Engine Control Module, 2014 - 2015 MY --

DTC / Description Monitor Strategy Description Malfunction Criteria and Threshold Value Secondary Parameters with Enable Conditions Monitoring Time Length MIL Illum. Component Diagnostic Procedure
P000A  Intake Camshaft Position Slow Response Bank 1 VVT Actuator Intake Rationality Check
  • Adjustment angle difference >= 1.0; < 10.0° CRK
  • Modelled oil temperature -40 - 160° C
  • Engine speed 608 - 6, 016 RPM
  • Set point change > 25.0° CRK
  • Dynamic diagnosis timer >= 0.95 - 4.0 s
  • 0.0 (FTP75: 350.0) s
  • Continuous
  • 2 DCY
-- Check the Camshaft Adjustment Valve 1 -N205-. Refer to Camshaft Adjustment Valve 1 - N205-, CHECKING .
P000B  Exhaust Camshaft Position Slow Response Bank 1 VVT Actuator Exhaust Rationality Check
  • Adjustment angle difference >= 1.0; < 10.0° CRK
  • Modelled oil temperature -40 - 160° C
  • Engine speed 608 - 6, 016 RPM
  • Set point change > 25.0° CRK
  • Dynamic diagnosis timer >= 0.95 - 4.0 s
  • 0.0 (FTP75: 350.0) s
  • continuous
  • 2 DCY
-- Check the Exhaust Camshaft Adjustment Valve 1 -N318-. Refer to Exhaust Camshaft Adjustment Valve 1 - N318-, CHECKING .
P0010 Intake Camshaft Position Actuator Circuit Open Bank 1 VVT Actuator Intake Open Circuit
  • Output voltage, lower range 1.92 - 2.21 V
  • Actuator commanded off
  • 2.0 s
  • Continuous
  • 2 DCY
-- Check the Camshaft Adjustment Valve 1 -N205-. Refer to Camshaft Adjustment Valve 1 - N205-, CHECKING .
P0011  Intake Camshaft Position Timing - Over-Advanced Bank 1 VVT Actuator Intake Rationality Check
  • Camshaft position deviation > 10.0° CRK
  • Modeled oil temperature -40 - 160° C
  • Engine speed 608 - 6, 016 RPM
  • Camshaft adjustment n.a.
  • Catalyst heating n.a.
  • 0.0 (FTP75: 120.0) s
  • multiple
  • 2 DCY
-- Check the Camshaft Adjustment Valve 1 -N205-. Refer to Camshaft Adjustment Valve 1 - N205-, CHECKING .
P0014  Exhaust Camshaft Position Timing - Over-Advanced Bank 1 VVT Actuator Exhaust Rationality Check
  • Camshaft position deviation > 10.0° CRK
  • Modeled oil temperature -40 - 160° C
  • Engine speed 608 - 6, 016 RPM
  • Camshaft adjustment n.a.
  • Catalyst heating n.a.
  • 0.0 (FTP75: 120.0) s
  • Multiple
  • 2 DCY
-- Check the Exhaust Camshaft Adjustment Valve 1 -N318-. Refer to Exhaust Camshaft Adjustment Valve 1 - N318-, CHECKING .
P0016 Crankshaft Position - Camshaft Position Intake - Correlation Camshaft Position/Crankshaft Position Intake - Correlation Adaptation Value Monitoring
  • Adapted value for each edge of the target wheel < -14.0° CRK
  • Or
  • Adapted value for each edge of the target wheel > 14.0° CRK
  • Camshaft adjustment active (exhaust side) engine speed 288 - 4, 000 RPM
  • Modeled oil temperature >= -15° C
  • Modeled oil temperature <= 160° C
  • Engine speed < 8, 160 RPM
  • Diff. actual exhaust camshaft position vs. previous camshaft position @ reference signal edge < 2.0° CRK
  • And
  • Case 1:
  • Ignition off
  • Engine speed > 380 RPM
  • Engine stalling >= 1.0 s
  • Or
  • Case 2:
  • Engine speed >= 380 RPM
  • Or
  • Engine running
  • And
  • Engine stalling >= 5.0 s
  • Or
  • Case 3:
  • Backwards rotation not detected
  • Or
  • Case 4:
  • Engine speed >= 300 RPM
  • Engine stopped
  • 720° CRK
  • Once / DCY
  • 2 DCY
-- Check the Camshaft Adjustment Valve 1 -N205-. Refer to Camshaft Adjustment Valve 1 - N205-, CHECKING .-- Check the Engine Speed Sensor -G28-. Refer to Engine Speed Sensor - G28-, CHECKING .
P0017 Crankshaft Position - Camshaft Position Exhaust - Correlation Camshaft Position/Crankshaft Position Exhaust - Correlation Adaptation Value Monitoring
  • Adapted value for each edge of the target wheel < -14.0° CRK
  • Or
  • Adapted value for each edge of the target wheel > 14.0° CRK
  • Camshaft adjustment active (exhaust side) engine speed 288 - 4, 000 RPM
  • Modeled oil temperature >= -15° C
  • Modeled oil temperature <= 160° C
  • Engine speed < 8, 160 RPM
  • Diff. actual exhaust camshaft position vs. previous camshaft position @ reference signal edge < 2.0° CRK
  • And
  • Case 1:
  • Ignition off
  • Engine speed > 380 RPM
  • Engine stalling >= 1.0 s
  • Or
  • Case 2:
  • Engine speed >= 380 RPM
  • Or
  • engine running
  • And
  • Engine stalling >= 5.0 s
  • Or
  • Case 3:
  • Backwards rotation not detected
  • Or
  • Case 4:
  • Engine speed >= 300 RPM
  • Engine stopped
  • 720° CRK
  • Once / DCY
  • 2 DCY
-- Check the Camshaft Adjustment Valve 1 -N205-. Refer to Camshaft Adjustment Valve 1 - N205-, CHECKING .-- Check the Engine Speed Sensor -G28-. Refer to Engine Speed Sensor - G28-, CHECKING .
P0030 HO2S Heater Control Circuit Bank 1 Sensor 1 Oxygen Sensors Heater Front Open Circuit
  • O2S upstream heater voltage, lower range 1.92 - 2.21 V
  • O2S upstream heater voltage, upper range 2.85 - 3.25 V
 
  • 2.5 s
  • Continuous
  • 2 DCY
-- Check the Oxygen Sensor 1 Before Catalytic Converter -GX10-. Refer to Oxygen Sensor 1 Before Catalytic Converter - GX10-, CHECKING .
P0031 HO2S Heater Control Circuit Low Bank 1 Sensor 1 Oxygen Sensors Heater Front Short To Ground
  • O2S upstream heater voltage, lower range 1.92 - 2.21 V
 
  • 2.5 s
  • Continuous
  • 2 DCY
-- Check the Oxygen Sensor 1 Before Catalytic Converter -GX10-. Refer to Oxygen Sensor 1 Before Catalytic Converter - GX10-, CHECKING .
P0032 HO2S Heater Control Circuit High Bank 1 Sensor 1 Oxygen Sensors Heater Front Short To Battery Voltage
  • O2S upstream heater driver temperature > 160.0 - 200.0° C
  • Or
  • O2S upstream heater driver output current > 8.0 - 12.0 A
  • EGT @ O2S front >= -273° C
  • Actuator commanded on
  • 2.5 s
  • Continuous
  • 2 DCY
-- Check the Oxygen Sensor 1 Before Catalytic Converter -GX10-. Refer to Oxygen Sensor 1 Before Catalytic Converter - GX10-, CHECKING .
P0036 HO2 Sensor Heater Control Circuit Bank 1 Sensor 2 Oxygen Sensors Heater Rear Open Circuit
  • O2S downstream heater voltage, lower range 1.92 - 2.21 V
  • O2S downstream heater voltage, upper range 2.85 - 3.25 V
  • Engine not in start process
  • 2.5 s
  • Continuous
  • 2 DCY
-- Check the Oxygen Sensor 1 After Catalytic Converter -GX7-. Refer to Oxygen Sensor 1 After Catalytic Converter - GX7-, CHECKING .
P0037 HO2 Sensor Heater Control Circuit Low Bank 1 Sensor 2 Oxygen Sensors Heater Rear Short To Ground
  • O2S downstream heater voltage, lower range 1.92 - 2.21 V
  • Engine not in start process
  • 2.5 s
  • Continuous
  • 2 DCY
-- Check the Oxygen Sensor 1 After Catalytic Converter -GX7-. Refer to Oxygen Sensor 1 After Catalytic Converter - GX7-, CHECKING .
P0038 HO2S Heater Control Circuit High Bank 1 Sensor 2 Oxygen Sensors Heater Rear Short To Battery Voltage
  • O2S downstream heater driver temperature > 160.0 - 200.0° C
  • Or
  • O2S downstream heater driver output current > 8.0 - 12.0 A
  • EGT @ O2S rear (binary) >= -273
  • Actuator commanded on
  • Engine not in start process
  • 2.5 s
  • Continuous
  • 2 DCY
-- Check the Oxygen Sensor 1 After Catalytic Converter -GX7-. Refer to Oxygen Sensor 1 After Catalytic Converter - GX7-, CHECKING .
P0045 Turbocharger / Supercharger Boost Control "A" Circuit / Open Turbocharger Boost Pressure Control Valve Open Circuit
  • Bypass valve driver load resistance > 200.0 kΩ
  • Deviation between actual and filtered boost pressure actuator position <= 5.0%
  • Boost pressure actuator controller not active
  • Time delay > 1.0 s
  • 0.4 s
  • Continuous
  • 2 DCY
-- Check the Charge Air Pressure Actuator -V465- / Charge Air Pressure Actuator Position Sensor -G581-. Refer to Charge Air Pressure Actuator - V465- / Charge Air Pressure Actuator Position Sensor - G581-, CHECKING .
P0068 MAP/MAF - Throttle Position Correlation Leak to Intake Manifold Rationality Check
  • Difference between target intake manifold pressure and actual intake manifold pressure < -15.0 - -10.0 kPa
  • Time after engine start > 5.0 s
  • Barometric pressure > 73.0 - 105.0 kPa
  • Engine speed > 576 - 512 RPM
  • Engine speed < 3, 000 RPM
  • IAT @ intake manifold > -48° C
  • ECT @ cylinder head > -48° C
  • Difference between engine speed and filtered engine speed < 8, 160 RPM
  • Difference between MAF set point and filtered MAF set point < 15.01 mg/stk
  • Throttle actuator commanded on
  • Modeled pressure quotient 0.10 - 0.60 [-]
  • Gradient of intake manifold pressure >= -199.90; <= 199.90 kPa/s
  • Vehicle speed <= 1 mph
  • 5.0 s
  • Continuous
  • 2 DCY
-- Check the Intake system for vacuum leaks, make sure oil dipstick is pushed properly into place.-- Check the Intake Manifold Sensor -GX9-. Refer to Intake Manifold Sensor - GX9-, CHECKING .-- Check the Throttle Valve Control Module -GX3-. Refer to Throttle Valve Control Module - GX3-, CHECKING .
P0070 Ambient Air Temperature Sensor Circuit CAN: Ambient Air Temperature Sensor Short To Battery Voltage Or Open Circuit
  • AAT sensor voltage (hardware values) > 4.50 V
 
  • 2.0 s
  • Continuous
  • 2 DCY
-- Check the Outside Air Temperature Sensor -G17-. Refer to Outside Air Temperature Sensor - G17-, CHECKING .
P0071 Ambient Air Temperature Sensor Range / Performance Ambient Air Temperature Sensor Cross Check
  • High side:
  • Diff. AAT @ cold start vs. IAT @ manifold @ cold start > 25 K
  • Diff. AAT @ cold start vs. ECT @ radiator outlet @ cold start > 25 K
  • Or
  • Low side:
  • Diff. IAT @ manifold @ cold start vs. AAT @ cold start > 25.0 K
  • Diff. ECT @ radiator outlet @ cold start vs. AAT @ cold start > 25.0 K
  • Engine off time >= 360.0 min
  • Engine off time plausible
  • Time after engine start < 1, 400.0 s
  • Depending on temperature slope:
  • Diff. actual vs previous IAT < 256.0 K
  • Diff. actual vs previous ECT @ cylinder head < 256.0 K
  • Diff.. actual vs previous ECT@ radiator outlet < 256.0 K
  • Diff. actual vs previous AAT < 256.0 K
  • For time >= 1.0 s
  • 0.1 s
  • Once / DCY
  • 2 DCY
-- Check the Outside Air Temperature Sensor -G17-. Refer to Outside Air Temperature Sensor - G17-, CHECKING .
P0072 Ambient Air Temperature Sensor Circuit Low CAN: Ambient Air Temperature Sensor Short To Ground
  • AAT sensor voltage < 0.10 V
 
  • 2.0 s
  • Continuous
  • 2 DCY
-- Check the Outside Air Temperature Sensor -G17-. Refer to Outside Air Temperature Sensor - G17-, CHECKING .
P0087 Fuel Rail/System Pressure - Too Low Fuel System Pressure Sensor, High Pressure Side Out Of Range Low
  • Deviation between reference fuel pressure set point and current fuel pressure > 2, 000.10 kPa
  • Case: 1
  • Fuel mass controller output -50.0 - 50.0%
  • High pressure controller output > 30 mg
  • Fuel pressure < 3500.31 kPa
  • Case 2:
  • Fuel pump at max limit
  • Mass fuel flow set point < 1, 389.0 mg/stk
  • Fuel pressure < 34, 777.60 kPa
  • Engine speed > 600 RPM
  • EVAP purge adaptation < 22
  • ECT >= 63 °C
  • IAT < 90 °C
  • Lambda control closed loop
  • 4.5 s
  • Continuous
  • 2 DCY
-- Check the fuel pressure, refer to the repair information for proper procedures.-- Check the Fuel Pressure Sensor -G247-. Refer to Fuel Pressure Sensor - G247-, CHECKING .-- Check the Fuel Metering Valve -N290-. Refer to Fuel Metering Valve - N290-, CHECKING .-- Check the Fuel Delivery Unit -GX1- / Fuel Pump Control Module -J538-. Refer to Fuel Delivery Unit -GX1- / Fuel Pump Control Module -J538-, CHECKING .
Fuel System Pressure Sensor, High Pressure Side Rationality Check Low
  • Fuel mass controller output -50.0 - 50.0%
  • And
  • High pressure controller output > 35.0 mg
  • And
  • Deviation between fuel pressure set point
  • And
  • Current fuel pressure > 2, 000.10 kPa
  • And
  • Fuel pressure >= 3, 500.31 kPa
  • Engine speed 608 - 6, 816 RPM
  • Mass fuel flow set point 15.01 - 1, 389.0 mg/stk
  • For time after request for mass fuel flow set point >= 5.0 s
  • Engine start not active
  • Time after engine start > 10.0 s
  • Engine warm-up n.a.
  • Catalyst heating not active
  • Full load n.a.
  • Catalyst purge n.a.
  • Lambda control n.a.
  • Evap purge functionality diagnosis n.a.
  • And
  • Choice of:
  • Canister load <= n.a. [-]
  • Or
  • Evap purge valve n.a.
P0092 Fuel Pressure Regulator 1 Control Circuit High Fuel Control Valve Short To Battery Voltage
  • Current low side (hardware values) > 13.5 - 17.0 A
  • Ignition on
  • Or
  • Ignition off (during ECM keep alive-time)
  • And
  • Actuator commanded on
  • 0.8 s
  • Continuous
  • 2 DCY
-- Check the Fuel Metering Valve -N290-. Refer to Fuel Metering Valve - N290-, CHECKING .
  • Voltage high side (hardware values) < 1.92 - 2.21 V
  • Ignition on
  • Or
  • Ignition off (during ECM keep alive-time)
  • And
  • Actuator commanded off
P00B7 Engine Coolant Flow Low / Performance Rotary Coolant Valve Functional Check
  • Diff. previous and actual position of RVC < 4.0° [-]
  • ECT @ cylinder head > 11° C
  • RCV position 0.0 - 270.0° [-]
  • Diff. previous actual and target position of RCV > 5.0° [-]
  • And
  • RCV adaptation finished
  • Or
  • RCV adaptation not active
  • 3.0 s
  • continuous
  • 2 DCY
-- Check coolant system for leaks or damage.-- Check the Engine Temperature Control Actuator -N493-. Refer to Engine Temperature Control Actuator - N493-, CHECKING ..
P0106 Manifold Absolute Pressure / Barometric Pressure Circuit Range / Performance Manifold Pressure Sensor By Engine Standing: Rationality Check During Engine Off
  • Diff. barometric pressure vs. intake manifold pressure >= 8.50 kPa
  • Or
  • Diff. upstream throttle pressure vs. intake manifold pressure >= 8.50 kPa
  • Case 1:
  • Engine stop during DCY
  • Engine stopped
  • Vehicle speed < 1 mph
  • Engine stop >= 5.0 s
  • For time >= 10.0 s
  • Case 2:
  • Engine stop at start of DCY
  • Engine stop stopped
  • Vehicle speed < 1 mph
  • Engine stop >= 5.0 s
  • 3.0 s
  • Continuous
  • 2 DCY
-- Check the Intake Manifold Sensor -GX9-. Refer to Intake Manifold Sensor - GX9-, CHECKING .
Rationality Check During ECM Keep Alive-Time
  • Diff. upstream throttle pressure @ engine off vs. intake manifold pressure @ engine off > 8.50 kPa
  • And
  • Diff. intake manifold pressure @ engine stop vs. intake manifold pressure @ idle speed < n.a. kPa
  • Or
  • Diff. barometric pressure vs. intake manifold pressure >= 8.50 kPa
  • And
  • Diff. intake manifold pressure @ engine stop vs. intake manifold pressure @ idle speed < n.a. kPa
  • Or
  • Intake manifold pressure (raw value) < 0.0; > 543.40 kPa
  • Engine stop
  • Vehicle speed < 1 mph
  • Delay time in ECM keep alive-time > 10.0 s
  • Engine stop >= 5.0 s
  • Barometric pressure sensor voltage 0.20 - 4.80 V
  • Intake manifold pressure sensor voltage 0.20 - 4.80 V
  • Turbocharger boost pressure sensor voltage 0.20 - 4.80 V
P0107 Manifold Absolute Pressure / Barometric Pressure Circuit Low Manifold Pressure Sensor Short To Ground
  • Intake manifold pressure sensor voltage < 0.20 V
 
