Home >> Audi >> 2017 >> S6 Premium Plus >> Repair and Diagnosis (Single Page) >> Heating, Ventilation & A/C (HVAC) >> HVAC Control Systems >> Air Conditioning >> 87 Air Conditioning >> Refrigerant Circuit >> System Overview - Refrigerant Circuit >> System Overview - Refrigerant Circuit With Electrically-Driven A/C Compressor (With Or Without Battery Cooling Module)
July 1: So it begins. Don't worry, this is not in the correct legal jurisdiction!

System Overview - Refrigerant Circuit With Electrically-Driven A/C Compressor (With Or Without Battery Cooling Module)

NOTE:

The arrows indicate the refrigerant flow direction.

The following illustration shows a refrigerant circuit with an expansion valve and a second evaporator for cooling the battery and an inner heat exchanger as an example.

The layout of the refrigerant circuit is vehicle-specific. Refer to REFRIGERANT CIRCUIT [For engine(s) CTUA, CAED, CREH, CEUC, CTGE, CREC, CYNB, CPNB]

HD  = High Pressure Side

ND  = Low Pressure Side

Fig 1: Refrigerant Circuit With Electrically-Driven A/C Compressor (With Or Without Battery Cooling Module) Component Locations
GWWA87-11246Courtesy of AUDI OF AMERICA, LLC
  1. Electrically-Driven A/C Compressor
  2. Pressure Relief Valve
  3. Condenser
    • With receiver/dryer and dryer cartridge.
  4. Receiver/Dryer
    • Is a component of the condenser
  5. Refrigerant Pressure Sensor
  6. Service Connection - High Pressure Side
    • With closure cap.
  7. Refrigerant Line with Inner Heat Exchanger
  8. Refrigerant Shut-Off Valve
  9. Expansion Valve
    • On the heater and A/C unit evaporator
  10. Front Evaporator
    • Heater and A/C unit evaporator
  11. Expansion Valve with Shut-Off Valve
  12. Evaporator
    • Evaporator in the battery cooling module
    • Only on vehicles with a battery cooling module for the Hybrid Battery Unit -AX1-.
  13. Service Connection - Low Pressure Side
    • With closure cap