| P0560 |
System Voltage |
- Voltage sensor 1 - voltage sensor 3 > 4.5 V
|
- EBBC state running
- Or
- Shutdown
- Vehicle speed > 1.8 m/s
- Electric motor not controlled
|
|
|
| P0562 |
System Voltage Low |
|
- EBBC state running
- Or
- Shutdown
|
|
|
| P0563 |
System Voltage High |
- Voltage sensor 3 > 19.8 V
|
- EBBC state running
- Or
- Shutdown
- Vehicle speed > 1.8 m/s
|
|
|
| P057B |
Brake Pedal Position Sensor "A" Circuit Range/Performance |
- BPTS A gradient < -2, 000 mm/s
|
|
|
|
- BPTS A PWM frequency < 879.3 1/s
- Or
- BPTS A PWM frequency > 1127.17 1/s
|
- EBBC state running
- Or
- Shutdown
|
|
- BPTS A PWM duty cycle < 7.32%
- Or
- BPTS A PWM duty cycle > 92.83%
|
| P057C |
Brake Pedal Position Sensor "A" Circuit Low |
- BPTS A signal line rising or falling edge of BPTS A PWM < 0.3 V
- Not detected
|
- EBBC state running
- Or
- Shutdown
|
|
|
| P057D |
Brake Pedal Position Sensor "A" Circuit High |
- BPTS A signal line rising or falling edge of BPTS A PWM > 4.7 V
- Not detected
|
- EBBC state running
- Or
- Shutdown
|
|
|
| P05DC |
Brake Pedal Position Sensor "B" Circuit Range/Performance |
- BPTS B gradient < -2, 000 mm/s
|
|
|
|
- BPTS B PWM frequency < 879.3 1/s
- Or
- BPTS B PWM frequency > 1127.17 1/s
|
- EBBC state running
- Or
- Shutdown
|
|
- BPTS B PWM duty cycle < 7.32%
- Or
- BPTS B PWM duty cycle > 92.83%
|
| P05DD |
Brake Pedal Position Sensor "B" Circuit Low |
- BPTS B signal line rising or falling edge of BPTS B PWM < 0.3 V not detected
|
- EBBC state running
- Or
- Shutdown
|
|
|
| P05DE |
Brake Pedal Position Sensor "B" Circuit High |
- BPTS B signal line rising or falling edge of BPTS B PWM > 4.7 V not detected
|
- EBBC state running
- Or
- Shutdown
|
|
|
| P05E0 |
Brake Pedal Position Sensor "A"/"B" Correlation |
|
- BPTS A
- Or
- BPTS B > 42 mm > 42 mm
|
|
|
|
|
- BPTS A signal
- BPTS B signal <= 42 mm <= 42 mm
|
- BPTS A + BPTS B) / 2 > 0.6 mm
- (BPTS A + BPTS B) / 2 < 1.5 mm
|
- EBBC state running
- Or
- Shutdown
- Vehicle speed > 2 m/s
- Brake pedal not applied
|
|
|
| P0604 |
Internal Control Module Random Access Memory (RAM) Error |
- Multi bit failure detected true
- Or
- Coupling failure detected true
- Or
- Address decoder test detects an error true
|
|
|
|
- March 13 test detects a fault true
|
|
|
- RAM cell <>'0'
- Or
- SRAM cell <> '0'
|
|
- Number of detected single-bit errors > 2
|
- EBBC state running
- Or
- Shutdown
|
|
| P0607 |
Control Module Performance |
- Baud rate timing check not ok
- Or
- Mask register check not ok
- Or
- Arbitration register check not ok
|
|
|
|
- Communication time out between CAN-core and RAM detected true
|
|
- Data abort occurred true
- Or
- Pre fetch abort occurred true
- Or
- Undefined instruction occurred true
|
|
|
|
- Current start time of a task > ideal start time + 5%
|
|
- ADC reference voltage
- Or
- ADC reference voltage < 1.145 V > 1.345 V
|
|
|
|
- EBBC state init
- Watchdog trigger missed
- Or
- Watchdog trigger timing wrong
|
|
|
- Error pin event counter not incremented
|
|
|
- HETOFF1 - failure detected flag true
|
|
|
|
- HETTU status - pointer error flag true
|
- HETTU status - bus error flag true
|
- HETTU status - busy error flag true
|
- INTOFF0 - failure detected flag true
|
- Watchdog detects a missing task true
|
- Defined frequency - calculated frequency | / defined frequency > 5%
|
- EBBC state running
- Or
- Shutdown
|
|
|
- Charge-pump failure bit true
- Or
- Clock-input-signal failure bit true
- Or
- Internal-oscillator-circuit failure bit true
|
|
|
- Voltage comparator test error flag set
|
|
- EEPROM cell is empty true
|
|
- Task exception occurred true
|
- EBBC state running
- Or
- Shutdown
|
|
- PDUR initialization false
|
|
|
- PDU buffer overrun detected
|
|
- Number of EEPROM cells where BPTS calibration value is empty >= 1
|
|