  • 0.5 s
  • Continuous
  • 2 DCY
-- Check the Intake Manifold Sensor -GX9-. Refer to Intake Manifold Sensor - GX9-, CHECKING .
P0108 Manifold Absolute Pressure/Barometric Pressure Circuit high Manifold Pressure Sensor Short To Battery Voltage
  • Intake manifold pressure sensor voltage > 4.80 V
 
  • 0.5 s
  • Continuous
  • 2 DCY
-- Check the Intake Manifold Sensor -GX9-. Refer to Intake Manifold Sensor - GX9-, CHECKING .
P0111 Intake Air Temperature Sensor 1 Circuit Range / Performance Intake Air Temperature Sensor @ Manifold Cross Check
  • High side:
  • Diff. IAT @ manifold @ cold start vs. AAT @ cold start > 25.0 K
  • Diff. IAT @ manifold @ cold start vs. ECT @ radiator outlet @ cold start > 25.0 K
  • Or
  • Low side:
  • Diff. AAT @ cold start vs. IAT @ manifold @ cold start > 25.0 K
  • Diff. ECT @ radiator outlet @ cold start vs. IAT @ manifold @ cold start > 25.0 K
  • Engine off time >= 360.0 min
  • Engine off time plausible time after engine start <= 1, 400.0 s
  • Depending on temperature slope:
  • Diff. actual vs previous IAT < 256.0 K
  • Diff. actual vs previous ECT@ cylinder head < 256.0 K
  • Diff. actual vs previous ECT@ radiator outlet < 256.0 K
  • Diff. actual vs previous AAT < 256.0 K
  • For time >= 1.0 s
  • 0.1 s
  • Once / DCY
  • 2 DCY
-- Check the Intake Manifold Sensor -GX9-. Refer to Intake Manifold Sensor - GX9-, CHECKING .
P0112 Intake Air Temperature Sensor 1 Circuit Low Intake Air Temperature Sensor @ Manifold Short To Ground
  • IAT sensor voltage < 0.10 V
 
  • 2.0 s
  • Continuous
  • 2 DCY
-- Check the Intake Manifold Sensor -GX9-. Refer to Intake Manifold Sensor - GX9-, CHECKING .
P0113 Intake Air Temperature Sensor 1 Circuit High Intake Air Temperature Sensor @ Manifold Short To Battery Voltage
  • IAT sensor voltage > 4.50 V
 
  • 2.0 s
  • Continuous
  • 2 DCY
-- Check the Intake Manifold Sensor -GX9-. Refer to Intake Manifold Sensor - GX9-, CHECKING .
P0116 Engine Coolant Temperature Sensor 1 Circuit Range/Performance Engine Coolant Temperature Sensor @ Cylinder Head Rationality Check
  • Rationality check inappropriately low:
  • Diff. min temperature of cross check sensors vs. ECT @ cylinder head @ engine start >= 25° C
  • Rationality check inappropriately low:
  • Cross checks finished
  • 1.0 s
  • Once / DCY
  • 2 DCY
-- Check the Engine Coolant Temperature Sensor -G62-. Refer to Engine Coolant Temperature Sensor - G62-, CHECKING .
  • Rationality check high:
  • ECT @ cylinder head @ engine start > 40 - 80° C
  • Or
  • Difference between maximum and minimum temperature of ECT @ cylinder head < 1° C
  • Rationality check high:
  • Cross checks finished
  • Engine running
  • Engine off time >= 360.0 min
  • Valid AAT signal for time >= 2.0 s
  • Valid engine stop signal for time >= 2.0 s
  • Or
  • ECT @ cylinder head > -256° C
  • Modeled IAT @ throttle -48 - 143° C
  • Depending on thermostat control:
  • ECT @ cylinder head <= n.a. ° C
  • Or
  • ECT @ cylinder head >= n.a. ° C
  • Engine n.a.
  • And
  • Engine part load
  • Engine full load
  • Engine speed > 1, 300 RPM
  • Vehicle speed > 12 mph
  • Engine load > 2.0%
  • For time >= 20.0 - 43.0 s
  • Engine idle vehicle speed < 3 mph
  • Fuel cut off active
  • Or
  • Engine stop for time >= 20.0 - 43.0 s
  • Rationality check low:
  • Difference between modelled and measured cylinder head temperature > 5° C
  • ECT @ cylinder head -128 - 127° C
  • Time after engine start > 60.0 s
  • 30.0 s
  • Once / DCY
P0117 Engine Coolant Temperature Sensor 1 Circuit Low Input Engine Coolant Temperature Sensor @ Cylinder Head Short To Ground
  • ECT sensor voltage @ cylinder head < 0.30 V
 
  • 0.5 s
  • Continuous
  • 2 DCY
-- Check the Engine Coolant Temperature Sensor -G62-. Refer to Engine Coolant Temperature Sensor - G62-, CHECKING .
P0118 Engine Coolant Temperature Sensor 1 Circuit High Input Engine Coolant Temperature Sensor @ Cylinder Head Short To Battery / Open Circuit
  • ECT sensor voltage @ cylinder head > 4.90 V
  • Modeled IAT @ throttle >= -33° C
  • 0.5 s
  • Continuous
  • 2 DCY
-- Check the Engine Coolant Temperature Sensor -G62-. Refer to Engine Coolant Temperature Sensor - G62-, CHECKING .
P0121 Throttle/Pedal Position Sensor / Switch "A" Circuit Range / Performance Throttle Position Sensor 1 Rationality Check
  • Normalized difference between measured and modeled value of mass air flow from TPS 1 >= 1.0 [-]
  • Or
  • Relative mass air flow integral from TPS 1 > 60.0 [-]
  • Difference between TPS 1 and TPS 2 > 6.499° TPS
  • Throttle adaption not active
  • 0.01 s
  • Continuous
  • 2 DCY
-- Check the Throttle Valve Control Module -GX3-. Refer to Throttle Valve Control Module - GX3-, CHECKING .
P0122 Throttle / Pedal Position Sensor / Switch "A" Circuit Low Throttle Position Sensor 1 Short To Ground
  • Throttle position sensor 1 voltage < 0.15 V
 
  • 0.2 s
  • Continuous
  • 2 DCY
-- Check the Throttle Valve Control Module -GX3-. Refer to Throttle Valve Control Module - GX3-, CHECKING .
P0123 Throttle / Pedal Position Sensor / Switch "A" Circuit High Throttle Position Sensor 1 Short To Battery Voltage
  • Throttle position sensor 1 voltage > 4.85 V
 
  • 0.2 s
  • Continuous
  • 2 DCY
-- Check the Throttle Valve Control Module -GX3-. Refer to Throttle Valve Control Module - GX3-, CHECKING .
P0131 O2 Sensor Circuit, Bank 1 Sensor 1 Low Voltage Oxygen Sensors Front Short To Ground
  • O2S sensor voltage < 0.15 V
  • O2S heater front active
  • pump current controller active
  • measurement of WRAF sensor label resistor not active
  • active phase of open circuit diagnosis for linear lambda sensor not active
  • 0.5 s
  • Continuous
  • 2 DCY
-- Check the Oxygen Sensor 1 Before Catalytic Converter -GX10-. Refer to Oxygen Sensor 1 Before Catalytic Converter - GX10-, CHECKING .
P0132 O2 Sensor Circuit, Bank 1 Sensor 1 High Voltage Oxygen Sensors Front Short To Battery Voltage
  • O2S sensor voltage > 5.20 - 5.35 V
  • O2S heater front active
  • Pump current controller active
  • Measurement of WRAF sensor label resistor not active
  • Active phase of open circuit diagnosis for linear lambda sensor not active
  • 0.5 s
  • Continuous
  • 2 DCY
-- Check the Oxygen Sensor 1 Before Catalytic Converter -GX10-. Refer to Oxygen Sensor 1 Before Catalytic Converter - GX10-, CHECKING .
P0133  O2 Circuit Slow Response Bank 1, Sensor 1 Oxygen Sensors Front Response Check
  • Dynamic path:
  • Lambda value vs. modeled lambda value >= 1.25 [-]
  • Or
  • Ratio of failed diagnostic cycle > n.a. [-]
  • Or
  • Delay path:
  • Lambda delay value vs. modeled lambda value > 1.25 [-]
  • General conditions:
  • MAF >= 0.0 mg/stk
  • MAF <= 1, 389.0 mg/stk
  • Vehicle speed >= 0 mph
  • Time after engine start >= 0.0 s
  • Integrated mass for fuel in oil < 255.0 [-]
  • Engine speed 1, 216 - 3, 008 RPM
  • MAF (intake air rate) 25.0 - 150.0 kg/h
  • Vehicle speed >= 0 mph
  • ECT @ cylinder head >= -48° C
  • Integrated MAF after gear change > 0.0 g
  • Depending on transmission type:
  • For AT:
  • Integrated MAF per cylinder >= 0.50 - 2.0 kg
  • For DCT:
  • Integrated MAF per cylinder > 0.50 - 2.0 kg
  • For MT:
  • Integrated MAF per cylinder >= 0.50 - 2.0 kg
  • Depending on dynamic conditions:
  • Dynamic engine speed < 288 RPM
  • Dynamic torque < 80.0 Nm
  • Dynamic MAF < 70.0 kg/h
  • For time >= 0.6 s
  • And
  • Depending on canister and catalyst purge:
  • Evap purge n.a.
  • Or
  • Canister load calculation n.a
  • Or
  • Canister load <= n.a. [-]
  • 13.2 s
  • Once / DCY
  • 1 DCY
-- Check the Oxygen Sensor 1 Before Catalytic Converter -GX10-. Refer to Oxygen Sensor 1 Before Catalytic Converter - GX10-, CHECKING .
P0135  HO2S Heater Circuit Conditions Bank 1 Sensor 1 Oxygen Sensors Heater Front Functional Check
  • O2S ceramic temperature, < 630° C
  • Stir up O2S heater front (linear) finished
  • For time >= 10.0 s
  • 20.0 s
  • Continuous
  • 2 DCY
-- Check the Oxygen Sensor 1 Before Catalytic Converter -GX10-. Refer to Oxygen Sensor 1 Before Catalytic Converter - GX10-, CHECKING .
P0136 O2 Sensor Circuit Oxygen Sensors Rear Response Check
  • Gradient sensor voltage< 600.0 mV/s
  • General conditions:
  • Forced close the gap stimulation not active
  • Internal resistance O2S rear < 700.0 Ω
  • Close the gap stimulation request active
  • Vehicle speed >= 6 mph
  • Catalyst overheating protection not active
  • Turbine overheating protection not active
  • O2S rear ready
  • O2S front ready
  • ECT @ cylinder head > 60° C
  • Modeled catalyst temperature 470 - 780° C
  • Difference between dynamic and stationary catalyst temperature -306 - 304° C
  • Modeled catalyst temperature once after engine start > 550° C
  • Integrated MAF, catalyst temp. conditions fulfilled >= 0.0 g
  • Modeled EGT @ O2S rear <= 900° C
  • MAF per cylinder 30.0 - 200.0 kg/h
  • MAF per cylinder per stroke, lower range >= 89.99 mg/stk
  • MAF per cylinder per stroke, upper range <= 750.0 mg/stk
  • And
  • Low dynamic conditions deviation actual and target engine speed < 150 RPM
  • Dynamic MAF < 15.01 mg/stk
  • Dynamic lambda controller output <= 20.0%
  • And
  • Integrated MAF after dynamic conditions are fulfilled > 20.0 g
  • Time after a catalyst purge phase >= 1.0 s
  • O2S rear voltage @ diagnosis start >= 0.55 V
  • Integrated MAF to start diagnosis >= 5.0 g
  • Integrated heat energy >= 800.0 - 2, 000.0 kJ
  • Engine speed 1, 248 - 3, 008 RPM
  • Coasting function n.a
  • O2S heater rear active
  • Lambda adaptation not active
  • Valve lift n.a.
  • And
  • Depending on Lambda control:
  • Intervention of trim control behavior activation of catalyst diagnosis < 0.10 [-]
  • Or
  • Intervention of trim control during active catalyst diagnosis < 0.20 [-]
  • Depending on canister purge: canister load <= n.a. [-]
  • Evap purge flow n.a.
  • Or
  • Canister load calculation n.a.
  • Evap purge flow n.a.
  • Or
  • Evap purge valve n.a.
  • Depending on canister purge closing:
  • Canister purge (conditions) n.a.
  • Canister purge valve (closing time) n.a.
  • And
  • Choice of: evap purge valve n.a.
  • And
  • Modeled MAF-integral > 0.0 g
  • Depending on transmission type:
  • For MT:
  • Integrated MAF per cylinder >= 0.0 kg
  • For AT:
  • Integrated MAF per cylinder >= 0.0 kg
  • For DCT:
  • Integrated MAF per cylinder >= 0.0 kg
  • 60.0 - 70.0 s
  • Once / DCY
  • 1 DCY
-- Check the Oxygen Sensor 1 After Catalytic Converter -GX7-. Refer to Oxygen Sensor 1 After Catalytic Converter - GX7-, CHECKING .
P0137 HO2 Sensor Circuit Low Voltage Bank 1 Sensor 2 Oxygen Sensors Rear Short To Ground
  • O2S sensor voltage < 0.15 V
  • O2S heater active
  • 0.5 s
  • Continuous
  • 2 DCY
-- Check the Oxygen Sensor 1 After Catalytic Converter -GX7-. Refer to Oxygen Sensor 1 After Catalytic Converter - GX7-, CHECKING
P0138 HO2 Sensor Circuit High Voltage Bank 1 Sensor 2 Oxygen Sensors Rear Short To Battery
  • O2S sensor voltage > 5.2 - 5.35 V
  • O2S heater active
  • 0.5 s
  • Continuous
  • 2 DCY
-- Check the Oxygen Sensor 1 After Catalytic Converter -GX7-. Refer to Oxygen Sensor 1 After Catalytic Converter - GX7-, CHECKING
P013A  O2 Sensor Slow Response - Rich to Lean Bank 1 Sensor 2 Oxygen Sensors Rear Response Check
  • Gradient sensor voltage< 600.0 mV/s
  • General conditions:
  • Forced close the gap stimulation not active
  • Close the gap stimulation request active
  • Vehicle speed >= 6 mph
  • Catalyst overheating protection not active
  • Turbine overheating protection not active
  • O2S rear ready
  • O2S front ready
  • ECT @ cylinder head > 60° C
  • Modeled catalyst temperature 470 - 780° C
  • Difference between dynamic and stationary catalyst temperature -306 - 304° C
  • Modeled catalyst temperature once after engine start > 550° C
  • Integrated MAF, catalyst temp. conditions fulfilled >= 0.0 g
  • Modeled EGT @ O2S rear <= 900° C
  • MAF per cylinder 30.0 - 200.0 kg/h
  • MAF per cylinder per stroke, lower range >= 89.99 mg/stk
  • MAF per cylinder per stroke, upper range <= 750.0 mg/stk
  • And
  • Low dynamic conditions deviation actual
  • And
  • Target engine speed < 150 RPM
  • Dynamic MAF < 15.01 mg/stk
  • Dynamic lambda controller output <= 20.0%
  • And
  • Integrated MAF after dynamic conditions are fulfilled > 20.0 g
  • Time after a catalyst purge phase >= 1.0 s
  • O2S rear voltage @ diagnosis start >= 0.55 V
  • Integrated MAF to start diagnosis >= 5.0 g
  • Integrated heat energy >= 800.0 - 2, 000.0 kJ
  • Engine speed 1, 248 - 3, 008 RPM
  • Coasting function n.a. O2S
  • Heater rear active
  • Lambda adaptation not active
  • Valve lift n.a.
  • And
  • Depending on lambda control:
  • Intervention of trim control behavior activation of catalyst diagnosis < 0.10 [-]
  • Or
  • Intervention of trim control during active catalyst diagnosis < 0.20 [-]
  • Depending on canister purge:
  • Canister load <= n.a. [-]
  • Evap purge flow n.a.
  • Or
  • Canister load calculation n.a.
  • Evap purge flow n.a.
  • Or
  • Evap purge valve n.a
  • Depending on canister purge closing:
  • Canister purge (conditions) n.a.
  • Canister purge valve (closing time) n.a.
  • And
  • Choice of:
  • Evap purge valve n.a.
  • Or
  • Evap purge valve n.a.
  • And
  • Modeled MAF-integral > 0.0 g
  • Depending on transmission type:
  • For MT
  • Integrated MAF per cylinder >= 0.0 kg
  • For AT
  • Integrated MAF per cylinder >= 0.0 kg
  • For DCT
  • Integrated MAF per cylinder >= 0.0 kg
  • 60.0 - 70.0 s
  • Once / DCY
  • 2 DCY
-- Check the Oxygen Sensor 1 After Catalytic Converter -GX7-. Refer to Oxygen Sensor 1 After Catalytic Converter - GX7-, CHECKING .
P013B  O2 Sensor Slow Response - Lean to Rich Bank 1 Sensor 2 Oxygen Sensors Rear Response Check
  • Gradient sensor voltage< 600.0 mV/s
  • General conditions:
  • Forced close the gap stimulation not active
  • Internal resistance O2S rear < 700.0 Ω
  • Close the gap stimulation request active
  • Vehicle speed >= 6 mph
  • Catalyst overheating protection not active
  • Turbine overheating protection not active
  • O2S rear ready
  • O2S front ready
  • ECT @ cylinder head > 60° C
  • Modeled catalyst temperature 470 - 780° C
  • Difference between dynamic and stationary catalyst temperature -306 - 304° C
  • Modeled catalyst temperature once after engine start > 550° C
  • Integrated MAF, catalyst temp. conditions fulfilled >= 0.0 g
  • Modeled EGT @ O2S rear <= 900° C
  • MAF per cylinder 30.0 - 200.0 kg/h
  • MAF per cylinder per stroke, lower range >= 89.99 mg/stk
  • MAF per cylinder per stroke, upper range <= 750.0 mg/stk
  • And
  • Low dynamic conditions deviation actual and target engine speed < 150 RPM
  • Dynamic MAF < 15.01 mg/stk
  • Dynamic lambda controller output <= 20.0%
  • And
  • Integrated MAF after dynamic conditions are fulfilled > 20.0 g
  • Time after a catalyst purge phase >= 1.0 s
  • O2S rear voltage @ diagnosis start >= 0.55 V
  • Integrated MAF to start diagnosis >= 5.0 g
  • Integrated heat energy >= 800.0 - 2, 000.0 kJ
  • Engine speed 1, 248 - 3, 008 RPM
  • Coasting function n.a.
  • O2S heater rear active
  • Lambda adaptation not active
  • Valve lift n.a.
  • And
  • Depending on lambda control:
  • Intervention of trim control behavior activation of catalyst diagnosis < | 0.10 | [-]
  • Or
  • Intervention of trim control during active catalyst diagnosis < | 0.20 | [-]
  • Depending on canister purge: canister load <= n.a. [-]
  • Evap purge flow n.a.
  • Or
  • Canister load calculation n.a.
  • Evap purge flow n.a.
  • Or
  • Evap purge valve n.a.
  • Depending on canister purge closing:
  • Canister purge (conditions) n.a.
  • Canister purge valve (closing time) n.a.
  • And
  • Choice of: evap purge valve n.a.
  • And
  • Modeled MAF-integral > 0.0 g
  • Depending on transmission type:
  • For MT:
  • Integrated MAF per cylinder >= 0.0 kg
  • For AT:
  • Integrated MAF per cylinder >= 0.0 kg
  • For DCT:
  • Integrated MAF per cylinder >= 0.0 kg
  • 60.0 - 70.0 s
  • Once / DCY
  • 1 DCY
-- Check the Oxygen Sensor 1 After Catalytic Converter -GX7-. Refer to Oxygen Sensor 1 After Catalytic Converter - GX7-, CHECKING .
P013E  O2 Sensor Delayed Response - Rich to Lean Bank 1 Sensor 2 Oxygen Sensors Rear Delayed Response Monitoring, Delay Measurement
  • Sensor signal delay time > 1.0 s
  • General conditions:
  • Forced close the gap stimulation not active
  • Close the gap stimulation request active
  • Vehicle speed >= 6 mph
  • Catalyst overheating protection not active
  • Turbine overheating protection not active
  • O2S rear ready
  • O2S front ready
  • ECT @ cylinder head > 60° C
  • Modeled catalyst temperature 470 - 780° C
  • Difference between dynamic and stationary catalyst temperature -306 - 304° C
  • Modeled catalyst temperature once after engine start > 550° C
  • Integrated MAF, catalyst temp. conditions fulfilled >= 0.0 g
  • Modeled EGT @ O2S rear <= 900° C
  • MAF per cylinder 30.0 - 200.0 kg/h
  • MAF per cylinder per stroke, lower range >= 89.99 mg/stk
  • MAF per cylinder per stroke, upper range <= 750.0 mg/stk
  • And
  • Low dynamic conditions deviation actual
  • And
  • Target engine speed < 150 RPM
  • Dynamic MAF < 15.01 mg/stk
  • Dynamic lambda controller output <= 20.0%
  • And
  • Integrated MAF after dynamic conditions are fulfilled > 20.0 g
  • Time after a catalyst purge phase >= 1.0 s
  • O2S rear voltage @ diagnosis start >= 0.55 V
  • Integrated MAF to start diagnosis >= 5.0 g
  • Integrated heat energy >= 800.0 - 2, 000.0 kJ
  • Engine speed 1, 248 - 3, 008 RPM
  • Coasting function n.a. O2S
  • Heater rear active
  • Lambda adaptation not active
  • Valve lift n.a.
  • And
  • Depending on lambda control:
  • Intervention of trim control behavior activation of catalyst diagnosis < 0.10 [-]
  • Or
  • Intervention of trim control during active catalyst diagnosis < 0.20 [-]
  • Depending on canister purge:
  • Canister load <= n.a. [-]
  • Evap purge flow n.a.
  • Or
  • Canister load calculation n.a.
  • Evap purge flow n.a.
  • Or
  • Evap purge valve n.a
  • Depending on canister purge closing:
  • Canister purge (conditions) n.a.
  • Canister purge valve (closing time) n.a.
  • And
  • Choice of:
  • Evap purge valve n.a.
  • Or
  • Evap purge valve n.a.
  • And
  • Modeled MAF-integral > 0.0 g
  • Depending on transmission type:
  • For MT
  • Integrated MAF per cylinder >= 0.0 kg
  • For AT
  • Integrated MAF per cylinder >= 0.0 kg
  • For DCT
  • Integrated MAF per cylinder >= 0.0 kg
  • 60.0 - 70.0 s
  • Once / DCY
  • 1 DCY
-- Check the Oxygen Sensor 1 After Catalytic Converter -GX7-. Refer to Oxygen Sensor 1 After Catalytic Converter - GX7-, CHECKING
P013F  O2 Sensor Delayed Response - Lean to Rich Bank 1 Sensor 2 Oxygen Sensors Rear Delayed Response Monitoring, Delay Measurement
  • Sensor signal delay time > 1.5 s
  • General conditions:
  • Forced close the gap stimulation not active
  • Close the gap stimulation request active
  • Vehicle speed >= 6 mph
  • Catalyst overheating protection not active
  • Turbine overheating protection not active
  • O2S rear ready
  • O2S front ready
  • ECT @ cylinder head > 60° C
  • Modeled catalyst temperature 470 - 780° C
  • Difference between dynamic and stationary catalyst temperature -306 - 304° C
  • Modeled catalyst temperature once after engine start > 550° C
  • Integrated MAF, catalyst temp. conditions fulfilled >= 0.0 g
  • Modeled EGT @ O2S rear <= 900° C
  • MAF per cylinder 30.0 - 200.0 kg/h
  • MAF per cylinder per stroke, lower range >= 89.99 mg/stk
  • MAF per cylinder per stroke, upper range <= 750.0 mg/stk
  • And
  • Low dynamic conditions deviation actual
  • And
  • Target engine speed < 150 RPM
  • Dynamic MAF < 15.01 mg/stk
  • Dynamic lambda controller output <= 20.0%
  • And
  • Integrated MAF after dynamic conditions are fulfilled > 20.0 g
  • Time after a catalyst purge phase >= 1.0 s
  • O2S rear voltage @ diagnosis start >= 0.55 V
  • Integrated MAF to start diagnosis >= 5.0 g
  • Integrated heat energy >= 800.0 - 2, 000.0 kJ
  • Engine speed 1, 248 - 3, 008 RPM
  • Coasting function n.a. O2S
  • Heater rear active
  • Lambda adaptation not active
  • Valve lift n.a.
  • And
  • Depending on lambda control:
  • Intervention of trim control behavior activation of catalyst diagnosis < 0.10 [-]
  • Or
  • Intervention of trim control during active catalyst diagnosis < 0.20 [-]
  • Depending on canister purge:
  • Canister load <= n.a. [-]
  • Evap purge flow n.a.
  • Or
  • Canister load calculation n.a.
  • Evap purge flow n.a.
  • Or
  • Evap purge valve n.a
  • Depending on canister purge closing:
  • Canister purge (conditions) n.a.
  • Canister purge valve (closing time) n.a.
  • And
  • Choice of:
  • Evap purge valve n.a.
  • Or
  • Evap purge valve n.a.
  • And
  • Modeled MAF-integral > 0.0 g
  • Depending on transmission type:
  • For MT
  • Integrated MAF per cylinder >= 0.0 kg
  • For AT
  • Integrated MAF per cylinder >= 0.0 kg
  • For DCT
  • Integrated MAF per cylinder >= 0.0 kg
  • 60.0 - 70.0 s
  • Once / DCY
  • 1 DCY
-- Check the Oxygen Sensor 1 After Catalytic Converter -GX7-. Refer to Oxygen Sensor 1 After Catalytic Converter - GX7-, CHECKING .
P0140 HO2 Sensor Circuit No Activity Detected Bank 1 Sensor 2 Oxygen Sensors Rear Open Circuit
  • Internal resistance of O2S (binary) > 25, 000.0 Ω
 
