "B" Circuit High
  • Inlet temperature > 94° C
  • Outlet temperature > 94° C
  • Inlet temperature < -44° C
  • Outlet temperature < -44° C
  • Battery state HV_OFF
  • Or
  • PRECHARGE
  • Or
  • HV_ON
  • EMERGENCY_OFF
  • 0.60 s
  • 2 DCY
P0AB9 Hybrid/EV System Performance
  • Battery current < 379.0 A
  • Battery state HV ON
  • 0.2 s
  • 0 DCY
  • Battery current < -9.12
  • Battery state PRECHARGE
  • 0.1 s
P0ABA Hybrid/EV Battery Pack Voltage Sense "A" Circuit
  • Cell controller communication is missing at least one cell controller inconsistency
  • Or
  • ID
  • Or
  • Number of cell inconsistency
  • Or
  • The status of cell controller is abnormal inconsistency
  • Battery state HV_OFF
  • Or
  • PRECHARGE
  • Or
  • HV_ON
  • EMERGENCY_OFF
  • 0.7 s
  • 2.0 counts
  • 0.5 s
  • 1 DCY
P0ABB Hybrid/EV Battery Pack Voltage Sense "A" Circuit Range/Performance
  • Battery system voltage - Typical battery voltage > 10.0 V
  • Or
  • Typical battery voltage - Battery system voltage > 10.0 V
  • Battery state HV_ON
  • Or
  • EMERGENCY_OFF
  • 0.52 s
  • 0 DCY
  • PRECHARGE
  • Or
  • HV_OFF
  • 0.1 s
P0ABC Hybrid/EV Battery Pack Voltage Sense "A" Circuit Low
  • Battery system voltage < 25.0 V
  • PRECHARGE
  • Or
  • HV_OFF
  • 0.17 s
  • 0 DCY
P0ABD Hybrid/EV Battery Pack Voltage Sense "A" Circuit High
  • Battery system voltage > 450.0 V
  • Battery state HV_ON
  • Or
  • EMERGENCY OFF
  • 0.5 s
  • 0 DCY
P0AC0 Hybrid/EV Battery Pack Current Sensor "A" Circuit Range/Performance
  • Air conditioning off:
  • Battery current - (PWR current + DCDC current) > 30.0 A
  • Or
  • Air conditioning on:
  • Battery current - (PWR current + DCDC current) > 60.0 A
  • Gain counter > 3
  • Battery state HV_ON
  • PWR current < 156.0 A
  • And
  • PWR current > 50.0 A
  • 1.0 s
  • 2 DCY
  • PWR current gradient > 5.0 A
  • Battery current gradient > 1.0 A
  • Monitoring time window = 1.0 s
  • And
  • Battery gradient counter < 1
  • And
  • PWR gradient counter > 5
  • Battery state HV_ON
  • Battery current > 0.5 A
  • Battery state HV_OFF
  • 120.0 ms
P0AC1 Hybrid/EV Battery Pack Current Sensor "A" Circuit Low
  • Battery current < -379.0 A
  • Battery state HV_OFF
  • Or
  • PRECHARGE
  • 0.12 s
  • 1 DCY
P0AC2 Hybrid/EV Battery Pack Current Sensor "A" Circuit High
  • Battery current > 267.0 A
  • Battery state HV_ON
  • Or
  • EMERGENCY_OFF
  • 0.55 s
  • 1 DCY
P0AC6 Hybrid/EV Battery Temperature Sensor "B" Circuit Range/Performance
  • Temperature sensor - average temperature > 20° C
  • Or
  • Average temperature - temperature sensor > 20° C
  • Battery state HV_OFF
  • Or
  • PRECHARGE
  • Or
  • HV_ON
  • Or
  • EMERGENCY_OFF
  • 5.50 s
  • 2 DCY
P0AC7 Hybrid/EV Battery Temperature Sensor "B Circuit Low
  • Temperature sensor A - H > 85° C
  • Battery state HV_OFF
  • Or
  • PRECHARGE
  • Or
  • HV_ON
  • Or
  • EMERGENCY_OFF
  • 5.1 s
  • 2 DCY
  • Temperature sensor A - H < -40° C
P0AC8 Hybrid/EV Battery Temperature Sensor "B Circuit High
  • Temperature sensor A - H > 85° C
  • Battery state HV_OFF
  • Or
  • PRECHARGE
  • Or
  • HV_ON
  • Or
  • EMERGENCY_OFF
  • 5.1 s
  • 2 DCY
  • Temperature sensor A - H < -40° C
P0ACB Hybrid/EV Battery Temperature Sensor "C" Circuit Range/Performance
  • Temperature sensor - average temperature > 20° C
  • Or
  • Average temperature - temperature sensor > 20° C
  • Battery state HV_OFF
  • Or
  • PRECHARGE
  • Or
  • HV_ON
  • Or
  • EMERGENCY_OFF
  • 5.50 s
  • 2 DCY
P0ACC Hybrid/EV Battery Temperature Sensor "C" Circuit Low
  • Temperature sensor A - H > 85° C
  • Battery state HV_OFF
  • Or
  • PRECHARGE
  • Or
  • HV_ON
  • Or
  • EMERGENCY_OFF
  • 5.1 s
  • 2 DCY
  • Temperature sensor A - H < -40° C
P0ACD Hybrid/EV Battery Temperature Sensor "C" Circuit High
  • Temperature sensor A - H > 85° C
  • Battery state HV_OFF
  • Or
  • PRECHARGE
  • Or
  • HV_ON
  • Or
  • EMERGENCY_OFF
  • 5.1 s
  • 2 DCY
  • Temperature sensor A - H < -40° C
P0AE2 Hybrid/EV Battery Precharge Contactor Circuit Stuck Closed
  • Snapshot state 1:
  • Battery system voltage [-]
  • Positive contactor voltage < 20.0 V
  • And
  • Snapshot state 2:
  • Battery system voltage [-]
  • Positive contactor voltage < 20.0 V
  • And
  • Battery current >= 600.0 mA
  • Battery state PRECHARGE (State 3)
  • No sensor error suspicion
  • Positive contactor voltage < 10.0 V
  • State 1 - 3 [-]
  • Negative contactor voltage [-]
  • DC link voltage
  • Once
  • 0 DCY
P0AE3 Hybrid/EV Battery Precharge Contactor Circuit Stuck Open
  • Snapshot state 1:
  • Battery system voltage [-]
  • Positive contactor voltage > 30.0 V
  • And
  • Snapshot state 2:
  • Battery system voltage [-]
  • Positive contactor voltage > 30.0 V
  • Battery state PRECHARGE (State 5)
  • No sensor error suspicion
  • Positive contactor voltage < 10.0 V
  • State 1 - 3 [-]
  • Contactor voltage [-]
  • DC link voltage
  • Power supply voltage > 8.5 V < 15.5 V
  • Once
  • 0 DCY
P0AE9 Hybrid/EV Battery Temperature Sensor "D" Circuit Range/Performance
  • Temperature sensor - average temperature > 20° C
  • Or
  • Average temperature - temperature sensor > 20° C
  • Battery state HV_OFF
  • Or
  • PRECHARGE
  • Or
  • HV_ON
  • Or
  • EMERGENCY_OFF
  • 5.50 s
  • 2 DCY
P0AEA Hybrid/EV Battery Temperature Sensor "D" Circuit Low
  • Temperature sensor A - H > 85° C
  • Battery state HV_OFF
  • Or
  • PRECHARGE
  • Or
  • HV_ON
  • Or
  • EMERGENCY_OFF
  • 5.1 s
  • 2 DCY