|
|
- EEPROM cell is empty true
|
- Check-word at begin of stack has changed
- Or
- Check-word at end of stack has changed true
|
- EBBC state running
- Or
- Shutdown
|
|
- Not supported software interrupt occurred true
- Or
- Non implemented interrupt occurred true
- Or
- Interrupt lock release is called without previous lock true
- Or
- Not all interrupts are released true
- Or
- Interrupt lock time > 0.07 ms
|
|
- Voltage pre-regulator mode failure bit set
|
- EBBC state running
- Or
- Shutdown
|
|
|
| P060B |
Internal Control Module A/D Processing Performance |
- Number of conversions which could not be finished in time >= 10
|
|
|
|
- Difference between the two ADC measurements per channel > 540 digits
|
|
|
| P060C |
Internal Control Module Main Processor Performance |
|
|
|
|
- Double bit error detected
- Or
- Number of detected single bit errors > 1
|
|
|
|
|
|
|
|
|
- EBBC state running
- Or
- Shutdown
|
|
- No NMI occurred true
- Or
- Not expected NMI occurred true
|
|
| P0610 |
Control Module Vehicle Options Error |
|
- EBBC state running
- Or
- Shutdown
|
|
|
| P062F |
Internal Control Module EEPROM Error |
- Read failure occurred true
|
|
|
|
- Stored customer ID <> expected customer ID
|
|
- PSW end marker has not been found true
|
- PDM data field size to allocate > available space in EEPROM
|
|
|
- EEPROM data field size stored <> data field size configuration in software
|
|
|
- Writing operation read data > 25.0 ms
- Not equal to written data
|
- EBBC state running
- Or
- Shutdown
|
|
|
|
|
|
- Read failure occurred true
|
|
|
|
| U0001 |
High Speed CAN Communication Bus |
|
|
|
|
| U0002 |
High Speed CAN Communication Bus Performance |
- No CAN 2 message received
|
|
|
|
| U0100 |
Lost Communication With ECM/PCM "A" |
- Data length of engine ECU CAN message is not correct > 5
- A CAN messages from engine ECU was not received > 5
|
|
|
|
| U0122 |
Lost Communication With Vehicle Dynamics Control Module |
- A CAN messages from BSCM ECU was not received > 25
|
|
|
|
| U0167 |
Lost Communication With Vehicle Immobilizer Control Module |
|
|
|
|
| U0401 |
Invalid Data Received From ECM/PCM "A" |
- Recalculated CRC does not match the received CRC > 0
|
|
|
|
- Message counters of engine ECU CAN messages are not periodically incremented > 4
|
|
| U0416 |
Invalid Data Received From Vehicle Dynamics Control Module |
- Data length of gateway ECU CAN message is not correct > 10
- A CAN messages from gateway ECU was not received >10
|
|
|
|
- Message counters of BSCM ECU CAN messages are not periodically incremented > 25
|
|
- Recalculated CRC does not match the received CRC > 0
|
|
| U0426 |
Invalid Data Received From Vehicle Immobilizer Control Module |
- Received VIN is at initialization value true
|
|
|
|
| U1013 |
Control Module Not Coded |
- EEPROM variant code contained in SW false
|
|
|
|
- EEPROM variant information empty
|
| U103E |
Brake Booster Control Module No Communication |
- Data length of EBBC ECU CAN message is not correct > 3
|
|
|
|
- No CAN messages from EBBC ECU are received by AHA > 10
|
|
| U103F |
Brake Booster Control Module Implausible Signal |
- Message counters of EBBC ECU CAN messages are not periodically incremented > 5
|
|
|
|
- Recalculated CRC does not match the received CRC > 3
|
| U10B8 |
Local Data Bus Faulty |
- CAN 1 bus state bus off
- No CAN 1 message received > 10
|
|
|
|
- No CAN 2 message detected > 10
|
|
| U111D |
Brake Press. Accum. Control Module No Communication |
- Data length of AHA ECU CAN message is not correct > 10
- A CAN messages from AHA ECU was not received > 10
|
|
|
|
| U111E |
Brake Press. Accum. Control Module Implausible Signal |
- Message counters of AHA ECU CAN messages are not periodically incremented > 4
|
|
|
|
- Recalculated CRC does not match the received CRC > 3
|
|