  • 2.5 s
  • Continuous
  • 1 DCY
-- Check the Oxygen Sensor 1 After Catalytic Converter -GX7-. Refer to Oxygen Sensor 1 After Catalytic Converter - GX7-, CHECKING .
P0141  HO2 Sensor Heater Circuit Bank 1 Sensor 2 Oxygen Sensors Heater Rear Out Of Range High
  • Internal resistance of O2S (binary) 700.0 - 25, 000.0 Ω
  • Stir up O2S heater front (linear) finished
  • 20.0 s
  • Once / DCY
  • 1 DCY
-- Check the Oxygen Sensor 1 After Catalytic Converter -GX7-. Refer to Oxygen Sensor 1 After Catalytic Converter - GX7-, CHECKING .
P0171 Fuel System Lean Conditions Fuel System Too Lean
  • Lambda controller output > 35.0%
  • Lambda control closed loop
  • Barometric pressure > 73.0 kPa
  • Mass air flow > 60.0 mg/stk
  • Engine speed > 576 RPM
  • ECT @ cylinder head > 20° C
  • IAT at intake manifold > -48° C
  • AAT > -48° C
  • 60.0 s
  • Continuous
  • 2 DCY
-- Check the intake and vacuum hoses for leaks, Check the positive crankcase ventilation, and also make sure the oil dipstick is properly secured.-- Listen to and visually inspect the exhaust system to insure there are no leaks.-- Check the Oxygen Sensor 1 Before Catalytic Converter -GX10-. Refer to Oxygen Sensor 1 Before Catalytic Converter - GX10-, CHECKING .-- Check the Oxygen Sensor 1 After Catalytic Converter -GX7-. Refer to Oxygen Sensor 1 After Catalytic Converter - GX7-, CHECKING .
P0172 Fuel System Rich Conditions Fuel System Too Rich
  • Lambda controller output < -35.0%
  • Lambda control closed loop
  • Barometric pressure > 73.0 kPa
  • Mass air flow > 60.0 mg/stk
  • Engine speed > 576 RPM
  • ECT @ cylinder head > 20° C
  • IAT at intake manifold > -48° C
  • AAT > -48° C
  • Oil dilution not detected
  • 60.0 s
  • Continuous
  • 2 DCY
-- Check the Oxygen Sensor 1 Before Catalytic Converter -GX10-. Refer to Oxygen Sensor 1 Before Catalytic Converter - GX10-, CHECKING .-- Check the Oxygen Sensor 1 After Catalytic Converter -GX7-. Refer to Oxygen Sensor 1 After Catalytic Converter - GX7-, CHECKING .-- Check the Fuel Injectors --. Refer to Fuel Injectors --, CHECKING . -- Check the EVAP system for possible fuel contamination. Refer to appropriate repair information.
P0190 Fuel Rail Pressure Sensor "A" Circuit Fuel System Pressure Sensor, High Pressure Side Short To Battery / Open Circuit
  • High fuel pressure sensor voltage > 4.80 V
 
  • 2.0 [s]
  • continuous
  • 2 DCY
-- Check the Fuel Pressure Sensor -G247-. Refer to Fuel Pressure Sensor - G247-, CHECKING -- Check the fuel pressure, refer to the repair information for proper procedures.
P0191 Fuel Rail Pressure Sensor "A" Circuit Range/Performance Fuel Rail, High Pressure Side Out Of Range
  • Fuel pressure > 29, 300.0 kPa
  • Engine running
  • Engine speed < 6, 816 RPM
  • Time after engine start > 10.0 s
  • 5.0 s
  • Continuous
  • 2 DCY
-- Check the Fuel Pressure Sensor -G247-. Refer to Fuel Pressure Sensor - G247-, CHECKING -- Check the fuel pressure, refer to the repair information for proper procedures.
P0192 Fuel Rail Pressure Sensor "A" Circuit Low Fuel System Pressure Sensor, High Pressure Side Short To Ground
  • High fuel pressure sensor voltage < 0.20 V
 
  • 2.0 s
  • Continuous
  • 2 DCY
-- Check the Fuel Pressure Sensor -G247-. Refer to Fuel Pressure Sensor - G247-, CHECKING -- Check the fuel pressure, refer to the repair information for proper procedures.
P0201 Injector Circuit Open Cylinder 1 Injector Values Electrical Error, Open Or Short Circuit
  • Indeterminate fault pattern via power stage diagnosis detected and injector low side voltage < 2.0 V
  • Injector low side switch current > 25.0 A
  • Or
  • Injector low side voltage < 2.0 V
  • Injector high side switch current > 25.0 A
  • Or
  • Injector low side voltage (hardware values) < 2.0 V
  • Injector low side switch current (hardware values) > 9.0 - 14.0 A
  • Or
  • Injector voltage < 2.0 V
  • Injector low side switch current > 25.0 A
  • Or
  • Injector voltage (hardware values) < 2.0 V
  • Injector low side switch current (hardware values) > 9.0 - 14.0 A
  • Or
  • Injector load resistance to ground and battery > 20.0 Ω
  • Injector low side switch current > 25.0 A
  • Or
  • Injector load resistance to ground and battery > 20.0 Ω
  • Injector high side switch current > 25.0 A
  • Or
  • Power stage temperature > 150° C
  • Or
  • Fault pattern for short circuit via powerstage diagnosis detected
  • Injector current rise time during peak phase < 0.064 ms
  • Engine stop not active
  • ECT @ cylinder head >= -30° C
  • Engine speed < 7, 000 RPM
  • Injection time >= 0.0 s
  • 8, 640.0° CRK
  • Continuous
  • 2 DCY
-- Check the Fuel Injectors --. Refer to Fuel Injectors --, CHECKING .
P0202 Injector Circuit Open Cylinder 2 Injector Values Electrical Error, Open Or Short Circuit
  • Indeterminate fault pattern via power stage diagnosis detected and injector low side voltage < 2.0 V
  • Injector low side switch current > 25.0 A
  • Or
  • Injector low side voltage < 2.0 V
  • Injector high side switch current > 25.0 A
  • Or
  • Injector low side voltage (hardware values) < 2.0 V
  • Injector low side switch current (hardware values) > 9.0 - 14.0 A
  • Or
  • Injector voltage < 2.0 V
  • Injector low side switch current > 25.0 A
  • Or
  • Injector voltage (hardware values) < 2.0 V
  • Injector low side switch current (hardware values) > 9.0 - 14.0 A
  • Or
  • Injector load resistance to ground and battery > 20.0 Ω
  • Injector low side switch current > 25.0 A
  • Or
  • Injector load resistance to ground and battery > 20.0 Ω
  • Injector high side switch current > 25.0 A
  • Or
  • Power stage temperature > 150° C
  • Or
  • Fault pattern for short circuit via powerstage diagnosis detected
  • Injector current rise time during peak phase < 0.064 ms
  • Engine stop not active
  • ECT @ cylinder head >= -30° C
  • Engine speed < 7, 000 RPM
  • Injection time >= 0.0 s
  • 8, 640.0° CRK
  • Continuous
  • 2 DCY
-- Check the Fuel Injectors --. Refer to Fuel Injectors --, CHECKING .
P0203 Injector Circuit Open Cylinder 3 Injector Values Electrical Error, Open Or Short Circuit
  • Indeterminate fault pattern via power stage diagnosis detected and injector low side voltage < 2.0 V
  • Injector low side switch current > 25.0 A
  • Or
  • Injector low side voltage < 2.0 V
  • Injector high side switch current > 25.0 A
  • Or
  • Injector low side voltage (hardware values) < 2.0 V
  • Injector low side switch current (hardware values) > 9.0 - 14.0 A
  • Or
  • Injector voltage < 2.0 V
  • Injector low side switch current > 25.0 A
  • Or
  • Injector voltage (hardware values) < 2.0 V
  • Injector low side switch current (hardware values) > 9.0 - 14.0 A
  • Or
  • Injector load resistance to ground and battery > 20.0 Ω
  • Injector low side switch current > 25.0 A
  • Or
  • Injector load resistance to ground and battery > 20.0 Ω
  • Injector high side switch current > 25.0 A
  • Or
  • Power stage temperature > 150° C
  • Or
  • Fault pattern for short circuit via powerstage diagnosis detected
  • Injector current rise time during peak phase < 0.064 ms
  • Engine stop not active
  • ECT @ cylinder head >= -30° C
  • Engine speed < 7, 000 RPM
  • Injection time >= 0.0 s
  • 8, 640.0° CRK
  • Continuous
  • 2 DCY
-- Check the Fuel Injectors --. Refer to Fuel Injectors --, CHECKING .
P0204 Injector Circuit Open Cylinder 4 Injector Values Electrical Error, Open Or Short Circuit
  • Indeterminate fault pattern via power stage diagnosis detected and injector low side voltage < 2.0 V
  • Injector low side switch current > 25.0 A
  • Or
  • Injector low side voltage < 2.0 V
  • Injector high side switch current > 25.0 A
  • Or
  • Injector low side voltage (hardware values) < 2.0 V
  • Injector low side switch current (hardware values) > 9.0 - 14.0 A
  • Or
  • Injector voltage < 2.0 V
  • Injector low side switch current > 25.0 A
  • Or
  • Injector voltage (hardware values) < 2.0 V
  • Injector low side switch current (hardware values) > 9.0 - 14.0 A
  • Or
  • Injector load resistance to ground and battery > 20.0 Ω
  • Injector low side switch current > 25.0 A
  • Or
  • Injector load resistance to ground and battery > 20.0 Ω
  • Injector high side switch current > 25.0 A
  • Or
  • Power stage temperature > 150° C
  • Or
  • Fault pattern for short circuit via powerstage diagnosis detected
  • Injector current rise time during peak phase < 0.064 ms
  • Engine stop not active
  • ECT @ cylinder head >= -30° C
  • Engine speed < 7, 000 RPM
  • Injection time >= 0.0 s
  • 8, 640.0° CRK
  • Continuous
  • 2 DCY
-- Check the Fuel Injectors --. Refer to Fuel Injectors --, CHECKING .
P0221 Throttle / Pedal Position Sensor / Switch "B" Circuit Range / Performance Throttle Position Sensor 2 Rationality Check
  • Normalized difference between measured and modeled value of mass air flow from TPS 2 >= 1.0 [-]
  • Throttle adaption not active
  • 0.01 s
  • Continuous
  • 2 DCY
-- Check the Throttle Valve Control Module -GX3-. Refer to Throttle Valve Control Module - GX3-, CHECKING .
P0222 Throttle / Pedal Position Sensor / Switch "B" Circuit Low Throttle Position Sensor 2 Short To Ground
  • Throttle position sensor 2 voltage < 0.15 V
 
  • 0.2 s
  • Continuous
  • 2 DCY
-- Check the Throttle Valve Control Module -GX3-. Refer to Throttle Valve Control Module - GX3-, CHECKING .
P0223 Throttle / Pedal Position Sensor / Switch "B" Circuit High Throttle Position Sensor 2 Short To Battery Voltage
  • Throttle position sensor 2 voltage > 4.85 V
 