  • Temperature sensor A - H < -40° C
P0AEB Hybrid/EV Battery Temperature Sensor "D" Circuit High
  • Temperature sensor A - H > 85° C
  • Battery state HV_OFF
  • Or
  • PRECHARGE
  • Or
  • HV_ON
  • Or
  • EMERGENCY_OFF
  • 5.1 s
  • 2 DCY
  • Temperature sensor A - H < -40° C
P0AF8 Hybrid/EV Battery System Voltage
  • Total contactor voltage < 60.0 V
  • And
  • Battery current > 200.0 A
  • Or
  • Battery current > 11.4 A
  • Battery state HV_ON
  • INIT
  • PRECHARGE
  • 5.0 s
  • 0.10 s
  • 1 DCY
P0AFC Hybrid/EV Battery Pack Sensor Module
  • RAM test inconsistency
  • Or
  • Checksum invalid
  • Or
  • Read Data = Write Data
  • Or
  • A/D value inconsistent
  • Battery state HV_ON
  • INIT
  • PRECHARGE
  • 0.4 s
  • 0 DCY
  • Or
  • 1 DCY
P0B15 Hybrid/EV Battery Pack Voltage Sense "B" Circuit Range/Performance
  • Positive contactor voltage [-]
  • Battery system voltage > 10.0 V
  • Contactor voltage [-]
  • DCDC voltage > 10.0 V
  • And
  • Battery system voltage [-]
  • DC link voltage > 10.0 V
  • DCDC voltage [-]
  • Positive contactor voltage > 10.0 V
  • Snapshot from state 1:
  • Positive contactor voltage [-]
  • DC link voltage [-]
  • Negative contactor voltage > 10.0 V
  • Snapshot from state 1:
  • DC link voltage [-]
  • Negative contactor voltage [-]
  • Positive contactor voltage > 10.0 V
  • Battery state PRECHARGE (State 6)
  • Sensor error suspicion
  • Positive contactor voltage > 20.0 V
  • State 1 - 3 [-]
  • DC link voltage [-]
  • Negative contactor voltage
  • Once
  • 0 DCY
P0B16 Hybrid/EV Battery Pack Voltage Sense "B" Circuit Low
  • Positive contactor voltage < 25.0 V
  • Battery state HV_ON
  • 0.5 s
  • 0 DCY
P0B17 Hybrid/EV Battery Pack Voltage Sense "B" Circuit High
  • Positive contactor voltage > 450.0 V
  • Battery state HV_ON
  • Or
  • EMERGENCY_OFF
  • Or
  • PRECHARGE
  • Or
  • HV_OFF
  • 0.5 s
  • 0 DCY
P0B1A Hybrid/EV Battery Pack Voltage Sense "C" Circuit Range/Performance
  • DC link voltage [-]
  • DCDC voltage > 20.0 V
  • And
  • DC link voltage [-]
  • PWR voltage > 20.0 V
  • Battery state HV_ON
  • 0.6 s
  • 0 DCY
  • DCDC voltage [-]
  • DC link voltage > 20.0 V
  • And
  • PWR voltage [-]
  • DC link voltage > 20.0 V
  • PRECHARGE (State 6)
  • No sensor error suspicion
  • Positive contactor voltage > 20.0 V
  • State 1 - 3 [-]
  • DC link voltage [-]
  • Negative contactor voltage
  • Once
P0B1B Hybrid/EV Battery Pack Voltage Sense "C" Circuit Low
  • DC link voltage < 25.0 V
  • Battery state HV_ON
  • 0.5 s
  • 0 DCY
P0B1C Hybrid/EV Battery Pack Voltage Sense "C" Circuit High
  • DC link voltage > 450.0 V
  • Battery state HV_ON
  • Or
  • EMERGENCY_OFF
  • Or
  • PRECHARGE
  • Or
  • HV_OFF
  • 0.5 s
  • 0.57 s
  • 0 DCY
P0B1F Hybrid/EV Battery Pack Voltage Sense "D" Circuit Range/Performance
  • Negative contactor voltage > 10.0 V
  • And
  • Negative contactor voltage [-]
  • Positive contactor voltage + DC link voltage > 30.0 V
  • Negative contactor voltage < -10.0 V
  • And
  • Positive contactor voltage [-]
  • DC link voltage [-]
  • Negative contactor voltage > 30.0 V
  • Battery state HV_ON
  • 0.6 s
  • 0 DCY
  • Snapshot from state 3
  • Or
  • State 6:
  • Negative contactor voltage > 10.0 V
  • Or
  • Snapshot from State 3
  • Or
  • State 6:
  • Negative contactor voltage < -10.0 V
  • Battery state PRECHARGE (State 6)
  • Sensor error suspicion
  • Positive contactor voltage > 20.0 V
  • State 1 - 3 [-]
  • DC link voltage [-]
  • Negative contactor voltage
  • Once
P0B20 Hybrid/EV Battery Pack Voltage Sense "D" Circuit Low
  • Negative contactor voltage < -500.0 V
 
  • 0.5 s
  • 0 DCY
P0B21 Hybrid/EV Battery Pack Voltage Sense "D" Circuit High
  • Negative contactor voltage > 450.0 V
 
  • 0.5 s
  • 0 DCY
P0B34 High Voltage Service Disconnect Circuit Performance
  • Contactor power supply voltage [-]
  • Contactor power supply voltage (BJB) > 8.5 V
  • Battery state HV_ON
  • 0.8 s
  • 2 DCY
P0B3C Hybrid/EV Battery Voltage Sense "A" Circuit Range/Performance
  • Cell voltage 1 - 96 [-]
  • Average cell voltages of each battery stack (12 cells) > 300.0 mV
  • Battery state HV_OFF
  • Or
  • PRECHARGE
  • Or
  • HV_ON
  • Or
  • EMERGENCY_OFF
  • Battery current < 5.0 A
  • 10.0 s
  • 2 DCY
P0B3D Hybrid/EV Battery Voltage Sense "A" Circuit Low
  • Cell voltage < 1.905 V
  • Battery state HV_OFF
  • Or
  • PRECHARGE
  • Or
  • HV_ON
  • Or
  • EMERGENCY_OFF
  • 1.0 s
  • 1 DCY
P0B3E Hybrid/EV Battery Voltage Sense "A" Circuit High
  • Cell voltage > 4.3 V
  • Battery state HV_OFF
  • Or
  • PRECHARGE
  • Or
  • HV_ON
  • Or
  • EMERGENCY_OFF
  • 1.0 s
  • 1 DCY
P0B41 Hybrid/EV Battery Voltage Sense "B" Circuit Range/Performance
  • Cell voltage 1 - 96 [-]
  • Average cell voltages of each battery stack (12 cells) > 300.0 mV
  • Battery state HV_OFF
  • Or
  • PRECHARGE
  • Or
  • HV_ON
  • Or
  • EMERGENCY_OFF
  • Battery current < 5.0 A
  • 10.0 s
  • 2 DCY
P0B42 Hybrid/EV Battery Voltage Sense "B" Circuit Low
  • Cell voltage < 1.905 V
  • Battery state HV_OFF
  • Or
  • PRECHARGE
  • Or
  • HV_ON
  • Or
  • EMERGENCY_OFF
  • 1.0 s
  • 1 DCY
P0B43 Hybrid/EV Battery Voltage Sense "B" Circuit High
  • Cell voltage > 4.3 V
  • Battery state HV_OFF
  • Or
  • PRECHARGE
  • Or
  • HV_ON
  • Or
  • EMERGENCY_OFF
  • 1.0 s
  • 1 DCY
P0B46 Hybrid/EV Battery Voltage Sense "C" Circuit Range/Performance
  • Cell voltage 1 - 96 [-]
  • Average cell voltages of each battery stack (12 cells) > 300.0 mV