  • 0.2 s
  • Continuous
  • 2 DCY
-- Check the Throttle Valve Control Module -GX3-. Refer to Throttle Valve Control Module - GX3-, CHECKING .
P0236 Turbocharger Boost Sensor Circuit Range / Performance Turbocharger Boost Pressure Sensor Rationality Check
  • By engine standing three sensors:
  • Diff. barometric pressure vs. upstream throttle pressure >= 8.50 kPa
  • Or
  • Diff. upstream throttle pressure vs. intake manifold pressure >= 8.50 kPa
  • By full load: diff.
  • Upstream throttle pressure vs. intake manifold pressure > 10.0 kPa
  • During ECM keep alive-time:
  • Diff. upstream throttle pressure vs. intake manifold pressure >= 8.50 kPa
  • Diff. intake manifold pressure vs. intake manifold pressure @ idle or low part load >= n.a. kPa
  • Or
  • Diff. barometric pressure vs. upstream throttle pressure >= 8.50 kPa
  • Diff. upstream throttle pressure @ full or high part load vs. upstream throttle pressure < n.a. kPa
  • Case 1:
  • Engine stop active vehicle speed < 1 mph
  • Delay after engine stop >= 5.0 s
  • For time >= 10.0 s
  • Case 2:
  • Engine stop active
  • Vehicle speed < 1 mph
  • Delay after engine stop >= 5.0 s
  • Engine speed > 2, 000 RPM
  • Engine running
  • Throttle position > 20.999 - 78.003° TPS
  • For time >= 2.0 s
  • Engine stop active
  • Ignition off
  • Vehicle speed < 1 mph
  • Delay time in ECM keep alive-time > 10.0 s
  • Delay after engine stop >= 5.0 s
  • Barometric pressure sensor voltage 0.20 - 4.80 V
  • Intake manifold pressure sensor voltage 0.20 - 4.80 V
  • Turbocharger boost pressure sensor voltage 0.20 - 4.80 V
  • 2.0 s
  • Continuous
  • 2 DCY
-- Check the Charge Air Pressure Sensor -G31-. Refer to Charge Air Pressure Sensor - G31-, CHECKING .
P0237 Turbocharger/Supercharger Boost Sensor "A" Circuit Low Turbocharger Boost Pressure Sensor Short To Ground
  • Turbocharger boost pressure sensor voltage < 0.20 V
 
  • 0.5 s
  • Continuous
  • 2 DCY
-- Check the Charge Air Pressure Sensor -G31-. Refer to Charge Air Pressure Sensor - G31-, CHECKING
P0238 Turbocharger/Supercharger Boost Sensor "A" Circuit High Turbocharger Boost Pressure Sensor Short To Battery Voltage
  • Turbocharger boost pressure sensor voltage > 4.80 V
 
  • 0.5 s
  • Continuous
  • 2 DCY
-- Check the Charge Air Pressure Sensor -G31-. Refer to Charge Air Pressure Sensor - G31-, CHECKING
P025A Fuel Pump Module Control Circuit Open Fuel Pump Open Circuit
  • Signal voltage, lower range > 1.92 - 2.21 V
  • And
  • Signal voltage, upper range (hardware values) < 2.84 - 3.25 V
  • Commanded PWM 9.80 - 90.20.0%
  • Fuel pump commanded off
  • 0.5 s
  • Continuous
  • 2 DCY
-- Check the Fuel Delivery Unit -GX1- / Fuel Pump Control Module -J538-. Refer to Fuel Delivery Unit -GX1- / Fuel Pump Control Module -J538-, CHECKING .
P025C Fuel Pump Module Control Circuit Low Fuel Pump Short To Ground
  • Signal voltage (hardware values) < 1.92 - 2.21 V
  • Commanded PWM 9.80 - 90.20.0%
  • Fuel pump commanded off
  • 0.5 s
  • Continuous
  • 2 DCY
-- Check the Fuel Delivery Unit -GX1- / Fuel Pump Control Module -J538-. Refer to Fuel Delivery Unit -GX1- / Fuel Pump Control Module -J538-, CHECKING .
P025D Fuel Pump Module Control Circuit High Fuel Pump Short To Battery Voltage
  • Power stage temperature > 160.0 - 200.0° C
  • Or
  • Signal current (hardware values)> 0.1 - 0.18 A
  • Commanded PWM 9.80 - 90.20%
  • Fuel pump commanded on
  • 0.5 s
  • Continuous
  • 2 DCY
-- Check the Fuel Delivery Unit -GX1- / Fuel Pump Control Module -J538-. Refer to Fuel Delivery Unit -GX1- / Fuel Pump Control Module -J538-, CHECKING .
P0261 Cylinder 1 Injector Circuit Low Injector Values Short To Ground
  • Fault pattern for short to ground via powerstage diagnosis detected
  • Injector voltage < 2.0 V
  • And
  • Injector driver high side switch current < 25.0 A
  • Or
  • Injector driver low side switch current (hardware values) < 25.0 A
  • Engine stop not active
  • ECT @ cylinder head >= -30° C
  • Engine speed < 7, 000 RPM
  • Injection time >= 0.0 s
  • 8, 640.0° CRK
  • Continuous
  • 2 DCY
  • Actual TPS 2 calculated value > TPS 1 calculated value
-- Check the Fuel Injectors --. Refer to Fuel Injectors --, CHECKING .
P0262 Cylinder 1 Injector Circuit High Injector Values Short To Battery Voltage
  • Fault pattern for short to Battery voltage via powerstage diagnosis detected
  • Injector voltage > 2.0 V
  • And
  • Injector driver high side switch current > 25.0 A
  • Or
  • Injector driver low side switch current (hardware values) > 25.0 A
  • Engine stop not active
  • ECT @ cylinder head >= -30° C
  • Engine speed < 7, 000 RPM
  • Injection time >= 0.0 s
  • 8, 640.0° CRK
  • Continuous
  • 2 DCY
  • Actual TPS 2 calculated value > TPS 1 calculated value
-- Check the Fuel Injectors --. Refer to Fuel Injectors --, CHECKING .
P0264 Cylinder 2 Injector Circuit Low Injector Values Short To Ground
  • Fault pattern for short to ground via powerstage diagnosis detected
  • Injector voltage < 2.0 V
  • And
  • Injector driver high side switch current < 25.0 A
  • Or
  • Injector driver low side switch current (hardware values) < 25.0 A
  • Engine stop not active
  • ECT @ cylinder head >= -30° C
  • Engine speed < 7, 000 RPM
  • Injection time >= 0.0 s
  • 8, 640.0° CRK
  • Continuous
  • 2 DCY
  • Actual TPS 2 calculated value > TPS 1 calculated value
-- Check the Fuel Injectors --. Refer to Fuel Injectors --, CHECKING .
P0265 Cylinder 2 Injector Circuit High Injector Values Short To Battery Voltage
  • Fault pattern for short to Battery voltage via powerstage diagnosis detected
  • Injector voltage > 2.0 V
  • And
  • Injector driver high side switch current > 25.0 A
  • Or
  • Injector driver low side switch current (hardware values) > 25.0 A
  • Engine stop not active
  • ECT @ cylinder head >= -30° C
  • Engine speed < 7, 000 RPM
  • Injection time >= 0.0 s
  • 8, 640.0° CRK
  • Continuous
  • 2 DCY
  • Actual TPS 2 calculated value > TPS 1 calculated value
-- Check the Fuel Injectors --. Refer to Fuel Injectors --, CHECKING .
P0267 Cylinder 3 Injector Circuit Low Injector Values Short To Ground
  • Fault pattern for short to ground via powerstage diagnosis detected
  • Injector voltage < 2.0 V
  • And
  • Injector driver high side switch current < 25.0 A
  • Or
  • Injector driver low side switch current (hardware values) < 25.0 A
  • Engine stop not active
  • ECT @ cylinder head >= -30° C
  • Engine speed < 7, 000 RPM
  • Injection time >= 0.0 s
  • 8, 640.0° CRK
  • Continuous
  • 2 DCY
  • Actual TPS 2 calculated value > TPS 1 calculated value
-- Check the Fuel Injectors --. Refer to Fuel Injectors --, CHECKING .
P0268 Cylinder 3 Injector Circuit High Injector Values Short To Battery Voltage
  • Fault pattern for short to Battery voltage via powerstage diagnosis detected
  • Injector voltage > 2.0 V
  • And
  • Injector driver high side switch current > 25.0 A
  • Or
  • Injector driver low side switch current (hardware values) > 25.0 A
  • Engine stop not active
  • ECT @ cylinder head >= -30° C
  • Engine speed < 7, 000 RPM
  • Injection time >= 0.0 s
  • 8, 640.0° CRK
  • Continuous
  • 2 DCY
  • Actual TPS 2 calculated value > TPS 1 calculated value
-- Check the Fuel Injectors --. Refer to Fuel Injectors --, CHECKING .
P0270 Cylinder 4 Injector Circuit Low Injector Values Short To Ground
  • Fault pattern for short to ground via powerstage diagnosis detected
  • Injector voltage < 2.0 V
  • And
  • Injector driver high side switch current < 25.0 A
  • Or
  • Injector driver low side switch current (hardware values) < 25.0 A
  • Engine stop not active
  • ECT @ cylinder head >= -30° C
  • Engine speed < 7, 000 RPM
  • Injection time >= 0.0 s
  • 8, 640.0° CRK
  • Continuous
  • 2 DCY
  • Actual TPS 2 calculated value > TPS 1 calculated value
-- Check the Fuel Injectors --. Refer to Fuel Injectors --, CHECKING .
P0271 Cylinder 4 Injector Circuit High Injector Values Short To Battery Voltage
  • Fault pattern for short to Battery voltage via powerstage diagnosis detected
  • Injector voltage > 2.0 V
  • And
  • Injector driver high side switch current > 25.0 A
  • Or
  • Injector driver low side switch current (hardware values) > 25.0 A
  • Engine stop not active
  • ECT @ cylinder head >= -30° C
  • Engine speed < 7, 000 RPM
  • Injection time >= 0.0 s
  • 8, 640.0° CRK
  • Continuous
  • 2 DCY
  • Actual TPS 2 calculated value > TPS 1 calculated value
-- Check the Fuel Injectors --. Refer to Fuel Injectors --, CHECKING .
P0300 Random Misfire Detected Crankshaft Speed Fluctuation (Multiple)
  • Number of cylinders with emission threshold misfire within 4, 000 revolutions ≥ 2.0 [-]
  • Or
  • Number of cylinders with emission threshold misfire within 1, 000 revolutions ≥ 2.0 [-]
  • Emission threshold misfire detected
  • 0.0 s
  • Continuous
  • 2 DCY
-- Check the spark plugs visually for signs of fouling.-- Check the intake system visually for leaks (false air).-- Check for an engine mechanical fault with a cylinder compression test. Carbon buildup may cause a higher than normal compression reading and may contribute to this concern. Refer to appropriate repair information for low compression readings or for carbon buildup removal.-- Check the Fuel Injectors --. Refer to Fuel Injectors --, CHECKING .-- Check the Ignition Coils with Power Output Stage --. Refer to Ignition Coils with Power Output Stage --, CHECKING .
  • Number of cylinders with catalyst damaging misfire ≥ 2.0 [-]
  • Catalyst damaging misfire detected
  • Immediate
P0301  Cylinder 1 Misfire Detected Crankshaft Speed Fluctuation (Single Or Multiple)
  • Catalyst damage misfire For AT:
  • Catalyst damaging misfire rate > 1.8 - 20.3%
  • For DCT:
  • Catalyst damaging misfire rate > 1.8 - 20.3%
  • For MT:
  • Catalyst damaging misfire rate > 1.8 - 20.3%
  • Emission threshold misfire within 1, 000 rev
  • For AT:
  • Emission threshold misfire rate (MR) > 2.3%
  • For DCT:
  • Emission threshold misfire rate (MR) > 2.3%
  • For MT:
  • Emission threshold misfire rate (MR) > 2.3%
  • Emission threshold misfire within 4, 000 rev
  • For AT:
  • Emission threshold misfire rate (MR) > 2.3%
  • For DCT:
  • Emission threshold misfire rate (MR) > 2.3%
  • For MT:
  • Emission threshold misfire rate (MR) > 2.3%
  • Initial engine speed > 550 RPM
  • Engine speed > 550 RPM
  • Engine speed < 6, 848 RPM
  • Barometric pressure >= 60.01 kPa
  • Time after engine start > 0.0 s
  • And
  • Depending on transmission mode
  • For MT:
  • Engine load > 5.05 - 47.0%
  • For AT:
  • Engine load > 4.68 - 41.67%
  • For DCT:
  • Engine load > 4.18 - 36.0%
  • And
  • Depending on ECT @ cylinder head @ start
  • ECT @ cylinder head @ start <= -48° C
  • ECT @ cylinder head >= 20° C
  • Or
  • ECT @ cylinder head @ engine start > -48° C
  • And
  • Fuel cut off not active
  • Or
  • Single fuel cut off not active
  • Or
  • Number of fade out cylinders < 2.0 [-]
  • And
  • Dynamic manifold air pressure <= n.a. kPa
  • Dynamic throttle position <= n.a. ° TPS/s
  • And
  • Engine n.a.
  • Engine speed < n.a. RPM
  • Dynamic of ignition angle <= n.a. ° CRK
  • Or
  • Dynamic of ignition angle <= n.a. ° CRK
  • And
  • Rough road not detected
  • 0.1 s
  • Once / DCY
  • 2 DCY
-- Check the spark plugs visually for signs of fouling.-- Check the intake system visually for leaks (false air).-- Check for an engine mechanical fault with a cylinder compression test. Carbon buildup may cause a higher than normal compression reading and may contribute to this concern. Refer to appropriate repair information for low compression readings or for carbon buildup removal.-- Check the Fuel Injectors --. Refer to Fuel Injectors --, CHECKING .-- Check the Ignition Coils with Power Output Stage --. Refer to Ignition Coils with Power Output Stage --, CHECKING .
P0302  Cylinder 2 Misfire Detected Crankshaft Speed Fluctuation (Single Or Multiple)
  • Catalyst damage misfire For AT:
  • Catalyst damaging misfire rate > 1.8 - 20.3%
  • For DCT:
  • Catalyst damaging misfire rate > 1.8 - 20.3%
  • For MT:
  • Catalyst damaging misfire rate > 1.8 - 20.3%
  • Emission threshold misfire within 1, 000 rev
  • For AT:
  • Emission threshold misfire rate (MR) > 2.3%
  • For DCT:
  • Emission threshold misfire rate (MR) > 2.3%
  • For MT:
  • Emission threshold misfire rate (MR) > 2.3%
  • Emission threshold misfire within 4, 000 rev
  • For AT:
  • Emission threshold misfire rate (MR) > 2.3%
  • For DCT:
  • Emission threshold misfire rate (MR) > 2.3%
  • For MT:
  • Emission threshold misfire rate (MR) > 2.3%
  • Initial engine speed > 550 RPM
  • Engine speed > 550 RPM
  • Engine speed < 6, 848 RPM
  • Barometric pressure >= 60.01 kPa
  • Time after engine start > 0.0 s
  • And
  • Depending on transmission mode
  • For MT:
  • Engine load > 5.05 - 47.0%
  • For AT:
  • Engine load > 4.68 - 41.67%
  • For DCT:
  • Engine load > 4.18 - 36.0%
  • And
  • Depending on ECT @ cylinder head @ start
  • ECT @ cylinder head @ start <= -48° C
  • ECT @ cylinder head >= 20° C
  • Or
  • ECT @ cylinder head @ engine start > -48° C
  • And
  • Fuel cut off not active
  • Or
  • Single fuel cut off not active
  • Or
  • Number of fade out cylinders < 2.0 [-]
  • And
  • Dynamic manifold air pressure <= n.a. kPa
  • Dynamic throttle position <= n.a. ° TPS/s
  • And
  • Engine n.a.
  • Engine speed < n.a. RPM
  • Dynamic of ignition angle <= n.a. ° CRK
  • Or
  • Dynamic of ignition angle <= n.a. ° CRK
  • And
  • Rough road not detected
  • 0.1 s
  • Once / DCY
  • 2 DCY
-- Check the spark plugs visually for signs of fouling.-- Check the intake system visually for leaks (false air).-- Check for an engine mechanical fault with a cylinder compression test. Carbon buildup may cause a higher than normal compression reading and may contribute to this concern. Refer to appropriate repair information for low compression readings or for carbon buildup removal.-- Check the Fuel Injectors --. Refer to Fuel Injectors --, CHECKING .-- Check the Ignition Coils with Power Output Stage --. Refer to Ignition Coils with Power Output Stage --, CHECKING .
P0303  Cylinder 3 Misfire Detected Crankshaft Speed Fluctuation (Single Or Multiple)
  • Catalyst damage misfire For AT:
  • Catalyst damaging misfire rate > 1.8 - 20.3%
  • For DCT:
  • Catalyst damaging misfire rate > 1.8 - 20.3%
  • For MT:
  • Catalyst damaging misfire rate > 1.8 - 20.3%
  • Emission threshold misfire within 1, 000 rev
  • For AT:
  • Emission threshold misfire rate (MR) > 2.3%
  • For DCT:
  • Emission threshold misfire rate (MR) > 2.3%
  • For MT:
  • Emission threshold misfire rate (MR) > 2.3%
  • Emission threshold misfire within 4, 000 rev
  • For AT:
  • Emission threshold misfire rate (MR) > 2.3%
  • For DCT:
  • Emission threshold misfire rate (MR) > 2.3%
  • For MT:
  • Emission threshold misfire rate (MR) > 2.3%
  • Initial engine speed > 550 RPM
  • Engine speed > 550 RPM
  • Engine speed < 6, 848 RPM
  • Barometric pressure >= 60.01 kPa
  • Time after engine start > 0.0 s
  • And
  • Depending on transmission mode
  • For MT:
  • Engine load > 5.05 - 47.0%
  • For AT:
  • Engine load > 4.68 - 41.67%
  • For DCT:
  • Engine load > 4.18 - 36.0%
  • And
  • Depending on ECT @ cylinder head @ start
  • ECT @ cylinder head @ start <= -48° C
  • ECT @ cylinder head >= 20° C
  • Or
  • ECT @ cylinder head @ engine start > -48° C
  • And
  • Fuel cut off not active
  • Or
  • Single fuel cut off not active
  • Or
  • Number of fade out cylinders < 2.0 [-]
  • And
  • Dynamic manifold air pressure <= n.a. kPa
  • Dynamic throttle position <= n.a. ° TPS/s
  • And
  • Engine n.a.
  • Engine speed < n.a. RPM
  • Dynamic of ignition angle <= n.a. ° CRK
  • Or
  • Dynamic of ignition angle <= n.a. ° CRK
  • And
  • Rough road not detected
  • 0.1 s
  • Once / DCY
  • 2 DCY
-- Check the spark plugs visually for signs of fouling.-- Check the intake system visually for leaks (false air).-- Check for an engine mechanical fault with a cylinder compression test. Carbon buildup may cause a higher than normal compression reading and may contribute to this concern. Refer to appropriate repair information for low compression readings or for carbon buildup removal.-- Check the Fuel Injectors --. Refer to Fuel Injectors --, CHECKING .-- Check the Ignition Coils with Power Output Stage --. Refer to Ignition Coils with Power Output Stage --, CHECKING .
P0304  Cylinder 4 Misfire Detected Crankshaft Speed Fluctuation (Single Or Multiple)
  • Catalyst damage misfire For AT:
  • Catalyst damaging misfire rate > 1.8 - 20.3%
  • For DCT:
  • Catalyst damaging misfire rate > 1.8 - 20.3%
  • For MT:
  • Catalyst damaging misfire rate > 1.8 - 20.3%
  • Emission threshold misfire within 1, 000 rev
  • For AT:
  • Emission threshold misfire rate (MR) > 2.3%
  • For DCT:
  • Emission threshold misfire rate (MR) > 2.3%
  • For MT:
  • Emission threshold misfire rate (MR) > 2.3%
  • Emission threshold misfire within 4, 000 rev
  • For AT:
  • Emission threshold misfire rate (MR) > 2.3%
  • For DCT:
  • Emission threshold misfire rate (MR) > 2.3%
  • For MT:
  • Emission threshold misfire rate (MR) > 2.3%
  • Initial engine speed > 550 RPM
  • Engine speed > 550 RPM
  • Engine speed < 6, 848 RPM
  • Barometric pressure >= 60.01 kPa
  • Time after engine start > 0.0 s
  • And
  • Depending on transmission mode
  • For MT:
  • Engine load > 5.05 - 47.0%
  • For AT:
  • Engine load > 4.68 - 41.67%
  • For DCT:
  • Engine load > 4.18 - 36.0%
  • And
  • Depending on ECT @ cylinder head @ start
  • ECT @ cylinder head @ start <= -48° C
  • ECT @ cylinder head >= 20° C
  • Or
  • ECT @ cylinder head @ engine start > -48° C
  • And
  • Fuel cut off not active
  • Or
  • Single fuel cut off not active
  • Or
  • Number of fade out cylinders < 2.0 [-]
  • And
  • Dynamic manifold air pressure <= n.a. kPa
  • Dynamic throttle position <= n.a. ° TPS/s
  • And
  • Engine n.a.
  • Engine speed < n.a. RPM
  • Dynamic of ignition angle <= n.a. ° CRK
  • Or
  • Dynamic of ignition angle <= n.a. ° CRK
  • And
  • Rough road not detected
  • 0.1 s
  • Once / DCY
  • 2 DCY
-- Check the spark plugs visually for signs of fouling.-- Check the intake system visually for leaks (false air).-- Check for an engine mechanical fault with a cylinder compression test. Carbon buildup may cause a higher than normal compression reading and may contribute to this concern. Refer to appropriate repair information for low compression readings or for carbon buildup removal.-- Check the Fuel Injectors --. Refer to Fuel Injectors --, CHECKING .-- Check the Ignition Coils with Power Output Stage --. Refer to Ignition Coils with Power Output Stage --, CHECKING .
P0326 Knock Sensor 1 Circuit Range / Performance Knock Sensor Out Of Range
  • Sensor signal < 0.12 - 0.31 V
  • ECT @ cylinder head > 60° C
  • MAF > 229.0 mg/stk
  • Engine speed > 2, 016 RPM
  • 4.0 s
  • Continuous
  • 2 DCY
-- Check the Knock Sensor 1 -G61-. Refer to Knock Sensor 1 - G61-, CHECKING .
P0327 Knock Sensor 1 Circuit Low Knock Sensor Rationality Check Low
  • Difference between knock sensor signal and average knock sensor signal < 0.0 - 0.12 V
  • ECT @ cylinder head > 60° C
  • MAF > 229.0 mg/stk
  • 4.3 s
  • Continuous
  • 2 DCY
-- Check the Knock Sensor 1 -G61-. Refer to Knock Sensor 1 - G61-, CHECKING .
P0335 Crankshaft Position Sensor "A" Circuit RPM Sensor Activity Check
  • Case 1:
  • Counted exhaust camshaft signals without synchronization >= 1.0 [-]
  • Or
  • Counted intake camshaft signals without synchronization >= n.a. [-]
  • Case 2:
  • Counted exhaust camshaft signals without synchronization >= 1.0 [-]
  • Or
  • Counted intake camshaft signals without synchronization >= 17.0 [-]
  • Signal edges @ selected camshaft signal detected
  • Choice of:
  • Ignition off
  • Engine speed > 380 RPM
  • Engine stalling >= 1.0 s
  • Or
  • Synchronization test incorrect
  • Or
  • Engine speed >= 380 RPM
  • Or
  • Engine running engine stalling >= 5.0 s
  • Or
  • Backwards rotation not detected
  • Or
  • Engine speed >= 300 RPM
  • Engine stop active
  • 0.01 s
  • Continuous
  • 2 DCY
-- Check the Engine Speed Sensor -G28-. Refer to Engine Speed Sensor - G28-, CHECKING .
P0336 Crankshaft Position Sensor "A" Circuit Range/Performance RPM Sensor Out Of Range
  • Segment adaptation >= 0.70%
  • Fuel cut off all cylinders
  • Segment adaptation active
  • Difference between one segment time < 100 μs
  • Cylinder shut off not active
  • For MT:
  • Engine speed 2, 016 - 5, 024 RPM
  • For AT:
  • Engine speed 2, 016 - 5, 024 RPM
  • For DCT:
  • Engine speed 2, 016 - 5, 024 RPM
  • 900.0° CRK
  • Continuous
  • 2 DCY
-- Check the Engine Speed Sensor -G28-. Refer to Engine Speed Sensor - G28-, CHECKING .
  • Counted teeth vs reference >= 1.0; <= 2.0 [-]
  • Cylinder shut off not active
  • Engine running
  • 3, 600.0° CRK
  • Continuous
Crankshaft Position Sensor Rationality Check
  • Case 1:
  • Engine speed > 1, 200 RPM
  • Time between falling signal edges < 50 - 832 μs
  • Case 2:
  • Engine speed <= 1, 200 RPM
  • Time between signal edges < 30 μs
  • Engine speed >= 380 RPM
  • 4, 5720.0° CRK
  • Continuous
Crankshaft Position Sensor Rationality Check
  • Crankshaft reference gap not detected
  • General conditions:
  • Start/Stop reference gap detected
  • And
  • Case 1:
  • Ignition off
  • Engine speed > 380 RPM
  • Engine stalling >= 1.0 s
  • Or
  • Case 2:
  • Engine speed >= 380 RPM
  • Or
  • Engine running
  • And
  • Engine stalling >= 5.0 s
  • Or
  • Case 3:
  • Backwards rotation not detected
  • Or
  • Case 4:
  • Engine speed >= 300 RPM
  • Engine stopped
  • 2, 160° CRK
  • Continuous
Crankshaft Position Sensor Rationality Check
  • Counted teeth vs. reference >= 1.0; <= 2.0 [-]
  • General conditions:
  • Engine speed > 320 RPM
  • And
  • Case 1:
  • Ignition off
  • Engine speed > 380 RPM
  • Engine stalling >= 1.0 s
  • Or
  • Case 2:
  • Engine speed >= 380 RPM
  • Or
  • Engine running
  • And
  • Engine stalling >= 5.0 s
  • Or
  • Case 3:
  • Backwards rotation not detected
  • Or
  • Case 4:
  • Engine speed >= 300 RPM
  • Engine stopped
  • 1, 800° CRK
  • Continuous
P0340 Camshaft Position Sensor "A" Circuit Camshaft Position Sensor Circuit
  • No change on signal >= 3.0 [-]
  • Engine speed >= 380 RPM
  • 4, 680.0° CRK
  • Continuous
  • 2 DCY
-- Check the Camshaft Position Sensor -G40-. Refer to Camshaft Position Sensor - G40-, CHECKING .
P0341 Camshaft Position Sensor "A" Circuit Range / Performance Camshaft Position Sensor Intake: Rationality Check
  • Ratio between measured segment time ratio and specified camshaft angle ratio > 2.75 [-]
  • Or
  • ratio between measured segment time ratio and specified camshaft angle ratio < 0.36 [-]
  • Or
  • Offset between camshaft and crankshaft < -79.0° CRK
  • Or
  • Offset between camshaft and crankshaft > 15.0° CRK
 
  • 990.0° CRK
  • Continuous
  • 2 DCY
-- Check the Camshaft Position Sensor -G40-. Refer to Camshaft Position Sensor - G40-, CHECKING .
Signal Activity Check
  • Segment time value < 50 μs
  • Engine speed 380 - 8, 160 RPM
  • 1, 440.0° CRK
  • Continuous
Angular Offset Check
  • Offset between camshaft and crankshaft < -79.0; > 15.0° CRK
  • Engine speed > 32 RPM
  • 450.0° CRK
  • Once / DCY
P0351 Ignition Coil "A" Primary / Secondary Circuit Ignition Coil Open Circuit
  • Output voltage in OFF state, lower range (hardware values) >= 1.92 - 2.21 V
  • Output voltage in OFF state, upper range (hardware values) <= 2.85 - 3.25 V
  • Engine speed > 512 RPM
  • ECT @ cylinder head > -30° C
  • Engine stop not active
  • 1.0 s
  • Continuous
  • 2 DCY
-- Check the Ignition Coils with Power Output Stage --. Refer to Ignition Coils with Power Output Stage --, CHECKING .
Short To Ground
  • Output current in ON state (hardware values) > 50.0 - 100.0 mA
Short To Battery Voltage
  • Diagnosis_by_inactive_low side:
  • Switch in ATIC: output voltage in OFF state (hardware values) > 4.95 - 5.285 V
  • Or
  • Diagnosis_by_inactive_low side:
  • Switch in ATIC: output temperature from ATIC in ON state > 160.0 - 200.0° C
  • Or
  • Output current in ON state (hardware values) > 100.0 - 180.0 mA
  • Engine speed > 512 RPM
  • Engine stop not active
  • Actuator commanded off
  • Or
  • Engine speed > 512 RPM
  • Engine stop not active
  • Actuator commanded on
P0352 Ignition Coil "B" Primary / Secondary Circuit Ignition Coil Open Circuit
  • Output voltage in OFF state, lower range (hardware values) >= 1.92 - 2.21 V
  • Output voltage in OFF state, upper range (hardware values) <= 2.85 - 3.25 V
  • Engine speed > 512 RPM
  • ECT @ cylinder head > -30° C
  • Engine stop not active
  • 1.0 s
  • Continuous
  • 2 DCY
-- Check the Ignition Coils with Power Output Stage --. Refer to Ignition Coils with Power Output Stage --, CHECKING .
Short To Ground
  • Output current in ON state (hardware values) > 50.0 - 100.0 mA
Short To Battery Voltage
  • Diagnosis_by_inactive_low side:
  • Switch in ATIC: output voltage in OFF state (hardware values) > 4.95 - 5.285 V
  • Or
  • Diagnosis_by_inactive_low side:
  • Switch in ATIC: output temperature from ATIC in ON state > 160.0 - 200.0° C
  • Or
  • Output current in ON state (hardware values) > 100.0 - 180.0 mA
  • Engine speed > 512 RPM
  • Engine stop not active
  • Actuator commanded off
  • Or
  • Engine speed > 512 RPM
  • Engine stop not active
  • Actuator commanded on
P0353 Ignition Coil "C" Primary / Secondary Circuit Ignition Coil Open Circuit
  • Output voltage in OFF state, lower range (hardware values) >= 1.92 - 2.21 V
  • Output voltage in OFF state, upper range (hardware values) <= 2.85 - 3.25 V
  • Engine speed > 512 RPM
  • ECT @ cylinder head > -30° C
  • Engine stop not active
  • 1.0 s
  • Continuous
  • 2 DCY
-- Check the Ignition Coils with Power Output Stage --. Refer to Ignition Coils with Power Output Stage --, CHECKING .
Short To Ground
  • Output current in ON state (hardware values) > 50.0 - 100.0 mA
Short To Battery Voltage
  • Diagnosis_by_inactive_low side:
  • Switch in ATIC: output voltage in OFF state (hardware values) > 4.95 - 5.285 V
  • Or
  • Diagnosis_by_inactive_low side:
  • Switch in ATIC: output temperature from ATIC in ON state > 160.0 - 200.0° C
  • Or
  • Output current in ON state (hardware values) > 100.0 - 180.0 mA
  • Engine speed > 512 RPM
  • Engine stop not active
  • Actuator commanded off
  • Or
  • Engine speed > 512 RPM
  • Engine stop not active
  • Actuator commanded on
P0354 Ignition Coil "D" Primary / Secondary Circuit Ignition Coil Open Circuit
  • Output voltage in OFF state, lower range (hardware values) >= 1.92 - 2.21 V
  • Output voltage in OFF state, upper range (hardware values) <= 2.85 - 3.25 V
  • Engine speed > 512 RPM
  • ECT @ cylinder head > -30° C
  • Engine stop not active
  • 1.0 s
  • Continuous
  • 2 DCY
-- Check the Ignition Coils with Power Output Stage --. Refer to Ignition Coils with Power Output Stage --, CHECKING .
Short To Ground
  • Output current in ON state (hardware values) > 50.0 - 100.0 mA
Short To Battery Voltage
  • Diagnosis_by_inactive_low side:
  • Switch in ATIC: output voltage in OFF state (hardware values) > 4.95 - 5.285 V
  • Or
  • Diagnosis_by_inactive_low side:
  • Switch in ATIC: output temperature from ATIC in ON state > 160.0 - 200.0° C
  • Or
  • Output current in ON state (hardware values) > 100.0 - 180.0 mA
  • Engine speed > 512 RPM
  • Engine stop not active
  • Actuator commanded off
  • Or
  • Engine speed > 512 RPM
  • Engine stop not active
  • Actuator commanded on
P0366 Camshaft Position Sensor "B" Circuit Range / Performance Camshaft Position Sensor Exhaust Rationality Check
  • Ratio between measured segment time ratio and specified camshaft angle ratio > 2.75 [-]
  • Or
  • Ratio between measured segment time ratio and specified camshaft angle ratio < 0.36 [-]
  • Or
  • Offset between camshaft and crankshaft < -24.0° CRK
  • Or
  • Offset between camshaft and crankshaft > 49.0° CRK
  • Engine speed 380 - 8, 160 RPM
  • 990.0° CRK
  • Continuous
  • 2 DCY
-- Check the Camshaft Position Sensor 3 -G300-. Refer to Camshaft Position Sensor 3 - G300-, CHECKING .
Signal Activity Check
  • Segment time value < 50 μs
  • 1, 440.0° CRK
  • Continuous
Out Of Range
  • Offset between camshaft and crankshaft < -24.00° CRK
  • Or
  • Offset between camshaft and crankshaft > 49.0° CRK
  • Engine synchronization not validated
  • 450.0° CRK
  • Once / DCY
P039B Cylinder 1 Pressure Too High Knock Control Function Check Cyl. 1
  • Slow detection:
  • Ratio between knock sensor and knock threshold in main knock window > 2.0 - 3.0 [-]
  • For time >= 4, 500.0 - 7.200.0° CRK
  • Or
  • Ratio between knock sensor and noise level in pre knock window > 3.5 - 5.0 [-]
  • For time >= 2, 160.0 - 3, 240.0° CRK
  • Or
  • Ratio between knock sensor and noise level in pre knock window > 3.5 - 5.0 [-]
  • Ratio between knock sensor and knock threshold in main knock window > 2.0 - 3.0 [-]
  • For time >= 5, 760.0 - 9, 540.0° CRK
  • Or
  • Torque limitation factor < 0.90 [-]
  • Engine running ECT @ cylinder head > 60° C
  • Engine speed 1, 216 - 6, 400 RPM
  • Engine load n.a. %
  • Mass air flow > 403.0 - 447.0 mg/stk
  • Dynamic engine speed not active
  • 900.0° CRK
  • Continuous
  • 2 DCY
-- Check the Knock Sensor 1 -G61-. Refer to Knock Sensor 1 - G61-, CHECKING .
  • Fast detection:
  • Ratio between knock sensor and knock threshold in main knock window > 1.50 - 2.50 [-]
  • For time >= 540.0° CRK
  • Or
  • Ratio between knock sensor and noise level in pre knock window > 2.75 - 4.50 [-]
  • For time >= 360.0° CRK
  • Case 1:
  • Ratio between filtered engine roughness and misfire detection threshold <= 0.41 - 0.59 [-]
  • Or
  • Case 2:
  • Ratio between normalized engine roughness and misfire detection threshold <= n.a. [-]
  • Or
  • Case 3:
  • Ratio between filtered engine roughness and misfire detection threshold <= n.a. [-]
  • Or
  • Ratio between normalized engine roughness and misfire detection threshold <= n.a. [-]
P03A5 Cylinder 2 Pressure Too High Knock Control Function Check Cyl. 2
  • Slow detection:
  • Ratio between knock sensor and knock threshold in main knock window > 2.0 - 3.0 [-]
  • For time >= 4, 500.0 - 7.200.0° CRK
  • Or
  • Ratio between knock sensor and noise level in pre knock window > 3.5 - 5.0 [-]
  • For time >= 2, 160.0 - 3, 240.0° CRK
  • Or
  • Ratio between knock sensor and noise level in pre knock window > 3.5 - 5.0 [-]
  • Ratio between knock sensor and knock threshold in main knock window > 2.0 - 3.0 [-]
  • For time >= 5, 760.0 - 9, 540.0° CRK
  • Or
  • Torque limitation factor < 0.90 [-]
  • Engine running ECT @ cylinder head > 60° C
  • Engine speed 1, 216 - 6, 400 RPM
  • Engine load n.a. %
  • Mass air flow > 403.0 - 447.0 mg/stk
  • Dynamic engine speed not active
  • 900.0° CRK
  • Continuous
  • 2 DCY
-- Check the Knock Sensor 1 -G61-. Refer to Knock Sensor 1 - G61-, CHECKING .
  • Fast detection:
  • Ratio between knock sensor and knock threshold in main knock window > 1.50 - 2.50 [-]
  • For time >= 540.0° CRK
  • Or
  • Ratio between knock sensor and noise level in pre knock window > 2.75 - 4.50 [-]
  • For time >= 360.0° CRK
  • Case 1:
  • Ratio between filtered engine roughness and misfire detection threshold <= 0.41 - 0.59 [-]
  • Or
  • Case 2:
  • Ratio between normalized engine roughness and misfire detection threshold <= n.a. [-]
  • Or
  • Case 3:
  • Ratio between filtered engine roughness and misfire detection threshold <= n.a. [-]
  • Or
  • Ratio between normalized engine roughness and misfire detection threshold <= n.a. [-]
P03AF Cylinder 3 Pressure Too High Knock Control Function Check Cyl. 3
  • Slow detection:
  • Ratio between knock sensor and knock threshold in main knock window > 2.0 - 3.0 [-]
  • For time >= 4, 500.0 - 7.200.0° CRK
  • Or
  • Ratio between knock sensor and noise level in pre knock window > 3.5 - 5.0 [-]
  • For time >= 2, 160.0 - 3, 240.0° CRK
  • Or
  • Ratio between knock sensor and noise level in pre knock window > 3.5 - 5.0 [-]
  • Ratio between knock sensor and knock threshold in main knock window > 2.0 - 3.0 [-]
  • For time >= 5, 760.0 - 9, 540.0° CRK
  • Or
  • Torque limitation factor < 0.90 [-]
  • Engine running ECT @ cylinder head > 60° C
  • Engine speed 1, 216 - 6, 400 RPM
  • Engine load n.a. %
  • Mass air flow > 403.0 - 447.0 mg/stk
  • Dynamic engine speed not active
  • 900.0° CRK
  • Continuous
  • 2 DCY
-- Check the Knock Sensor 1 -G61-. Refer to Knock Sensor 1 - G61-, CHECKING .
  • Fast detection:
  • Ratio between knock sensor and knock threshold in main knock window > 1.50 - 2.50 [-]
  • For time >= 540.0° CRK
  • Or
  • Ratio between knock sensor and noise level in pre knock window > 2.75 - 4.50 [-]
  • For time >= 360.0° CRK
  • Case 1:
  • Ratio between filtered engine roughness and misfire detection threshold <= 0.41 - 0.59 [-]
  • Or
  • Case 2:
  • Ratio between normalized engine roughness and misfire detection threshold <= n.a. [-]
  • Or
  • Case 3:
  • Ratio between filtered engine roughness and misfire detection threshold <= n.a. [-]
  • Or
  • Ratio between normalized engine roughness and misfire detection threshold <= n.a. [-]
P03B9 Cylinder 4 Pressure Too High Knock Control Function Check Cyl. 4
  • Slow detection:
  • Ratio between knock sensor and knock threshold in main knock window > 2.0 - 3.0 [-]
  • For time >= 4, 500.0 - 7.200.0° CRK
  • Or
  • Ratio between knock sensor and noise level in pre knock window > 3.5 - 5.0 [-]
  • For time >= 2, 160.0 - 3, 240.0° CRK
  • Or
  • Ratio between knock sensor and noise level in pre knock window > 3.5 - 5.0 [-]
  • Ratio between knock sensor and knock threshold in main knock window > 2.0 - 3.0 [-]
  • For time >= 5, 760.0 - 9, 540.0° CRK
  • Or
  • Torque limitation factor < 0.90 [-]
  • Engine running ECT @ cylinder head > 60° C
  • Engine speed 1, 216 - 6, 400 RPM
  • Engine load n.a. %
  • Mass air flow > 403.0 - 447.0 mg/stk
  • Dynamic engine speed not active
  • 900.0° CRK
  • Continuous
  • 2 DCY
-- Check the Knock Sensor 1 -G61-. Refer to Knock Sensor 1 - G61-, CHECKING .
  • Fast detection:
  • Ratio between knock sensor and knock threshold in main knock window > 1.50 - 2.50 [-]
  • For time >= 540.0° CRK
  • Or
  • Ratio between knock sensor and noise level in pre knock window > 2.75 - 4.50 [-]
  • For time >= 360.0° CRK
  • Case 1:
  • Ratio between filtered engine roughness and misfire detection threshold <= 0.41 - 0.59 [-]
  • Or
  • Case 2:
  • Ratio between normalized engine roughness and misfire detection threshold <= n.a. [-]
  • Or
  • Case 3:
  • Ratio between filtered engine roughness and misfire detection threshold <= n.a. [-]
  • Or
  • Ratio between normalized engine roughness and misfire detection threshold <= n.a. [-]
P0410  Secondary Air Injection System Secondary Air System Functional Check
  • Diff. pressure value after secondary air injection vs. pressure value before secondary air activation > 5.0 kPa
  • General:
  • Secondary air pump ready
  • Catalyst heating active
  • Secondary air injection finished
  • MAF <= 140.0 kg/h
  • ECT @ cylinder head >= -10; < 115° C
  • IAT @ manifold >= -10; < 100° C
  • Modeled catalyst temperature < 700° C
  • Relative barometric pressure > 0.73 [-]
  • Diff. barometric pressure vs. manifold pressure > n.a. kPa
  • 0.1 s
  • Once / DCY
  • 2 DCY
-- Check the Secondary Air Injection Pump Relay -J299- / Secondary Air Injection Pump Motor -V101-. Refer to Secondary Air Injection Pump Relay - J299- / Secondary Air Injection Pump Motor - V101-, CHECKING .-- Check the Secondary Air Injection Sensor 1 -G609-. Refer to Secondary Air Injection Sensor 1 - G609-, CHECKING .-- Check the Secondary Air Injection Solenoid Valve -N112-. Refer to Secondary Air Injection Solenoid Valve - N112-, CHECKING .
P0413 Secondary Air Injection System Switching Valve "A" Circuit Open Secondary Air Valve Open Circuit
  • Output voltage, lower range >= 1.92 - 2.21 V
  • Output voltage, upper range (hardware values) <= 2.85 - 3.25 V
  • Engine running
  • Actuator commanded off
  • 1.0 s
  • Continuous
  • 2 DCY
-- Check the Secondary Air Injection Solenoid Valve -N112-. Refer to Secondary Air Injection Solenoid Valve - N112-, CHECKING .
P0414 Secondary Air Injection System Switching Valve "A" Circuit Shorted Secondary Air Valve Shorted
  • Output voltage (hardware values) < 1.92 - 2.21 V
  • Engine running
  • Actuator commanded off
  • 1.0 s
  • Continuous
  • 2 DCY
-- Check the Secondary Air Injection Solenoid Valve -N112-. Refer to Secondary Air Injection Solenoid Valve - N112-, CHECKING .
  • Actuator temperature > 160 - 200° C
  • Or
  • Output current (hardware values) > 1.0 - 2.0 A
  • Engine running
  • Actuator commanded on
P0418 Secondary Air Injection System Control "A" Circuit Secondary Air Injection Pump Relay Open Circuit
  • Output voltage, lower range 1.92 - 2.21 V
  • Output voltage, upper range (hardware values) <= 2.85 - 3.25 V
  • Engine running
  • Actuator commanded off
  • 1.0 s
  • Continuous
  • 2 DCY
-- Check the Secondary Air Injection Pump Relay -J299- / Secondary Air Injection Pump Motor -V101-. Refer to Secondary Air Injection Pump Relay - J299- / Secondary Air Injection Pump Motor - V101-, CHECKING .
P0420  Catalyst System Efficiency NMOG / NMHC Conversion Capability
  • Catalyst efficiency > 1.0 [-]
  • General conditions:
  • Vehicle speed >= 6 mph
  • Catalyst overheating protection not active
  • Turbine overheating protection not active
  • O2S rear ready
  • O2S front ready
  • ECT @ cylinder head > 60° C
  • Modeled catalyst temperature 470 - 780° C
  • Difference between dynamic and stationary catalyst temperature -306 - 304° C
  • Modeled catalyst temperature once after engine start > 550° C
  • Integrated MAF, catalyst temp. conditions fulfilled >= 0.0 g
  • Modeled EGT @ O2S rear <= 900° C
  • MAF per cylinder 30.0 - 200.0 kg/h
  • MAF per cylinder per stroke, lower range >= 89.99 mg/stk
  • MAF per cylinder per stroke, upper range <= 750.0 mg/stk
  • And
  • Low dynamic conditions deviation actual and target engine speed < 150 RPM
  • Dynamic MAF < 15.01 mg/stk
  • Lambda controller output <= 20.0%
  • Dynamic and integrated MAF after dynamic conditions are fulfilled > 20.0 g
  • Time after a catalyst purge phase >= 1.0 s
  • O2S rear voltage @ diagnosis start >= 0.55 V
  • Integrated MAF to start diagnosis >= 5.0 g
  • Integrated heat energy >= 800.0 - 2, 000.0 kJ
  • Engine speed 1, 248 - 3, 008 RPM
  • Coasting function n.a.
  • O2S heater rear active
  • Lambda adaptation not active
  • Valve lift n.a.
  • Depending on Lambda control:
  • Intervention of trim control behavior activation of catalyst diagnosis < 0.10 [-]
  • Or
  • Intervention of trim control during active catalyst diagnosis < 0.20 [-]
  • Choice of: canister load <= n.a. [-]
  • Evap purge n.a
  • Or
  • Canister load calculation n.a.
  • Evap purge n.a.
  • Or
  • Evap purge valve n.a.
  • Or
  • Evap purge n.a.
  • Or
  • Canister purge (conditions) n.a.
  • Canister purge valve (closing time) n.a.
  • And
  • Choice of:
  • Evap purge valve n.a.
  • Or
  • Evap purge n.a.
  • And
  • Modeled MAF-integral > 0.0 g
  • Depending on transmission type:
  • For MT integrated MAF per cylinder >= 0.0 kg
  • For AT integrated MAF per cylinder >= 0.0 kg
  • For DCT integrated MAF per cylinder >= 0.0 kg
  • 60.0 - 70.0 s
  • Once / DCY
  • 1 DCY
-- Check the Oxygen Sensor 1 After Catalytic Converter -GX7-. Refer to Oxygen Sensor 1 After Catalytic Converter - GX7-, CHECKING .
P0441  Evaporative Emission System Incorrect Purge Flow EVAP Purge ValveFunctional Check: Stuck Close
  • Ratio actual intake manifold pressure and modeled set point intake manifold pressure < 0.10 [-]
  • ECT @ cylinder head > 58° C
  • Barometric pressure > 73.0 kPa
  • AAT > 4.50° C
  • AAT @ start < 4.50° C
  • Diff. barometric pressure vs. filtered intake manifold pressure n.a.
  • Diff. barometric pressure vs. filtered intake manifold pressure > 25.0 kPa
  • Ratio MAF @ intake manifold and MAF max. > 0.07 - 0.09[-]
  • Engine speed 1, 180 - 2, 700 RPM
  • Vehicle speed >= 11mph
  • Diff. engine speed vs. filtered engine speed< 90 RPM
  • Diff. ratio MAF @ intake manifold and MAF max vs. ratio filtered MAF @ intake manifold and MAF max< 0.15 [-]
  • Diff. modeled intake manifold pressure vs. filtered modeled intake manifold pressure < 1.50 kPa
  • And
  • Integrated MAF since engine start >= 0.0 - 5, 000.0 g
  • Lambda control active
  • Lambda control value -30.0 - 30.0%
  • O2S front 0.95 - 1.05 [-]
  • Case 1:
  • Integrated MAF @ canister purge per driving cycle >= n.a.g
  • Case 2:
  • Integrated MAF @ canister purge valve >= 2.1 g
  • Ratio MAF @ canister purge and MAF per cylinder>= 0.0 [-]
  • And
  • Depending on AAT:
  • AAT>= 50° C
  • Canister load <= 0.25 [-]
  • Or
  • AAT>= 30; < 50° C
  • Canister load <= 0.25 [-]
  • Or
  • AAT < 30° C
  • Canister load <= 0.25 [-]
  • 8.5 s
  • Once / DCY
  • 2 DCY
-- Check the EVAP Canister Purge Regulator Valve 1 -N80-. Refer to EVAP Canister Purge Regulator Valve 1 - N80-, CHECKING .
P0444 Evaporative Emission System Purge Control Valve Circuit Open EVAP Purge Valve Open Circuit
  • Output voltage, lower range >= 1.92 - 2.21 V
  • Output voltage, upper range (hardware values) <= 2.85 - 3.25 V
  • Engine start not active
  • Engine running
  • Evap purge valve opening signal (PWM) 3.13 - 98.83%
  • Actuator commanded off
  • 2.0 s
  • Continuous
  • 2 DCY
-- Check the EVAP Canister Purge Regulator Valve 1 -N80-. Refer to EVAP Canister Purge Regulator Valve 1 - N80-, CHECKING .
P0445 Evaporative Emission System Purge Control Valve Circuit Shorted EVAP Purge Valve Short To Ground Or Short To Battery Voltage
  • Output voltage 1.92 - 2.21 V (hardware values)
  • Engine start not active
  • Engine running
  • Evap purge valve opening signal (PWM) <= 98.83%
  • Actuator commanded off
  • 2.0 s
  • Continuous
  • 2 DCY
-- Check the EVAP Canister Purge Regulator Valve 1 -N80-. Refer to EVAP Canister Purge Regulator Valve 1 - N80-, CHECKING .
P0450 Evaporative Emission System Pressure Sensor/Switch NVLD Switch Open Circuit
  • Signal voltage 0.39 - 0.55 V
  • Case 1:
  • Engine running
  • Case 2:
  • Ignition off
  • NVLD (EVAP-System) diagnostic mode active
  • 0.5 s
  • Continuous
  • 2 DCY
-- Check the Fuel Tank Leak Detection Control Module -J909-. Refer to Fuel Tank Leak Detection Control Module - J909-, CHECKING .
P0451 Evaporative Emission System Pressure Sensor/Switch Range/Performance NVLD Switch Functional Check Stuck Close
  • NVLD switch position closed
  • Ignition off
  • Fuel level < 85.10%
  • Fuel temperature increase >= 5 K
  • For time >= 1.0 h
  • AAT >= 4° C
  • Barometric pressure >= 73.0 kPa
  • Time since ignition off > 20.0; < 1, 440.0 min
  • 0.1 s
  • Once / DCY
  • 2 DCY
-- Check the Fuel Tank Leak Detection Control Module -J909-. Refer to Fuel Tank Leak Detection Control Module - J909-, CHECKING .
P0452 Evaporative Emission System Pressure Sensor/Switch Low NVLD Switch Short To Battery Plus
  • Signal voltage > 3.0 V
  • Case 1:
  • Engine running
  • Case 2:
  • Ignition off
  • NVLD (EVAP-System) diagnostic mode active
  • 0.5 s
  • Continuous
  • 2 DCY
-- Check the Fuel Tank Leak Detection Control Module -J909-. Refer to Fuel Tank Leak Detection Control Module - J909-, CHECKING .
P0453 Evaporative Emission System Pressure Sensor/Switch High NVLD Switch Short To Ground
  • Signal voltage < 0.24 V
  • Case 1:
  • Engine running
  • Case 2:
  • Ignition off
  • NVLD (EVAP-System) diagnostic mode active
  • 0.5 s
  • Continuous
  • 2 DCY
-- Check the Fuel Tank Leak Detection Control Module -J909-. Refer to Fuel Tank Leak Detection Control Module - J909-, CHECKING .
P0456  Evaporative Emission System Leak Detected Very Small Leak EVAP System Small Leak Functional Check
  • Natural vacuum leak detection (NVLD) switch position = Open
  • Ignition off
  • Fuel level < 85.10%
  • Fuel temperature drop >= 6 K
  • For time > 1.0 h
  • AAT >= 4° C
  • Barometric pressure > 73.0 kPa
  • Diff. barometric pressure @ stop and barometric pressure @ start < 0.65 kPa
  • Time since ignition off > 90.0 min; < 600.0 min
  • 0.1 s
  • Once / DCY
  • 2 DCY
-- Check the EVAP System for any leaking hoses or damage to components. -- Check the EVAP Canister Purge Regulator Valve 1 -N80-. Refer to EVAP Canister Purge Regulator Valve 1 - N80-, CHECKING .-- Check the Fuel Tank Leak Detection Control Module -J909-. Refer to Fuel Tank Leak Detection Control Module - J909-, CHECKING .
P0461 Fuel Level Sensor "A" Circuit Range / Performance Fuel Level Plausibility Check
  • Diff. fuel consumption
  • And
  • Fuel level changes < -12.0; > 12.0 l
  • General:
  • Vehicle speed > 19 mph
  • And
  • Case 1:
  • For tank full fuel level > 96.09%
  • Fuel consumption since last refueling or last plausibility check > 30.0 l
  • Case 2:
  • For tank not full fuel level <= 96.09%
  • Fuel consumption since last refueling or last plausibility check > 15.0 l
  • 1.0 s
  • Multiple
  • 2 DCY
  • Check the Fuel Level Sensor -G-. Refer to appropriate repair information.
P0462 Fuel Level Sensor "A" Circuit Low CAN: Fuel Level Sensor 1 CAN Communication With Instrument Cluster Module
  • Instrument cluster module signal: short to ground failure
  • Instrument cluster module signal: signal range check failure
 