  • Battery state HV_OFF
  • Or
  • PRECHARGE
  • Or
  • HV_ON
  • Or
  • EMERGENCY_OFF
  • Battery current < 5.0 A
  • 10.0 s
  • 2 DCY
P0B47 Hybrid/EV Battery Voltage Sense "C" Circuit Low
  • Cell voltage < 1.905 V
  • Battery state HV_OFF
  • Or
  • PRECHARGE
  • Or
  • HV_ON
  • Or
  • EMERGENCY_OFF
  • 1.0 s
  • 1 DCY
P0B48 Hybrid/EV Battery Voltage Sense "C" Circuit High
  • Cell voltage > 4.3 V
  • Battery state HV_OFF
  • Or
  • PRECHARGE
  • Or
  • HV_ON
  • Or
  • EMERGENCY_OFF
  • 1.0 s
  • 1 DCY
P0B4B Hybrid/EV Battery Voltage Sense "D" Circuit Range/Performance
  • Cell voltage 1 - 96 [-]
  • Average cell voltages of each battery stack (12 cells) > 300.0 mV
  • Battery state HV_OFF
  • Or
  • PRECHARGE
  • Or
  • HV_ON
  • Or
  • EMERGENCY_OFF
  • Battery current < 5.0 A
  • 10.0 s
  • 2 DCY
P0B4C Hybrid/EV Battery Voltage Sense "D" Circuit Low
  • Cell voltage < 1.905 V
  • Battery state HV_OFF
  • Or
  • PRECHARGE
  • Or
  • HV_ON
  • Or
  • EMERGENCY_OFF
  • 1.0 s
  • 1 DCY
P0B4D Hybrid/EV Battery Voltage Sense "D" Circuit High
  • Cell voltage > 4.3 V
  • Battery state HV_OFF
  • Or
  • PRECHARGE
  • Or
  • HV_ON
  • Or
  • EMERGENCY_OFF
  • 1.0 s
  • 1 DCY
P0B50 Hybrid/EV Battery Voltage Sense "E" Circuit Range/Performance
  • Cell voltage 1 - 96 [-]
  • Average cell voltages of each battery stack (12 cells) > 300.0 mV
  • Battery state HV_OFF
  • Or
  • PRECHARGE
  • Or
  • HV_ON
  • Or
  • EMERGENCY_OFF
  • Battery current < 5.0 A
  • 10.0 s
  • 2 DCY
P0B51 Hybrid/EV Battery Voltage Sense "E" Circuit Low
  • Cell voltage < 1.905 V
  • Battery state HV_OFF
  • Or
  • PRECHARGE
  • Or
  • HV_ON
  • Or
  • EMERGENCY_OFF
  • 1.0 s
  • 1 DCY
P0B52 Hybrid/EV Battery Voltage Sense "E" Circuit High
  • Cell voltage > 4.3 V
  • Battery state HV_OFF
  • Or
  • PRECHARGE
  • Or
  • HV_ON
  • Or
  • EMERGENCY_OFF
  • 1.0 s
  • 1 DCY
P0B55 Hybrid/EV Battery Voltage Sense "F" Circuit Range/Performance
  • Cell voltage 1 - 96 [-]
  • Average cell voltages of each battery stack (12 cells) > 300.0 mV
  • Battery state HV_OFF
  • Or
  • PRECHARGE
  • Or
  • HV_ON
  • Or
  • EMERGENCY_OFF
  • Battery current < 5.0 A
  • 10.0 s
  • 2 DCY
P0B56 Hybrid/EV Battery Voltage Sense "F" Circuit Low
  • Cell voltage < 1.905 V
  • Battery state HV_OFF
  • Or
  • PRECHARGE
  • Or
  • HV_ON
  • Or
  • EMERGENCY_OFF
  • 1.0 s
  • 1 DCY
P0B57 Hybrid/EV Battery Voltage Sense "F" Circuit High
  • Cell voltage > 4.3 V
  • Battery state HV_OFF
  • Or
  • PRECHARGE
  • Or
  • HV_ON
  • Or
  • EMERGENCY_OFF
  • 1.0 s
  • 1 DCY
P0B5A Hybrid/EV Battery Voltage Sense "G" Circuit Range/Performance
  • Cell voltage 1 - 96 [-]
  • Average cell voltages of each battery stack (12 cells) > 300.0 mV
  • Battery state HV_OFF
  • Or
  • PRECHARGE
  • Or
  • HV_ON
  • Or
  • EMERGENCY_OFF
  • Battery current < 5.0 A
  • 10.0 s
  • 2 DCY
P0B5B Hybrid/EV Battery Voltage Sense "G" Circuit Low
  • Cell voltage < 1.905 V
  • Battery state HV_OFF
  • Or
  • PRECHARGE
  • Or
  • HV_ON
  • Or
  • EMERGENCY_OFF
  • 1.0 s
  • 1 DCY
P0B5C Hybrid/EV Battery Voltage Sense "G" Circuit High
  • Cell voltage > 4.3 V
  • Battery state HV_OFF
  • Or
  • PRECHARGE
  • Or
  • HV_ON
  • Or
  • EMERGENCY_OFF
  • 1.0 s
  • 1 DCY
P0B5F Hybrid/EV Battery Voltage Sense "H" Circuit Range/Performance
  • Cell voltage 1 - 96 [-]
  • Average cell voltages of each battery stack (12 cells) > 300.0 mV
  • Battery state HV_OFF
  • Or
  • PRECHARGE
  • Or
  • HV_ON
  • Or
  • EMERGENCY_OFF
  • Battery current < 5.0 A
  • 10.0 s
  • 2 DCY
P0B60 Hybrid/EV Battery Voltage Sense "H" Circuit Low
  • Cell voltage < 1.905 V
  • Battery state HV_OFF
  • Or
  • PRECHARGE
  • Or
  • HV_ON
  • Or
  • EMERGENCY_OFF
  • 1.0 s
  • 1 DCY
P0B61 Hybrid/EV Battery Voltage Sense "H" Circuit High
  • Cell voltage > 4.3 V
  • Battery state HV_OFF
  • Or
  • PRECHARGE
  • Or
  • HV_ON
  • Or
  • EMERGENCY_OFF
  • 1.0 s
  • 1 DCY
P0BBE Hybrid/EV Battery Pack Voltage Variation
  • Alarm line input = alarm line output
  • Battery state INIT
  • Cell status no cell under or over voltage
  • Once
  • 0 DCY
  • Alarm line input to status of cell voltages inconsistency
  • Battery state HV_OFF
  • Or
  • PRECHARGE
  • Or
  • HV_ON
  • Or
  • EMERGENCY_OFF
  • 1.0 s
P0BC3 Hybrid/EV Battery Temperature Sensor "E" Circuit Range/Performance
  • Temperature sensor - average temperature > 20° C
  • Or
  • Average temperature - temperature sensor > 20° C
  • Battery state HV_OFF
  • Or
  • PRECHARGE
  • Or
  • HV_ON
  • Or
  • EMERGENCY_OFF
  • 5.5 s
  • 2 DCY
P0BC4 Hybrid/EV Battery Temperature Sensor "E" Circuit Low
  • Temperature sensor A - H > 85° C
  • Battery state HV_OFF
  • Or
  • PRECHARGE
  • Or
  • HV_ON
  • Or
  • EMERGENCY_OFF
  • 5.1 s
  • 2 DCY
  • Temperature sensor A - H < -40° C
P0BC5 Hybrid/EV Battery Temperature Sensor "E" Circuit High
  • Temperature sensor A - H > 85° C
  • Battery state HV_OFF
  • Or
  • PRECHARGE
  • Or
  • HV_ON
  • Or
  • EMERGENCY_OFF
  • 5.1 s
  • 2 DCY
  • Temperature sensor A - H < -40° C
P0BC8 Hybrid/EV Battery Pack Cooling Fan 1 Sense Range/Performance
  • Fan feedback voltage > 1.37 - 3.43 V
  • Or
  • Fan feedback voltage < 0.0 - 1.04 V
  • Battery state HV_OFF
  • Or
  • PRECHARGE
  • Or
  • HV_ON
  • Or
  • EMERGENCY_OFF
  • And
  • Fan duty cycle >= 20%
  • 30.0 s
  • 2 DCY
P0BC9 Hybrid/EV Battery Pack Cooling Fan 1 Sense Circuit Low
  • Fan feedback voltage < 0.1 V
  • Battery state HV_OFF