  • 0.5 s
  • Continuous
  • 2 DCY
  • Check the Fuel Level Sensor -G-. Refer to appropriate repair information.
P0463 Fuel Level Sensor "A" Circuit High CAN: Fuel Level Sensor 1 CAN Communication With Instrument Cluster Module
  • Instrument cluster module signal: short to battery / open circuit failure
 
  • 0.5 s
  • Continuous
  • 2 DCY
  • Check the Fuel Level Sensor -G-. Refer to appropriate repair information.
P0491  Secondary Air Injection System Insufficient Flow Secondary Air System Functional Check
  • Case 1:
  • Blockage: ratio relative measured secondary air pressure and modelled secondary air pressure [tube blocked] < 0.70 [-]
  • Or
  • Leakage: ratio relative measured secondary air pressure and modelled secondary air pressure [leak diagnosis] < 0.60 [-]
  • Case 2:
  • Diff. expected integrated secondary air pressure pulsations and actual integrated secondary air pressure pulsations n.a. kPa
  • Case 3:
  • Blockage: ratio relative measured secondary air pressure and modelled secondary air pressure [tube blocked] < 0.15 [-]
  • Or
  • Leakage: ratio relative measured secondary air pressure and modelled secondary air pressure [leak diagnosis] < 0.15 [-]
  • General:
  • Secondary air pump active
  • Catalyst heating active
  • Secondary air injection active
  • MAF <= 140.0 kg/h
  • ECT @ cylinder head >= -10; < 115° C
  • IAT @ manifold >= -10; < 100° C
  • Modelled catalyst temperature < 700° C
  • Relative barometric pressure > 0.73 [-]
  • Diff. barometric pressure vs. manifold pressure > n.a. kPa
  • 0.1 s
  • Once / DCY
  • 2 DCY
-- Check the secondary air combination valve visually. Replace if necessary. Refer to appropriate repair information.-- Check the Secondary Air Injection Pump Relay -J299- / Secondary Air Injection Pump Motor -V101-. Refer to Secondary Air Injection Pump Relay - J299- / Secondary Air Injection Pump Motor - V101-, CHECKING .-- Check the Secondary Air Injection Solenoid Valve -N112-. Refer to Secondary Air Injection Solenoid Valve - N112-, CHECKING .
P0501 Vehicle Speed Sensor "A" Range / Performance CAN: Vehicle Speed Sensor CAN Communication With Vehicle Speed Sensor
  • Speed sensor fault value:
  • Out of range high failure
  • Or
  • Out of range low failure
  • Or
  • Rationality check high failure
  • Or
  • Rationality check low failure
 