  • Or
  • PRECHARGE
  • Or
  • HV_ON
  • Or
  • EMERGENCY_OFF
  • And
  • Fan duty cycle >= 20%
  • 10.0 s
  • 2 DCY
P0BCA Hybrid/EV Battery Pack Cooling Fan 1 Sense Circuit High
  • Fan feedback voltage > 3.45 V
  • Battery state HV_OFF
  • Or
  • PRECHARGE
  • Or
  • HV_ON
  • Or
  • EMERGENCY_OFF
  • And
  • Fan duty cycle >= 20%
  • 10.0 s
  • 2 DCY
P0C34 Hybrid/EV Battery Temperature Sensor "F" Circuit Range/Performance
  • Temperature sensor - average temperature > 20° C
  • Or
  • Average temperature - temperature sensor > 20° C
  • Battery state HV_OFF
  • Or
  • PRECHARGE
  • Or
  • HV_ON
  • Or
  • EMERGENCY_OFF
  • 5.5 s
  • 2 DCY
P0C35 Hybrid/EV Battery Temperature Sensor "F" Circuit Low
  • Temperature sensor A - H > 85° C
  • Battery state HV_OFF
  • Or
  • PRECHARGE
  • Or
  • HV_ON
  • Or
  • EMERGENCY_OFF
  • 5.1 s
  • 2 DCY
  • Temperature sensor A - H < -40° C
P0C36 Hybrid/EV Battery Temperature Sensor "F" Circuit High
  • Temperature sensor A - H > 85° C
  • Battery state HV_OFF
  • Or
  • PRECHARGE
  • Or
  • HV_ON
  • Or
  • EMERGENCY_OFF
  • 5.1 s
  • 2 DCY
  • Temperature sensor A - H < -40° C
P0C43 Hybrid/EV Battery Pack Coolant Temperature Sensor "A" Circuit Range/Performance
  • Inlet temperature - outlet temperature > 30° C
  • Battery state HV_ON
  • 120.0 s after battery system wake up
  • Coolant pump controlled on
  • 10.0 s
  • Once
  • 2 DCY
P0C44 Hybrid/EV Battery Pack Coolant Temperature Sensor "A" Circuit Low
  • Inlet temperature > 94° C
  • Or
  • Inlet temperature < -44° C
  • Outlet temperature > 94° C
  • Or
  • Outlet temperature < -44° C
  • Battery state HV_OFF
  • Or
  • PRECHARGE
  • Or
  • HV_ON
  • Or
  • EMERGENCY_OFF
  • 3.0 s
  • 2 DCY
P0C45 Hybrid/EV Battery Pack Coolant Temperature Sensor "A" Circuit High
  • Inlet temperature > 94° C
  • Or
  • Inlet temperature < -44° C
  • Outlet temperature > 94° C
  • Or
  • Outlet temperature < -44° C
  • Battery state HV_OFF
  • Or
  • PRECHARGE
  • Or
  • HV_ON
  • Or
  • EMERGENCY_OFF
  • 3.0 s
  • 2 DCY
P0C48 Hybrid/EV Battery Pack Coolant Pump "A" Control Circuit Low
  • Pump feedback signal low > 10.0 s
  • Battery state HV_ON
  • Power supply voltage > 8.5 V < 15.5 V
  • 10.0 s
  • 2 DCY
P0C49 Hybrid/EV Battery Pack Coolant Pump "A" Control Circuit High
  • Pump feedback signal high > 10.0 s
  • Battery state HV_ON
  • Power supply voltage > 8.5 V < 15.5 V
  • 10.0 s
  • 2 DCY
P0C4A Hybrid/EV Battery Pack Coolant Pump "A" Control Performance
  • Pump feedback signal for dry run or broken blades
  • Battery state HV_ON
  • Power supply voltage > 8.5 V < 15.5 V
  • 10.0 s
  • 2 DCY
P0C78 Hybrid/EV Battery System Precharge Time Too Long
  • Battery system voltage - positive contactor voltage > 20.0 V
  • Battery state PRECHARGE
  • 0.7 s
  • 0 DCY
P0C7D Hybrid/EV Battery Temperature Sensor "G" Circuit Range/Performance
  • Temperature sensor - average temperature > 20° C
  • Or
  • Average temperature - temperature sensor > 20° C
  • Battery state HV_OFF
  • Or
  • PRECHARGE
  • Or
  • HV_ON
  • Or
  • EMERGENCY_OFF
  • 5.5 s
  • 2 DCY
P0C7E Hybrid/EV Battery Temperature Sensor "G" Circuit Low
  • Temperature sensor A - H > 85° C
  • Battery state HV_OFF
  • Or
  • PRECHARGE
  • Or
  • HV_ON
  • Or
  • EMERGENCY_OFF
  • 5.1 s
  • 2 DCY
  • Temperature sensor A - H < -40° C
P0C7F Hybrid/EV Battery Temperature Sensor "G" Circuit High
  • Temperature sensor A - H > 85° C
  • Battery state HV_OFF
  • Or
  • PRECHARGE
  • Or
  • HV_ON
  • Or
  • EMERGENCY_OFF
  • 5.1 s
  • 2 DCY
  • Temperature sensor A - H < -40° C
P0C82 Hybrid/EV Battery Temperature Sensor "H" Circuit Range/Performance
  • Temperature sensor - average temperature > 20° C
  • Or
  • Average temperature - temperature sensor > 20° C
  • Battery state HV_OFF
  • Or
  • PRECHARGE
  • Or
  • HV_ON
  • Or
  • EMERGENCY_OFF
  • 5.5 s
  • 2 DCY
P0C83 Hybrid/EV Battery Temperature Sensor "H" Circuit Low
  • Temperature sensor A - H > 85° C
  • Battery state HV_OFF
  • Or
  • PRECHARGE
  • Or
  • HV_ON
  • Or
  • EMERGENCY_OFF
  • 5.1 s
  • 2 DCY
  • Temperature sensor A - H < -40° C
P0C84 Hybrid/EV Battery Temperature Sensor "H" Circuit High
  • Temperature sensor A - H > 85° C
  • Battery state HV_OFF
  • Or
  • PRECHARGE
  • Or
  • HV_ON
  • Or
  • EMERGENCY_OFF
  • 5.1 s
  • 2 DCY
  • Temperature sensor A - H < -40° C
P0CA6 Hybrid/EV Battery Charging Current High
  • Battery current > 250.0 A
  • Or
  • Battery current < -345.0 A
  • Battery state PRECHARGE
  • Or
  • HV_ON
  • Or
  • EMERGENCY_OFF
  • 10.0 s
  • 2 DCY
P0CA7 Hybrid/EV Battery Discharging Current High
  • Battery current > 250.0 A
  • Or
  • Battery current < -345.0 A
  • Battery state PRECHARGE
  • Or
  • HV_ON
  • Or
  • EMERGENCY_OFF
  • 10.0 s
  • 2 DCY
P0CD7 Hybrid/EV Battery Pack Coolant Temperature Sensor "B" Circuit Low
  • Inlet temperature > 94° C
  • Or
  • Inlet temperature < -44° C
  • Outlet temperature > 94° C
  • Or
  • Outlet temperature < -44° C
  • Battery state HV_OFF
  • Or
  • PRECHARGE
  • Or
  • HV_ON
  • Or
  • EMERGENCY_OFF
  • 3.0 s
  • 2 DCY
P0CD8 Hybrid/EV Battery Pack Coolant Temperature Sensor "B" Circuit High
  • Inlet temperature > 94° C
  • Or
  • Inlet temperature < -44° C
  • Outlet temperature > 94° C
  • Or
  • Outlet temperature < -44° C
  • Battery state HV_OFF
  • Or
  • PRECHARGE
  • Or
  • HV_ON
  • Or
  • EMERGENCY_OFF
  • 3.0 s
  • 2 DCY
P0CE1 Hybrid/EV Battery Pack Coolant Control Valve "A" Stuck On