  • 1.3 s
  • Continuous
  • 2 DCY
-- Check the vehicle speed signal. Refer to VEHICLE SPEED SIGNAL, CHECKING .
P0502 Vehicle Speed Sensor "A" Circuit Low Vehicle Speed Electrical Check
  • Vehicle speed sensor signal: electrical error
 
  • 1.3 s
  • Continuous
  • 2 DCY
-- Check the vehicle speed signal. Refer to VEHICLE SPEED SIGNAL, CHECKING .
P0506 Idle Air Control System RPM Lower Than Expected Idle Controller Function Monitoring: Out Of Range Low
  • Negative engine speed deviation from set point > 100 RPM
  • Integrated I-part of idle speed controller n.a.
  • Gear switch not active
  • Vehicle speed = 0 mph
  • For time >= 0.0 s
  • Driver request not active
  • Throttle actuator commanded on
  • Evap purge flow < 4.0 kg/h
  • Torque safety limitation not active
  • Clutch switch n.a.
  • Barometric pressure > 69.99 kPa
  • Catalyst heating not active
  • ECT @ cylinder head > -48° C
  • Time after engine start > 0.0 s
  • Set point change n.a.
  • For time n.a.
  • 12.0 s
  • Continuous
  • 2 DCY
-- Check the Throttle Valve Control Module -GX3-. Refer to Throttle Valve Control Module - GX3-, CHECKING .
P0507 Idle Air Control System RPM Higher Than Expected Idle Controller Function Monitoring: Out Of Range High
  • Positive engine speed deviation from set point > 90 RPM
  • Integrated I-part of idle speed controller n.a.
  • Gear switch not active
  • Vehicle speed = 0 mph
  • For time >= 0.0 s
  • Driver request not active
  • Throttle actuator commanded on
  • Evap purge flow < 4.0 kg/h
  • Torque safety limitation not active
  • Clutch switch n.a.
  • Barometric pressure > 69.99 kPa
  • Catalyst heating not active
  • ECT @ cylinder head > -48° C
  • Time after engine start > 0.0 s
  • Set point change n.a.
  • For time n.a.
  • 12.0 s
  • Continuous
  • 2 DCY
-- Check the Throttle Valve Control Module -GX3-. Refer to Throttle Valve Control Module - GX3-, CHECKING .
P050A Cold Start Idle Air Control System Performance Cold Idle Controller Function Monitoring: Out Of Range
  • Out of range low:
  • Negative engine speed deviation from set point > 100 RPM
  • Or
  • Out of range high:
  • Positive engine speed deviation from set point > 90 RPM
  • Gear switch not active
  • Vehicle speed = 0 mph
  • For time >= 0.0 s
  • Driver request not active
  • Throttle actuator commanded on
  • Evap purge flow < 4.0 kg/h
  • Torque safety limitation not active
  • Clutch switch n.a.
  • Barometric pressure > 69.99 kPa
  • Catalyst heating not active
  • ECT @ cylinder head > -48° C
  • Time after engine start > 0.0 s
  • Set point change n.a.
  • For time n.a.
  • 12.0 s
  • Continuous
  • 2 DCY
-- Check the Throttle Valve Control Module -GX3-. Refer to Throttle Valve Control Module - GX3-, CHECKING .
P050B Cold Start Ignition Timing Performance Ignition Control Ignition Timing Monitor
  • Ratio between ignition angle efficiency integral and time at idle speed > 0.20 [-]
  • Engine idle speed time @ idle speed > 5.0 s
  • Ignition angle set point <= 0.85 [-]
  • Modeled pressure quotient <= 1.0 [-]
  • Vehicle speed = 0.0 miles
  • And
  • Diff. air mass set point vs. filtered air mass set point for load dynamic detection < 99, 999.0 mg/stk
  • For time >= 0.0 s
  • And
  • Diff. engine speed vs. filtered engine speed for engine speed dynamic detection < 8, 160 RPM
  • For time >= 0.0 s
  • 0.1 s
  • Once / DCY
  • 2 DCY
-- Check for any engine speed sensor or ignition coil faults and diagnose them first. If no other codes are set, replace the Engine Control Module -J623-. Refer to appropriate repair information.-- Check the Engine Speed Sensor -G28-. Refer to Engine Speed Sensor - G28-, CHECKING .-- Check the Ignition Coils with Power Output Stage --. Refer to Ignition Coils with Power Output Stage --, CHECKING .
P053F Cold Start Fuel Pressure Performance Fuel System Out Of Range High
  • Deviation between reference and actual fuel pressure < -2, 000.10 kPa
  • For time >= 3.0 s
  • Engine speed > 608 RPM
  • Catalyst heating active
  • ECT @ cylinder head > -48 [°C]
  • Time after engine start > 7.0 [s]
  • Mass fuel flow set point >= 5.0 mg/stk
  • For time >= 3.0 s
  • And
  • Mass fuel flow > 1.99 mg/stk
  • For time >= 5.0 s
  • And
  • Fuel pump delivery range < 72.0 - 145.0 mg/stk
  • Gradient mass fuel flow per stroke -1, 389.0 - 1, 389.0 mg/stk
  • For time >= 5.0 s
  • 5.0 s
  • Once / DCY
  • 2 DCY
-- Check the fuel pressure and delivery quantity. Refer to fuel system mechanical testing in PRELIMINARY CHECK and/or to appropriate repair information.-- Check the Fuel Delivery Unit -GX1- / Fuel Pump Control Module -J538-. Refer to Fuel Delivery Unit -GX1- / Fuel Pump Control Module -J538-, CHECKING .-- Check the Fuel Metering Valve -N290-. Refer to Fuel Metering Valve - N290-, CHECKING .-- Check the Fuel Pressure Sensor -G247-. Refer to Fuel Pressure Sensor - G247-, CHECKING .
Fuel System Out Of Range Low
  • Deviation between reference and actual fuel pressure > 2, 000.10 kPa
  • For time >= 3.0 s
P0601 Internal Control Module Memory Check Sum Error ECM: Checksum Verification
  • Calibration checksum incorrect
  • Software checksum incorrect
 
  • 1.0 s
  • Continuous
  • 2 DCY
-- Check the Engine Control Module -J623-. Refer to appropriate repair information.
P0603 Internal Control Module Keep Alive Memory (KAM) Error Injection Valves Supply Voltage Internal Hardware Check
  • Hardware vs. software version check during initialization failure
  • Calibration during initialization failure
  • Hardware during initialization failure
  • Time reference from microcontroller during initialization failure
  • Time reference from microcontroller during initialization missing
  • Communication between microcontroller and SDI-Driver powerstage failed
 
  • 4.9 s
  • Once / DCY
  • 2 DCY
-- Check the Engine Control Module -J623-. Refer to appropriate repair information.
ECM: Communication Check
  • SPI communication with ATIC failure
 
  • 2.0 s
  • Continuous
P0606 Control Module Processor By Engine Off: Barometric Pressure Sensor Rationality Check
  • Diff. barometric pressure vs. upstream throttle pressure >= 8.50 kPa
  • Or
  • Diff. barometric pressure vs. intake manifold pressure >= 8.50 kPa
  • Case 1:
  • Engine stop during DCY
  • Engine stop active
  • Vehicle speed < 1 mph
  • Delay after engine stop > 5.0 s
  • For time >= 10.0 s
  • Case 2:
  • Engine stop at start of DCY
  • Engine stopped
  • Vehicle speed < 1 mph
  • Delay after engine stop >= 5.0 s
  • 3.0 s
  • Continuous
  • 2 DCY
-- NOTE: The BARO sensor is an internal part of the ECM and is not repairable. If the BARO reading is off by more than 10%, replace the Engine Control Module -J623-. Refer to appropriate repair information.-- Check the Engine Control Module -J623-. Refer to appropriate repair information.
During ECM Keep Alive-Time: Barometric Pressure Sensor Rationality Check
  • Diff. barometric pressure vs. intake manifold pressure > 8.50 kPa
  • Diff. intake manifold pressure vs. intake manifold pressure @ idle or low part load >= n.a. kPa
  • Or
  • Diff. barometric pressure vs. upstream throttle pressure >= 8.50 kPa
  • Diff. upstream throttle pressure @ full or high part load vs. upstream throttle pressure >= n.a. kPa
  • Engine stop active
  • Vehicle speed < 1 mph
  • Ignition off
  • Delay time in ECM keep alive-time > 10.0 s
  • Delay after engine stop >= 5.0 s
  • Barometric pressure sensor voltage 0.20 - 4.80 V
  • Intake manifold pressure sensor voltage 0.20 - 4.80 V
  • Turbocharger boost pressure sensor voltage 0.20 - 4.80 V
Out Of Range
  • High:
  • Measured barometric pressure > 115.0 kPa
  • Low:
  • Measured barometric pressure < 45.0 kPa
 
  • 5.0 s
  • Continuous
Knock Control Functional Check
  • Knock control failure
  • Engine running
  • 6.4 s
  • Continuous
EEPROM Check
  • EEPROM information failure
  • Decryption of NVMCrypt failed
  • Finished NVMCrypt integrity error
  • Communication between sample software and production hardware error
  • RAM error detected
  • Monitoring module check failed
 
  • 1.0 s
  • Once / DCY
ECM: Communication Check
  • SPI communication with ATIC failure
  • 2.0 s
  • Continuous
P0607 Control Module Performance Barometric Pressure Sensor Short To Ground
  • YES: voltage < 0.20 V
 
  • 0.5 s
  • Continuous
  • 2 DCY
-- NOTE: The BARO sensor is an internal part of the ECM and is not repairable. If the BARO reading is off by more than 10%, replace the Engine Control Module -J623-. Refer to appropriate repair information.-- Check the Engine Control Module -J623-. Refer to appropriate repair information.
Barometric Pressure Sensor Short To Battery Voltage
  • Barometric pressure sensor voltage > 4.80 V
P0638 Throttle Actuator Control Range / Performance Throttle Actuator Basic Settings, Adaptation Value Monitoring, Monitoring Of Position
  • Battery voltage <= 9.04 V
  • Accelerator pedal value > 99.9%
  • Or
  • Engine speed > 64 RPM
  • Or
  • Vehicle speed > 1 mph
  • Or
  • Modeled IAT @ throttle < 5° C
  • Or
  • ECT @ cylinder head < 5° C
  • Or
  • ECT @ cylinder head > 110° C
  • Actual TPS - ref. point > 0.503° TPS
  • Throttle position sensor 1 voltage < 0.40 V
  • Or
  • Throttle position sensor 2 voltage > 4.60 V
  • Or
  • Throttle position sensor 1 voltage > 0.80 V
  • Or
  • Throttle position sensor 2 voltage < 4.20 V
  • Actual TPS 1 or 2 voltage - voltage ref. point > 0.07 V
  • Actual TPS 1 or 2 voltage - voltage ref. point > 0.25 V
  • Actual TPS - ref. point > 0.503° TPS
  • Actual TPS 1 or 2 voltage - voltage ref. point > 0.07 V
  • Throttle adaptation demanded
  • Accelerator pedal value < 99.9%
  • Engine speed < 64 RPM
  • Vehicle speed < 1 mph
  • Modeled IAT @ throttle > 5° C
  • ECT @ cylinder head 5 - 110° C
  • 0.01 s
  • Once per lifetime
  • 2 DCY
-- Check the Engine Control Module -J623-. Refer to appropriate repair information.
P0642 Sensor Reference Voltage "A" Circuit Low ECM: 5V Supply Voltage Out Of Range Low
  • Analog output 1 supply voltage < 4.62 V
 
  • 0.2 s
  • Continuous
  • 2 DCY
-- If a related sensor voltage code is also set, refer to that sensor for diagnosis first. If no other related codes set, replace the Engine Control Module -J623-. Refer to appropriate repair information.
P0643 Sensor Reference Voltage "A" Circuit High ECM: 5V Supply Voltage Out Of Range High
  • Analog output 1 supply voltage > 5.43 V
 
  • 0.2 s
  • Continuous
  • 2 DCY
-- If a related sensor voltage code is also set, refer to that sensor for diagnosis first. If no other related codes set, replace the Engine Control Module -J623-. Refer to appropriate repair information.
P0652 Sensor Reference Voltage "B" Circuit Low ECM: 5V Supply Voltage Out Of Range Low
  • Analog output 1 supply voltage < 4.62 V
 
  • 0.2 s
  • Continuous
  • 2 DCY
-- If a related sensor voltage code is also set, refer to that sensor for diagnosis first. If no other related codes set, replace the Engine Control Module -J623-. Refer to appropriate repair information.
P0653 Sensor Reference Voltage "B" Circuit High ECM: 5V Supply Voltage Out Of Range High
  • Analog output 1 supply voltage > 5.43 V
 
  • 0.2 s
  • Continuous
  • 2 DCY
-- If a related sensor voltage code is also set, refer to that sensor for diagnosis first. If no other related codes set, replace the Engine Control Module -J623-. Refer to appropriate repair information.
P0657 Actuator Supply Voltage "A" Circuit Open Supply Voltage Relay Engine Components Open Circuit
  • Output voltage, lower range >= 1.90 - 2.30 V
  • Output voltage, upper range (hardware values) <= 2.80 - 3.20V
  • Relay commanded off
  • 1.0 s
  • Continuous
  • 2 DCY
-- Check the Engine Component Power Supply Relay -J757-. Refer to Engine Component Power Supply Relay - J757-, CHECKING .
P0658 Actuator Supply Voltage "A" Circuit Low Supply Voltage Relay Engine Components Short To Ground
  • Output voltage (hardware values) < 1.90 - 2.28 V
  • Relay commanded off
  • 1.0 s
  • Continuous
  • 2 DCY
-- Check the Engine Component Power Supply Relay -J757-. Refer to Engine Component Power Supply Relay - J757-, CHECKING .
P0659 Actuator Supply Voltage "A" Circuit High Supply Voltage Relay Engine Components Short To Battery Voltage
  • Output current > 1.0 - 2.3 A
  • Or
  • Actuator temperature (hardware values) > 175 - 195° C
  • Relay commanded on
  • 1.0 s
  • Continuous
  • 2 DCY
-- Check the Engine Component Power Supply Relay -J757-. Refer to Engine Component Power Supply Relay - J757-, CHECKING .
P0686 ECM / PCM Power Relay Control Circuit Low Main Relay Rationality Check During Engine Off
  • Sensed circuit voltage > 6.0 V
  • Main relay commanded on
  • For time>= 0.3 s
  • 0.1 s
  • Continuous
  • 2 DCY
-- Check the Motronic Engine Control Module Power Supply Relay -J271-. Refer to Motronic Engine Control Module Power Supply Relay - J271-, CHECKING .
P0687 ECM / PCM Power Relay Control Circuit High Main Relay Rationality Check During Engine On
  • Sensed circuit voltage < 5.0 V
  • Main relay commanded on
  • For time>= 0.1 s
  • 0.1 s
  • Continuous
  • 2 DCY
-- Check the Motronic Engine Control Module Power Supply Relay -J271-. Refer to Motronic Engine Control Module Power Supply Relay - J271-, CHECKING .
Main Relay Short To Battery Voltage
  • Main relay driver temperature > 175 - 195° C
  • Or
  • Main relay output current (hardware values) > 1.0 - 2.3 A
  • Main relay commanded on
  • For time>= 0.4 s
  • 0.2 s
  • Continuous
P0698 Sensor Reference Voltage "C" Circuit Low ECM: 5V Supply Voltage Out Of Range Low
  • Analog output 1 supply voltage < 4.62 V
 
  • 0.2 s
  • Continuous
  • 2 DCY
-- If a related sensor voltage code is also set, refer to that sensor for diagnosis first. If no other related codes set, replace the Engine Control Module -J623-. Refer to appropriate repair information.
P0699 Sensor Reference Voltage "C" Circuit High ECM: 5V Supply Voltage Out Of Range High
  • Analog output 1 supply voltage > 5.43 V
 