  • Fail and pass counter condition:
  • Difference of Inlet and low temperature circuit sensor at monitoring start - difference of Inlet and low temperature circuit sensor at actual time stamp < 1° C
  • (Count fail - count pass) / (count fail + count pass) >= 1/3
  • Battery state HV_ON
  • Vehicle speed >= 20 km/h
  • Bypass valve controlled to cooler in low temperature circuit
  • Average difference of inlet > 5° C
  • And
  • Low temperature circuit sensor at start
  • Valve control close to open
  • Maximum monitoring time length 600.0 s
  • Count fail + count pass > 240 counts
  • Power supply voltage > 8.5 V < 15.5 V
  • Once
  • 600.0 s
  • 2 DCY
P0CE2 Hybrid/EV Battery Pack Coolant Control Valve "A" Control Circuit Low
  • Valve circuit voltage < 1.33 V
  • Battery state HV_OFF
  • Or
  • PRECHARGE
  • Or
  • HV_ON
  • Or
  • EMERGENCY_OFF
  • Valve control open
  • Power supply voltage > 8.5 V < 15.5 V
  • 1.5 s
  • 2 DCY
P0CE3 Hybrid/EV Battery Pack Coolant Control Valve "A" Control Circuit High
  • Valve circuit voltage > 1.33 V
  • Battery state HV_OFF
  • Or
  • PRECHARGE
  • Or
  • HV_ON
  • Or
  • EMERGENCY_OFF
  • Valve control close
  • Power supply voltage > 8.5 V < 15.5 V
  • 1.5 s
  • 2 DCY
P0CFF Hybrid/EV Battery Pack Coolant Pump Stuck
  • Pump feedback signal for stuck
  • Battery state HV_ON
  • Power supply voltage > 8.5 V < 15.5 V
  • 10.0 s
  • 2DCY
P0DAC Hybrid/EV Battery Cell Balancing Circuit "A"
  • Checksum is invalid inconsistency
  • Internal circuit test pattern inconsistency
  • RAM test inconsistency
  • ROM test inconsistency
  • Read data = write data
  • A/D value inconsistent
  • Battery state INIT
  • HV_OFF
  • Or
  • PRECHARG
  • Or
  • HV_ON
  • 0.4 s
  • 1.0 s
  • 1 DCY
  • Or
  • 2 DCY
  • Or
  • 0 DCY
P0DAF Hybrid/EV Battery Cell Balancing Circuit "A" Range/Performance
  • Cell voltage by measurement IC [cell no] - cell voltage by monitoring IC [cell no] > 0.2 V
  • Cell no: cell no 1 - 96
  • Battery state HV_ON
  • Or
  • EMERGENCY_OFF
  • Or
  • PRECHARGE HV_OFF
  • 0.48 s
  • 2 DCY
P0DB0 Hybrid/EV Battery Cell Balancing Circuit "B"
  • Checksum is invalid inconsistency
  • Internal circuit test pattern inconsistency
  • RAM test inconsistency
  • ROM test inconsistency
  • Read data = write data
  • A/D value inconsistent
  • Battery state INIT
  • HV_OFF
  • Or
  • PRECHARGE
  • Or
  • HV_ON
  • 0.4 s
  • 1.0 s
  • 1 DCY
  • Or
  • 2 DCY
  • Or
  • 0 DCY
P0DB3 Hybrid/EV Battery Cell Balancing Circuit "B" Range/Performance
  • Cell voltage by measurement IC [cell no] - cell voltage by monitoring IC [cell no] > 0.2 V
  • Cell no: cell no 1 - 96
  • Battery state HV_ON
  • Or
  • EMERGENCY_OFF
  • Or
  • PRECHARGE HV_OFF
  • 0.48 s
  • 2 DCY
P0DB4 Hybrid/EV Battery Cell Balancing Circuit "C"
  • Checksum is invalid inconsistency
  • Internal circuit test pattern inconsistency
  • RAM test inconsistency
  • ROM test inconsistency
  • Read data = write data
  • A/D value inconsistent
  • Battery state INIT
  • HV_OFF
  • Or
  • PRECHARGE
  • Or
  • HV_ON
  • 0.4 s
  • 1.0 s
  • 1 DCY
  • Or
  • 2 DCY
  • Or
  • 0 DCY
  • Cell voltage cell no > 4.9 V
  • Or
  • Cell voltage cell no < 1.0 V
  • Cell no: cell number 1 - 96
  • Battery state HV_OFF
  • Or
  • PRECHARGE
  • Or
  • HV_ON
  • Or
  • EMERGENCY_OFF
  • 0.48 s
  • 1 DCY
  • Or
  • 2 DCY
P0DB7 Hybrid/EV Battery Cell Balancing Circuit "C" Range/Performance
  • Cell voltage by measurement IC [cell no] - cell voltage by monitoring IC [cell no] > 0.2 V
  • Cell no: cell no 1 - 96
  • Battery state HV_ON
  • Or
  • EMERGENCY_OFF
  • Or
  • PRECHARGE HV_OFF
  • 0.48 s
  • 2 DCY
P0DB8 Hybrid/EV Battery Cell Balancing Circuit "D"
  • Checksum is invalid inconsistency
  • Internal circuit test pattern inconsistency
  • RAM test inconsistency
  • ROM test inconsistency
  • Read data = write data
  • A/D value inconsistent
  • Battery state INIT
  • HV_OFF
  • Or
  • PRECHARGE
  • Or
  • HV_ON
  • 0.4 s
  • 1.0 s
  • 1 DCY
  • Or
  • 2 DCY
  • Or
  • 0 DCY
P0DBB Hybrid/EV Battery Cell Balancing Circuit "D" Range/Performance
  • Cell voltage by measurement IC [cell no] - cell voltage by monitoring IC [cell no] > 0.2 V
  • Cell no: cell no 1 - 96
  • Battery state HV_ON
  • Or
  • EMERGENCY_OFF
  • Or
  • PRECHARGE HV_OFF
  • 0.48 s
  • 2 DCY
P0DBC Hybrid/EV Battery Cell Balancing Circuit "E"
  • Checksum is invalid inconsistency
  • Internal circuit test pattern inconsistency
  • RAM test inconsistency
  • ROM test inconsistency
  • Read data = write data
  • A/D value inconsistent
  • Battery state INIT
  • HV_OFF
  • Or
  • PRECHARGE
  • Or
  • HV_ON
  • 0.4 s
  • 1.0 s
  • 1 DCY
  • Or
  • 2 DCY
  • Or
  • 0 DCY
P0DBF Hybrid/EV Battery Cell Balancing Circuit "E" Range/Performance
  • Cell voltage by measurement IC [cell no] - cell voltage by monitoring IC [cell no] > 0.2 V
  • Cell no: cell no 1 - 96
  • Battery state HV_ON
  • Or
  • EMERGENCY_OFF
  • Or
  • PRECHARGE HV_OFF
  • 0.48 s
  • 2 DCY
P0DC0 Hybrid/EV Battery Cell Balancing Circuit "F"
  • Checksum is invalid inconsistency
  • Internal circuit test pattern inconsistency
  • RAM test inconsistency
  • ROM test inconsistency
  • Read data = write data
  • A/D value inconsistent
  • Battery state INIT
  • HV_OFF
  • Or
  • PRECHARGE
  • Or
  • HV_ON
  • 0.4 s
  • 1.0 s
  • 1 DCY
  • Or
  • 2 DCY
  • Or
  • 0 DCY
P0DC3 Hybrid/EV Battery Cell Balancing Circuit "F" Range/Performance
  • Cell voltage by measurement IC [cell no] - cell voltage by monitoring IC [cell no] > 0.2 V
  • Cell no: cell no 1 - 96
  • Battery state HV_ON
  • Or
  • EMERGENCY_OFF
  • Or
  • PRECHARGE HV_OFF
  • 0.48 s
  • 2 DCY
P0DC4 Hybrid/EV Battery Cell Balancing Circuit "G"
  • Checksum is invalid inconsistency
  • internal circuit test pattern inconsistency
  • RAM test inconsistency
  • ROM test inconsistency
  • Read data = write data
  • A/D value inconsistent
  • Battery state INIT
  • HV_OFF
  • Or
  • PRECHARGE
  • Or
  • HV_ON
  • 0.4 s
  • 1.0 s
  • 1 DCY
  • Or
  • 2 DCY
  • Or
  • 0 DCY
P0DC7 Hybrid/EV Battery Cell Balancing Circuit "G" Range/Performance
  • Cell voltage by measurement IC [cell no] - cell voltage by monitoring IC [cell no] > 0.2 V
  • Cell no: cell no 1 - 96
  • Battery state HV_ON
  • Or
  • EMERGENCY_OFF
  • Or
  • PRECHARGE HV_OFF
  • 0.48 s
  • 2 DCY
P0DC8 Hybrid/EV Battery Cell Balancing Circuit "H"
  • Checksum is invalid inconsistency
  • internal circuit test pattern inconsistency
  • RAM test inconsistency
  • ROM test inconsistency
  • Read data = write data
  • A/D value inconsistent
  • Battery state INIT
  • HV_OFF
  • Or
  • PRECHARGE
  • Or
  • HV_ON
  • 0.4 s
  • 1.0 s
  • 1 DCY
  • Or
  • 2 DCY
  • Or
  • 0 DCY
P0DCB Hybrid/EV Battery Cell Balancing Circuit "H" Range/Performance
  • Cell voltage by measurement IC [cell no] - cell voltage by monitoring IC [cell no] > 0.2 V
  • Cell no: cell no 1 - 96
  • Battery state HV_ON
  • Or
  • EMERGENCY_OFF
  • Or
  • PRECHARGE HV_OFF
  • 0.48 s
  • 2 DCY
P0E2D Internal Control Module Hybrid/EV Battery Monitor Performance
  • High side driver input in BJB = high
  • Battery state INIT
  • High side driver output = low
 
  • 0 DCY
  • High side driver input in BJB = low
  • Battery state INIT
  • High side driver output = high
 
  • 2 DCY
P1296 Malfunction In Cooling System
  • Low temperature circuit sensor [-]
  • Battery Inlet temperature sensor <= 5° C
  • Battery state HV_ON
  • Active battery cooling time 600.0 s
  • Low temperature circuit > 40° C
  • Power supply voltage > 8.5 V < 15.5 V
  • Once
  • 600.0 s
  • 2 DCY
U0001 High Speed CAN Communication Bus
  • CAN controller bus off flag bus off
  • Battery state HV_OFF
  • Or
  • PRECHARGE
  • Or
  • HV_ON
  • Or
  • EMERGENCY_OFF
  • CAN active
  • Once
  • 0 DCY
U0002 High Speed CAN Communication Bus Performance
  • Any message not received
  • CAN active
  • 0.45 s
  • 0 DCY
  • Or
  • 2 DCY
U0028 Vehicle Communication Bus A
  • CAN controller bus off flag bus off
  • Battery state HV_OFF
  • Or
  • PRECHARGE
  • Or
  • HV_ON
  • Or
  • EMERGENCY_OFF
  • CAN active
  • Once
  • 0 DCY
U0029 Vehicle Communication Bus A Performance
  • Any message not received
  • CAN active
  • 0.45 s
  • 0 DCY
  • Or
  • 2 DCY
U0037 Vehicle Communication Bus B
  • CAN controller bus off flag bus off
  • Battery state HV_OFF
  • Or
  • PRECHARGE
  • Or
  • HV_ON
  • Or
  • EMERGENCY_OFF
  • CAN active
  • Once
  • 0 DCY
U0038 Vehicle Communication Bus B Performance
  • Any message not received
  • CAN active
  • 0.45 s
  • 0 DCY
  • Or
  • 2 DCY
U0100 Lost Communication With ECM/PCM "A"
  • Message of CAN not received
  • Battery state HV_OFF
  • Or
  • PRECHARGE
  • Or
  • HV_ON
  • Or
  • EMERGENCY_OFF
  • CAN active
  • 0.5 s
  • Or
  • 1.0 s
  • Or
  • 5.0 s
  • 2 DCY
  • Or
  • 0 DCY
U0110 Lost Communication With Drive Motor Control Module "A"
  • Message of CAN not received
  • Battery state HV_OFF
  • Or
  • PRECHARGE
  • Or
  • HV_ON
  • Or
  • EMERGENCY_OFF
  • CAN active
  • 0.5 s
  • Or
  • 1.0 s
  • Or
  • 5.0 s
  • 2 DCY
  • Or
  • 0 DCY
U0121 Lost Communication With Anti-Lock Brake System (ABS) Control Module
  • Message of CAN not received
  • Battery state HV_OFF
  • Or
  • PRECHARGE
  • Or
  • HV_ON
  • Or
  • EMERGENCY_OFF
  • 0.5 s
  • Or
  • 1.0 s
  • Or
  • 5.0 s
  • 0.80 s
  • 0.50 s
  • 5.0 s
  • 2 DCY
U0122 Lost Communication With Vehicle Dynamics Control Module
  • Message of CAN not received
  • Battery state HV_OFF
  • Or
  • PRECHARGE
  • Or
  • HV_ON
  • Or
  • EMERGENCY_OFF
  • CAN active
  • 0.5 s
  • Or
  • 1.0 s
  • Or
  • 5.0 s
  • 2 DCY
  • Or
  • 0 DCY
U0146 Lost Communication With Gateway "A"
  • Message of CAN not received
  • Battery state HV_OFF
  • Or
  • PRECHARGE
  • Or
  • HV_ON
  • Or
  • EMERGENCY_OFF
  • 0.5 s
  • Or
  • 1.0 s
  • Or
  • 5.0 s
  • 0.80 s
  • 0.50 s
  • 5.0 s
  • 2 DCY
U0164 Lost Communication With HVAC Control Module
  • Message of CAN not received
  • Battery state HV_OFF
  • Or
  • PRECHARGE
  • Or
  • HV_ON
  • Or
  • EMERGENCY_OFF
  • CAN active
  • 0.5 s
  • Or
  • 1.0 s
  • Or
  • 5.0 s
  • 2 DCY
  • Or
  • 0 DCY
U019B Lost Communication With Battery Charger Control Module
  • Message of CAN not received
  • Battery state HV_OFF
  • Or
  • PRECHARGE
  • Or
  • HV_ON
  • Or
  • EMERGENCY_OFF
  • CAN active
  • 0.5 s
  • Or
  • 1.0 s
  • Or
  • 5.0 s
  • 2 DCY
  • Or
  • 0 DCY
U01A0 Lost Communication with Hybrid/EV Battery Interface Control Module "A"
  • Message of CAN not received
  • Battery state HV_OFF
  • Or
  • PRECHARGE
  • Or
  • HV_ON
  • Or
  • EMERGENCY_OFF
  • CAN active
  • 0.5 s
  • Or
  • 1.0 s
  • Or
  • 5.0 s
  • 2 DCY
  • Or
  • 0 DCY
U01A1 Lost Communication with Hybrid/EV Battery Interface Control Module "B"
  • Message of CAN not received
  • Battery state HV_OFF
  • Or
  • PRECHARGE
  • Or
  • HV_ON
  • Or
  • EMERGENCY_OFF
  • CAN active
  • 0.5 s
  • Or
  • 1.0 s
  • Or
  • 5.0 s
  • 2 DCY
  • Or
  • 0 DCY
U01A2 Lost Communication with Hybrid/EV Battery Interface Control Module "C"
  • Message of CAN not received
  • Battery state HV_OFF
  • Or
  • PRECHARGE
  • Or
  • HV_ON
  • Or
  • EMERGENCY_OFF
  • CAN active
  • 0.5 s
  • Or
  • 1.0 s
  • Or
  • 5.0 s
  • 2 DCY
  • Or
  • 0 DCY
U01A3 Lost Communication with Hybrid/EV Battery Interface Control Module "D"
  • Message of CAN not received
  • Battery state HV_OFF
  • Or
  • PRECHARGE
  • Or
  • HV_ON
  • Or
  • EMERGENCY_OFF
  • CAN active
  • 0.5 s
  • Or
  • 1.0 s
  • Or
  • 5.0 s
  • 2 DCY
  • Or
  • 0 DCY
U01A4 Lost Communication with Hybrid/EV Battery Interface Control Module "E"
  • Message of CAN not received
  • Battery state HV_OFF
  • Or
  • PRECHARGE
  • Or
  • HV_ON
  • Or
  • EMERGENCY_OFF
  • CAN active
  • 0.5 s
  • Or
  • 1.0 s
  • Or
  • 5.0 s
  • 2 DCY
  • Or
  • 0 DCY
U01A5 Lost Communication with Hybrid/EV Battery Interface Control Module "F"
  • Message of CAN not received
  • Battery state HV_OFF
  • Or
  • PRECHARGE
  • Or
  • HV_ON
  • Or
  • EMERGENCY_OFF
  • CAN active
  • 0.5 s
  • Or
  • 1.0 s
  • Or
  • 5.0 s
  • 2 DCY
  • Or
  • 0 DCY
U01A6 Lost Communication with Hybrid/EV Battery Interface Control Module "G"
  • Message of CAN not received
  • Battery state HV_OFF
  • Or
  • PRECHARGE
  • Or
  • HV_ON
  • Or
  • EMERGENCY_OFF
  • CAN active
  • 0.5 s
  • Or
  • 1.0 s
  • Or
  • 5.0 s
  • 2 DCY
  • Or
  • 0 DCY
U01A7 Lost Communication with Hybrid/EV Battery Interface Control Module "H"
  • Message of CAN not received
  • Battery state HV_OFF
  • Or
  • PRECHARGE
  • Or
  • HV_ON
  • Or
  • EMERGENCY_OFF
  • CAN active
  • 0.5 s
  • Or
  • 1.0 s
  • Or
  • 5.0 s
  • 2 DCY
  • Or
  • 0 DCY
U029A Lost Communication With Hybrid/EV Battery Pack Sensor Module
  • Message of CAN not received
  • Battery state HV_OFF
  • Or
  • PRECHARGE
  • Or
  • HV_ON
  • Or
  • EMERGENCY_OFF
  • CAN active
  • 0.5 s
  • Or
  • 1.0 s
  • Or
  • 5.0 s
  • 2 DCY
  • Or
  • 0 DCY
U02A0 Invalid Data Received From Hybrid/EV Battery Interface Control Module "D"
  • DLC of received message shorter than specification
  • Or
  • Consecutive messages with same message counter >= 5
  • Or
  • Checksum invalid
  • Battery state HV_OFF
  • Or
  • PRECHARGE
  • Or
  • HV_ON
  • Or
  • EMERGENCY_OFF
  • CAN active
  • 1 time
  • Or
  • Message cycle
  • Or
  • 1 times
  • 2 DCY
  • Or
  • 1 DCY
  • Or
  • 0 DCY
U0335 Software Incompatibility With Hybrid/EV Battery Pack Sensor Module
  • No matching entries inconsistency
  • Battery state HV_OFF
  • Or
  • PRECHARGE
  • Or
  • HV_ON
  • Or
  • EMERGENCY_OFF
  • 2 times
  • 2 DCY
U0337 Software Incompatibility with Battery Charger Control Module
  • No matching entries inconsistency
  • Battery state HV_OFF
  • Or
  • PRECHARGE
  • Or
  • HV_ON
  • Or
  • EMERGENCY_OFF
  • 2 times
  • 2 DCY
U033A Software Incompatibility With Hybrid/EV Battery Interface Control Module "A"
  • No matching entries inconsistency
  • Battery state HV_OFF
  • Or
  • PRECHARGE
  • Or
  • HV_ON
  • Or
  • EMERGENCY_OFF
  • 2 times
  • 2 DCY
U033B Software Incompatibility With Hybrid/EV Battery Interface Control Module "B"
  • No matching entries inconsistency
  • Battery state HV_OFF
  • Or
  • PRECHARGE
  • Or
  • HV_ON
  • Or
  • EMERGENCY_OFF
  • 2 times
  • 2 DCY
U033C Software Incompatibility With Hybrid/EV Battery Interface Control Module "C"
  • No matching entries inconsistency
  • Battery state HV_OFF
  • Or
  • PRECHARGE
  • Or
  • HV_ON
  • Or
  • EMERGENCY_OFF
  • 2 times
  • 2 DCY
U033D Software Incompatibility With Hybrid/EV Battery Interface Control Module "D"
  • No matching entries inconsistency
  • Battery state HV_OFF
  • Or
  • PRECHARGE
  • Or
  • HV_ON
  • Or
  • EMERGENCY_OFF
  • 2 times
  • 2 DCY
U033E Software Incompatibility With Hybrid/EV Battery Interface Control Module "E"
  • No matching entries inconsistency
  • Battery state HV_OFF
  • Or
  • PRECHARGE
  • Or
  • HV_ON
  • Or
  • EMERGENCY_OFF
  • 2 times
  • 2 DCY
U033F Software Incompatibility With Hybrid/EV Battery Interface Control Module "F"
  • No matching entries inconsistency
  • Battery state HV_OFF
  • Or
  • PRECHARGE
  • Or
  • HV_ON
  • Or
  • EMERGENCY_OFF
  • 2 times
  • 2 DCY
U0340 Software Incompatibility With Hybrid/EV Battery Interface Control Module "G"
  • No matching entries inconsistency
  • Battery state HV_OFF
  • Or
  • PRECHARGE
  • Or
  • HV_ON
  • Or
  • EMERGENCY_OFF
  • 2 times
  • 2 DCY
U0341 Software Incompatibility With Hybrid/EV Battery Interface Control Module "H"
  • No matching entries inconsistency
  • Battery state HV_OFF
  • Or
  • PRECHARGE
  • Or
  • HV_ON
  • Or
  • EMERGENCY_OFF
  • 2 times
  • 2 DCY
U0401 Invalid Data Received From ECM/PCM "A"
  • DLC of received message shorter than specification
  • Or
  • Consecutive messages with same message counter >= 5
  • Or
  • Checksum invalid
  • Battery state HV_OFF
  • Or
  • PRECHARGE
  • Or
  • HV_ON
  • Or
  • EMERGENCY_OFF
  • CAN active
  • 1 time
  • Or
  • Message cycle
  • Or
  • 1 times
  • 2 DCY
  • Or
  • 1 DCY
  • Or
  • 0 DCY
U0411 Invalid Data Received From Drive Motor Control Module "A"
  • DLC of received message shorter than specification
  • Or
  • Consecutive messages with same message counter >= 5
  • Or
  • Checksum invalid
  • Battery state HV_OFF
  • Or
  • PRECHARGE
  • Or
  • HV_ON
  • Or
  • EMERGENCY_OFF
  • CAN active
  • 1 time
  • Or
  • Message cycle
  • Or
  • 1 times
  • 2 DCY
  • Or
  • 1 DCY
  • Or
  • 0 DCY
U0415 Invalid Data Received From Anti-Lock Brake System (ABS) Control Module
  • DLC of received message shorter than specification
  • Or
  • Consecutive messages with same message counter >= 5
  • Or
  • Checksum invalid
  • DLC of received message shorter than specification
  • Battery state HV_OFF
  • Or
  • PRECHARGE
  • Or
  • HV_ON
  • Or
  • EMERGENCY_OFF
  • 3 times
  • 2 DCY
U0416 Invalid Data Received From Vehicle Dynamics Control Module
  • DLC of received message shorter than specification
  • Or
  • Consecutive messages with same message counter >= 5
  • Or
  • Checksum invalid
  • Battery state HV_OFF
  • Or
  • PRECHARGE
  • Or
  • HV_ON
  • Or
  • EMERGENCY_OFF
  • CAN active
  • 1 time
  • Or
  • Message cycle
  • Or
  • 1 times
  • 2 DCY
  • Or
  • 1 DCY
  • Or
  • 0 DCY
U0424 Invalid Data Received From HVAC Control Module
  • DLC of received message shorter than specification
  • Or
  • Consecutive messages with same message counter >= 5
  • Or
  • Checksum invalid
  • Battery state HV_OFF
  • Or
  • PRECHARGE
  • Or
  • HV_ON
  • Or
  • EMERGENCY_OFF
  • CAN active
  • 1 time
  • Or
  • Message cycle
  • Or
  • 1 times
  • 2 DCY
  • Or
  • 1 DCY
  • Or
  • 0 DCY
U0447 Invalid Data Received From Gateway "A"
  • DLC of received message shorter than specification
  • Or
  • Consecutive messages with same message counter >= 5
  • Or
  • Checksum invalid
  • DLC of received message shorter than specification
  • Battery state HV_OFF
  • Or
  • PRECHARGE
  • Or
  • HV_ON
  • Or
  • EMERGENCY_OFF
  • 1 time
  • 2 DCY
U049C Invalid Data Received From Battery Charger Control Module
  • DLC of received message shorter than specification
  • Or
  • Consecutive messages with same message counter >= 5
  • Or
  • Checksum invalid
  • Battery state HV_OFF
  • Or
  • PRECHARGE
  • Or
  • HV_ON
  • Or
  • EMERGENCY_OFF
  • CAN active
  • 1 time
  • Or
  • Message cycle
  • Or
  • 1 times
  • 2 DCY
  • Or
  • 1 DCY
  • Or
  • 0 DCY
U04A1 Invalid Data Received From Hybrid/EV Battery Interface Control Module "A"
  • DLC of received message shorter than specification
  • Or
  • Consecutive messages with same message counter >= 5
  • Or
  • Checksum invalid
  • Battery state HV_OFF
  • Or
  • PRECHARGE
  • Or
  • HV_ON
  • Or
  • EMERGENCY_OFF
  • CAN active
  • 1 time
  • Or
  • Message cycle
  • Or
  • 1 times
  • 2 DCY
  • Or
  • 1 DCY
  • Or
  • 0 DCY
U04A2 Invalid Data Received From Hybrid/EV Battery Interface Control Module "B"
  • DLC of received message shorter than specification
  • Or
  • Consecutive messages with same message counter >= 5
  • Or
  • Checksum invalid
  • Battery state HV_OFF
  • Or
  • PRECHARGE
  • Or
  • HV_ON
  • Or
  • EMERGENCY_OFF
  • CAN active
  • 1 time
  • Or
  • Message cycle
  • Or
  • 1 times
  • 2 DCY
  • Or
  • 1 DCY
  • Or
  • 0 DCY
U04A3 Invalid Data Received From Hybrid/EV Battery Interface Control Module "C"
  • DLC of received message shorter than specification
  • Or
  • Consecutive messages with same message counter >= 5
  • Or
  • Checksum invalid
  • Battery state HV_OFF
  • Or
  • PRECHARGE
  • Or
  • HV_ON
  • Or
  • EMERGENCY_OFF
  • CAN active
  • 1 time
  • Or
  • Message cycle
  • Or
  • 1 times
  • 2 DCY
  • Or
  • 1 DCY
  • Or
  • 0 DCY
U04A5 Invalid Data Received From Hybrid/EV Battery Interface Control Module "E"
  • DLC of received message shorter than specification
  • Or
  • Consecutive messages with same message counter >= 5
  • Or
  • Checksum invalid
  • Battery state HV_OFF
  • Or
  • PRECHARGE
  • Or
  • HV_ON
  • Or
  • EMERGENCY_OFF
  • CAN active
  • 1 time
  • Or
  • Message cycle
  • Or
  • 1 times
  • 2 DCY
  • Or
  • 1 DCY
  • Or
  • 0 DCY
U04A6 Invalid Data Received From Hybrid/EV Battery Interface Control Module "F"
  • DLC of received message shorter than specification
  • Or
  • Consecutive messages with same message counter >= 5
  • Or
  • Checksum invalid
  • Battery state HV_OFF
  • Or
  • PRECHARGE
  • Or
  • HV_ON
  • Or
  • EMERGENCY_OFF
  • CAN active
  • 1 time
  • Or
  • Message cycle
  • Or
  • 1 times
  • 2 DCY
  • Or
  • 1 DCY
  • Or
  • 0 DCY
U04A7 Invalid Data Received From Hybrid/EV Battery Interface Control Module "G"
  • DLC of received message shorter than specification
  • Or
  • Consecutive messages with same message counter >= 5
  • Or
  • Checksum invalid
  • Battery state HV_OFF
  • Or
  • PRECHARGE
  • Or
  • HV_ON
  • Or
  • EMERGENCY_OFF
  • CAN active
  • 1 time
  • Or
  • Message cycle
  • Or
  • 1 times
  • 2 DCY
  • Or
  • 1 DCY
  • Or
  • 0 DCY
U04A8 Invalid Data Received From Hybrid/EV Battery Interface Control Module "H"
  • DLC of received message shorter than specification
  • Or
  • Consecutive messages with same message counter >= 5
  • Or
  • Checksum invalid
  • Battery state HV_OFF
  • Or
  • PRECHARGE
  • Or
  • HV_ON
  • Or
  • EMERGENCY_OFF
  • CAN active
  • 1 time
  • Or
  • Message cycle
  • Or
  • 1 times
  • 2 DCY
  • Or
  • 1 DCY
  • Or
  • 0 DCY
U059B Invalid Data Received From Hybrid/EV Battery Pack Sensor Module
  • DLC of received message shorter than specification
  • Or
  • Consecutive messages with same message counter >= 5
  • Or
  • Checksum invalid
  • Battery state HV_OFF
  • Or
  • PRECHARGE
  • Or
  • HV_ON
  • Or
  • EMERGENCY_OFF
  • CAN active
  • 1 time
  • Or
  • Message cycle
  • Or
  • 1 times
  • 2 DCY
  • Or
  • 1 DCY
  • Or
  • 0 DCY