  • 0.2 s
  • Continuous
  • 2 DCY
-- If a related sensor voltage code is also set, refer to that sensor for diagnosis first. If no other related codes set, replace the Engine Control Module -J623-. Refer to appropriate repair information.
P11A1 Cyl. 1 Exhaust Cam Low Lift Electrical Fault    
  • Switching active
  • Check for open / short circuit to battery voltage
  • Switching not active
  • Check for Short to ground
  • 0.3 s
  • 2 DCY
-- Check the Cam Adjustment Actuators --. Refer to Cam Adjustment Actuators --, CHECKING .
P11A2 Cyl. 1 Functional Test, Fault Switching To Low Exhaust Cam Lift    
  • Begin diagnostic window, once every start up
  • > 430.125 KW
  • 0.4 s
  • 2 DCY
-- Check the Cam Adjustment Actuators --. Refer to Cam Adjustment Actuators --, CHECKING .
P11A3 Cyl. 2 Exhaust Cam Low Lift Electrical Fault    
  • Switching active
  • Check for open / short circuit to battery voltage
  • Switching not active
  • Check for short to ground
  • 0.3 s
  • 2 DCY
-- Check the Cam Adjustment Actuators --. Refer to Cam Adjustment Actuators --, CHECKING .
P11A4 Cyl. 2 Functional Test, Fault Switching To Low Exhaust Cam Lift    
  • Begin diagnostic window, once every start up
  • > 430.125 KW
  • 0.4 s
  • 2 DCY
-- Check the Cam Adjustment Actuators --. Refer to Cam Adjustment Actuators --, CHECKING .
P11A5 Cyl. 3 Exhaust Cam Low Lift Electrical Fault    
  • Switching active
  • Check for open / short circuit to battery voltage
  • Switching not active
  • Check for short to ground
  • 0.3 s
  • 2 DCY
-- Check the Cam Adjustment Actuators --. Refer to Cam Adjustment Actuators --, CHECKING .
P11A6 Cyl. 3 Functional Test, Fault Switching To Low Exhaust Cam Lift    
  • Begin diagnostic window, once every start up
  • > 430.125 KW
  • 0.4 s
  • 2 DCY
-- Check the Cam Adjustment Actuators --. Refer to Cam Adjustment Actuators --, CHECKING .
P11A7 Cyl. 4 Exhaust Cam Low Lift Electrical Fault    
  • Switching active
  • Check for open / short circuit to battery voltage
  • Switching not active
  • Check for short to ground
  • 0.3 s
  • 2 DCY
-- Check the Cam Adjustment Actuators --. Refer to Cam Adjustment Actuators --, CHECKING .
P11A8 Cyl. 4 Functional Test, Fault Switching To Low Exhaust Cam Lift    
  • Begin diagnostic window, once every start up
  • > 430.125 KW
  • 0.4 s
  • 2 DCY
-- Check the Cam Adjustment Actuators --. Refer to Cam Adjustment Actuators --, CHECKING .
P12A1 Fuel System Pressure Sensor, High Pressure Side Rationality Check Low Fuel System Pressure Sensor, High Pressure Side Rationality Check Low
  • Fuel mass controller output < -35.0%
  • And
  • High pressure controller output > 15.0 mg
  • Engine speed 608 - 6, 816 RPM
  • Mass fuel flow set point 4.01 - 30.01 mg/stk
  • For time after request for mass fuel flow set point >= 5.0 s
  • Time after change to DFI >= 0.0 s
  • Time after engine start > 10.0 s
  • Engine warm-up n.a.
  • Catalyst heating n.a.
  • Full load n.a.
  • Catalyst purge not active
  • Lambda control closed loop
  • Evap purge functionality diagnosis n.a.
  • 5.0 s
  • Continuous
  • 2 DCY
-- Check the fuel pressure and delivery quantity. Refer to fuel system mechanical testing in PRELIMINARY CHECK and/or to appropriate repair information.-- Check the Fuel Pressure Sensor -G247-. Refer to Fuel Pressure Sensor - G247-, CHECKING .-- Check the Fuel Delivery Unit -GX1- / Fuel Pump Control Module -J538-. Refer to Fuel Delivery Unit -GX1- / Fuel Pump Control Module -J538-, CHECKING .
P12A2 Fuel System Pressure Sensor, High Pressure Side Rationality Check High Fuel System Pressure Sensor, High Pressure Side Rationality Check High
  • Fuel mass controller output > 30.0%
  • And
  • High pressure controller output < -15.0 mg
  • Engine speed 608 - 6, 816 RPM
  • Mass fuel flow set point 4.01 - 30.01 mg/stk
  • For time after request for mass fuel flow set point >= 5.0 s
  • Time after change to DFI >= 0.0 s
  • Time after engine start > 10.0 s
  • Engine warm-up n.a.
  • Catalyst heating n.a.
  • Full load n.a.
  • Catalyst purge not active
  • Lambda control closed loop
  • Evap purge functionality diagnosis n.a.
  • And
  • Choice of:
  • Canister load <= n.a. [-]
  • Or
  • Evap purge valve n.a.
  • 4.5 s
  • Continuous
  • 2 DCY
-- Check the fuel pressure and delivery quantity. Refer to fuel system mechanical testing in PRELIMINARY CHECK and/or to appropriate repair information.-- Check the Fuel Pressure Sensor -G247-. Refer to Fuel Pressure Sensor - G247-, CHECKING .-- Check the Fuel Delivery Unit -GX1- / Fuel Pump Control Module -J538-. Refer to Fuel Delivery Unit -GX1- / Fuel Pump Control Module -J538-, CHECKING .
P12A4 Fuel System Pressure Sensor, High Pressure Side Out Of Range High Fuel System Pressure Sensor, High Pressure Side Out Of Range High
  • Deviation between fuel pressure set point and current fuel pressure < -2, 000.10 kPa
  • Fuel mass controller output -50.0 - 50.0%
  • Case 1:
  • High pressure controller output < -30.0 mg
  • Case 2:
  • Flow control valve open mass fuel flow set point > 15.01 mg/stk
  • Engine speed 608 - 6, 816 RPM
  • Mass fuel flow set point 15.01 - 1, 389.0 mg/stk
  • For time after request for mass fuel flow set point >= 5.0 s
  • Engine start not active
  • Time after engine start > 10.0 s
  • Engine warm-up n.a.
  • Catalyst heating not active
  • Full load n.a.
  • Catalyst purge n.a.
  • Lambda control n.a.
  • Evap purge functionality diagnosis n.a.
  • And
  • Choice of:
  • Canister load <= n.a. [-]
  • Or
  • Evap purge valve n.a.
  • 4.5 s
  • Continuous
  • 2 DCY
-- Check the fuel pressure and delivery quantity. Refer to fuel system mechanical testing in PRELIMINARY CHECK and/or to appropriate repair information.-- Check the Fuel Pressure Sensor -G247-. Refer to Fuel Pressure Sensor - G247-, CHECKING .-- Check the Fuel Delivery Unit -GX1- / Fuel Pump Control Module -J538-. Refer to Fuel Delivery Unit -GX1- / Fuel Pump Control Module -J538-, CHECKING .
P13EA Off Idle: Cold Start Ignition Timing Performance Ignition Control Ignition Timing Monitor
  • Ratio between ignition angle efficiency integral and time at part load > 0.25 [-]
  • Time @ part load > 5.0 s
  • Ignition angle set point <= 0.94 [-]
  • Engine part load
  • Vehicle speed > 2 mph
  • And
  • Diff. air mass set point vs. filtered air mass set point for load dynamic detection < 99, 999.0 mg/stk
  • For time >= 0.0 s
  • And
  • Diff. engine speed vs. filtered engine speed for engine speed dynamic detection < 8, 160 RPM]
  • For time >= 0.0 s
  • 0.1 s
  • Once / DCY
  • 2 DCY
-- Check for any engine speed sensor or ignition coil faults and diagnose them first. If no other codes are set, replace the Engine Control Module -J623-. Refer to appropriate repair information.
P1545 Throttle Valve Control - Malfunction Throttle Actuator Out Of Range
  • Control duty cycle > 98.0%
  • Throttle position not at min. value
  • Throttle adaptation not active
  • Throttle actuator commanded on
  • 5.0 s
  • Continuous
  • 2 DCY
-- Check the Throttle Valve Control Module -GX3-. Refer to Throttle Valve Control Module - GX3-, CHECKING .
Rationality Check
  • Difference between throttle position set point and throttle flap opening angle for electronic throttle control > 2.998 - 24.982° TPS
  • Throttle adaptation not active
  • Throttle actuator commanded on
  • Difference between throttle position set point and throttle flap opening angle <= 1.999; > -1.999° TPS
P169A Vehicle In Transport Mode ECM: Transport Mode Function Monitoring: Mode Change
  • Transport mode active
  • Vehicle speed < 3 mph
  • Max trip mileage since initial vehicle start-up < 62.15 miles
  • During ECM keep alive-time after ignition off engine speed 0 RPM
  • Production mode not active
  • For hybrid:
  • Drive motor off
  • 0.01 s
  • Continuous
  • 1DCY
-- Vehicle is in Transport Mode (Loading Mode). It can be turned off with a scan tool or will automatically switch off after approximately 100 km (62.15 miles) have accumulated on the vehicle. May need to perform readiness check. Refer to READINESS CODE .
P2006 Intake Manifold Runner Control Stuck Closed Intake Manifold Runner Flap Actuator Stuck Closed
  • Diff. actual value vs. substitution value @ lower mechanical threshold > 0.70 V
  • Or
  • Diff. actual value vs. substitution value @ upper mechanical threshold > 0.70 V
  • Failed adaptations >= 1.0 [-]
  • For time >= 1.5 s
  • Flap commanded on
  • Time after engine start > 5.0 s
  • 0.2 s
  • Continuous
  • 2 DCY
-- Check the Intake Manifold Runner Control Valve -N316-. Refer to Intake Manifold Runner Control Valve - N316-, CHECKING .
P2008 Intake Manifold Runner Control Circuit / Open Intake Manifold Runner Flap Actuator Open Circuit
  • Output voltage, lower range (hardware values) 1.92 - 2.21 V
  • Engine running
  • 2.0 s
  • Continuous
  • 2 DCY
-- Check the Intake Manifold Runner Control Valve -N316-. Refer to Intake Manifold Runner Control Valve - N316-, CHECKING .
P2009 Intake Manifold Runner Control Circuit Low Intake Manifold Runner Flap Actuator Short To Ground
  • Output voltage (hardware values) < 1.92 - 2.21 V
  • Engine running
  • Actuator commanded off
  • 2.0 s
  • Continuous
  • 2 DCY
-- Check the Intake Manifold Runner Control Valve -N316-. Refer to Intake Manifold Runner Control Valve - N316-, CHECKING .
P2010 Intake Manifold Runner Control Circuit High Intake Manifold Runner Flap Actuator Short To Battery Voltage
  • Power stage temperature > 160 - 200° C
  • Or
  • output current (hardware values) > 4.0 - 7.0 A
  • Engine running
  • Actuator commanded off
  • 2.0 s
  • Continuous
  • 2 DCY
-- Check the Intake Manifold Runner Control Valve -N316-. Refer to Intake Manifold Runner Control Valve - N316-, CHECKING .
P2014 Intake Manifold Runner Position Sensor Circuit Intake Manifold Runner Flap Position Sensor Short To Ground / Open Circuit
  • Intake manifold runner flap position sensor voltage < 0.20 V
 
  • 0.04 s
  • Continuous
  • 2 DCY
-- Check the Intake Manifold Runner Position Sensor -G336-. Refer to Intake Manifold Runner Position Sensor - G336-, CHECKING .
P2015 Intake Manifold Runner Position Sensor Circuit Range / Performance Intake Manifold Runner Flap Actuator Adaptation Value Monitoring
  • Diff. actual value vs. substitution value @ lower mechanical thresh hold > 0.70 V
  • Or
  • Diff. actual value vs. substitution value @ upper mechanical thresh hold > 0.70 V
  • Failed adaptations >= 1.0 [-]
  • For time >= 1.5 s
  • Modeled air temperature < 0.75 [-]
  • Engine running
  • Engine speed > 640; < 1, 504 RPM
  • ECT @ cylinder head > -30° C
  • Intake manifold runner flap adaptation not finished
  • Time after engine start > 5.0 s
  • 0.04 s
  • Continuous
  • 2 DCY
-- Check the Intake Manifold Runner Position Sensor -G336-. Refer to Intake Manifold Runner Position Sensor - G336-, CHECKING .
P2017 Intake Manifold Runner Position Sensor Circuit High Intake Manifold Runner Flap Position Sensor Short To Battery Voltage
  • Intake manifold runner flap position sensor voltage > 4.80 V
 
  • 0.04 s
  • Continuous
  • 2 DCY
-- Check the Intake Manifold Runner Position Sensor -G336-. Refer to Intake Manifold Runner Position Sensor - G336-, CHECKING .
P2024 Evaporative Emissions (EVAP) Fuel Vapor Temperature Sensor Circuit Smart Temperature Sensor Open Circuit
  • NVLD output voltage lower range >= 1.92 - 2.21 V
  • NVLD output voltage upper range <= 2.85 - 3.25 V
  • Case 1:
  • Ignition on engine running
  • Case 2:
  • Ignition off (during ECM keep alive-time)
  • 0.5 s
  • Continuous
  • 2 DCY
-- Check the Fuel Tank Leak Detection Control Module -J909-. Refer to Fuel Tank Leak Detection Control Module - J909-, CHECKING .
P2025 Evaporative Emissions (EVAP) Fuel Vapor Temperature Sensor Performance Smart Temperature Sensor: Functional Check
  • Diff. time between ECU and smart module > 3.0 s
  • Ignition off
  • NVLD (EVAP-System) diagnostic mode = active
  • 3.0 s
  • Once / DCY
  • 2 DCY
-- Check the Fuel Tank Leak Detection Control Module -J909-. Refer to Fuel Tank Leak Detection Control Module - J909-, CHECKING .
  • Reset counter > 3.0 [-]
  • Engine running
  • Last ECM keep alive mode finished
  • 300.0 s
  • Continuous
Smart Temperature Sensor: Out Of range High
  • Smart module temperature > 119° C
  • Engine running
  • 30 s
  • Continuous
Smart Temperature Sensor: Out of range Low
  • Smart module temperature < -39° C
  • Cold start detected
  • ECT @ cylinder head > 26° C
  • IAT cross check finished
  • ECT cross check finished
  • 1.0 s
  • Once / DCY
Smart Temperature Sensor: Cross Check
  • Difference between smart temperature and ECT @ cylinder head >= 25.5 K
  • And
  • Difference between smart temperature and IAT @ manifold >= 25.5 K
  • Cold start detected
  • IAT cross check finished
  • ECT cross check finished
Smart Temperature Sensor: Signal Dynamic check
  • Gradient smart temperature > 20 K/10min
  • Ignition off
  • Fuel level < 85.10%
  • NVLD (EVAP-System) diagnostic mode = active
  • 300.0 s
  • Once / DCY
Communication With Smart Temperature Sensor
  • Response time > 1.0 s
  • And
  • Number of checks > 3.0 [-]
  • Or
  • Security bit incorrect
  • Case 1:
  • Ignition on engine running
  • Case 2:
  • Ignition off (during ECM keep alive-time)
  • 0.1 s
  • Once / DCY
  • 3 DCY
P2026 Evaporative Emissions (EVAP) Fuel Vapor Temperature Sensor Circuit Low Voltage Smart Temperature Sensor Short To Ground
  • NVLD output voltage < 1.92 - 2.21 V
  • Case 1:
  • Ignition on engine running
  • Case 2:
  • Ignition off (during ECM keep alive-time)
  • 0.5 s
  • Continuous
  • 2 DCY
-- Check the Fuel Tank Leak Detection Control Module -J909-. Refer to Fuel Tank Leak Detection Control Module - J909-, CHECKING .
P2027 Evaporative Emissions (EVAP) Fuel Vapor Temperature Sensor Circuit High Voltage Smart Temperature Sensor Short To Battery Voltage
  • NVLD output temperature > 160.0 - 200.0° C
  • Or
  • NVLD output current 4.0 - 7.0 A
  • Case 1:
  • Ignition on engine running
  • Case 2:
  • Ignition off (during ECM keep alive-time)
  • 0.5 s
  • Continuous
  • 2 DCY
-- Check the Fuel Tank Leak Detection Control Module -J909-. Refer to Fuel Tank Leak Detection Control Module - J909-, CHECKING .
P2088 Intake Camshaft Position Actuator Control Circuit Low VVT Actuator Intake Short To Ground
  • Output voltage < 1.92 - 2.21 V
  • Actuator commanded off
  • 2.0 s
  • Continuous
  • 2 DCY
-- Check the Camshaft Adjustment Valve 1 -N205-. Refer to Camshaft Adjustment Valve 1 - N205-, CHECKING .
P2089 Intake Camshaft Position Actuator Control Circuit High VVT Actuator Intake Short To Battery Voltage
  • Power stage temperature > 160 - 200° C
  • Or
  • Output current (hardware values) > 8.0 - 12.0 A
  • Actuator commanded on
  • 2.0 s
  • Continuous
  • 2 DCY
-- Check the Camshaft Adjustment Valve 1 -N205-. Refer to Camshaft Adjustment Valve 1 - N205-, CHECKING .
P2090 "Exhaust" Camshaft Position Actuator Control Circuit Low VVT Actuator Outlet Short To Ground
  • Output voltage (hardware values) < 1.92 - 2.21 V
  • Actuator commanded off
  • 2.0 s
  • Continuous
  • 2 DCY
-- Check the Exhaust Camshaft Adjustment Valve 1 -N318-. Refer to Exhaust Camshaft Adjustment Valve 1 - N318-, CHECKING .
P2091 "Exhaust" Camshaft Position Actuator Control Circuit High VVT Actuator Outlet Short To Battery Voltage
  • Power stage temperature (hardware values) > 160 - 200° C
  • Actuator commanded on
  • 2.0 s
  • Continuous
  • 2 DCY
-- Check the Exhaust Camshaft Adjustment Valve 1 -N318-. Refer to Exhaust Camshaft Adjustment Valve 1 - N318-, CHECKING .
P2096 Post Catalyst Fuel Trim System Too Lean Fuel System Out Of Range Low
  • Adaption value > 0.05 [-]
  • 2nd lambda control n.a.
  • Catalyst purge not active
  • Engine speed >= 704 RPM
  • Integrated mass for fuel in oil < 255.0 [-]
  • Choice of:
  • O2S rear (binary) check not active
  • Or
  • O2S rear (binary) check finished
  • 5.0 s
  • Continuous
  • 2 DCY
-- Check exhaust system for leaks first and correct as necessary. -- Check the Oxygen Sensor 1 After Catalytic Converter -GX7-. Refer to Oxygen Sensor 1 After Catalytic Converter - GX7-, CHECKING .
P2097 Post Catalyst Fuel Trim System Too Rich Fuel System Out Of Range High
  • Adaption value < -0.05 [-]
  • 2nd lambda control n.a.
  • Catalyst purge not active
  • Engine speed >= 704 RPM
  • Integrated mass for fuel in oil < 255.0 [-]
  • Choice of:
  • O2S rear (binary) check not active
  • Or
  • O2S rear (binary) check finished
  • 5.0 s
  • Continuous
  • 2 DCY
-- Check exhaust system for leaks first and correct as necessary. -- Check the Oxygen Sensor 1 After Catalytic Converter -GX7-. Refer to Oxygen Sensor 1 After Catalytic Converter - GX7-, CHECKING .
P2100 Throttle Actuator "A" Control Motor Circuit/Open Throttle Actuator Open Circuit
  • electronic throttle valve driver load resistance > 200.0 kΩ
  • Difference between measured and filtered throttle position <= 0.073° TPS
  • Actuator commanded off
  • 0.1 s
  • Continuous
  • 2 DCY
-- Check the Throttle Valve Control Module -GX3-. Refer to Throttle Valve Control Module - GX3-, CHECKING .
P2101 Throttle Actuator "A" Control Motor Circuit Range / Performance Throttle Actuator Over Temp.
  • Electronic throttle valve driver temperature (hardware values) > 170.0 - 190.0° C
  • Actuator commanded on
  • 0.1 s
  • Continuous
  • 2 DCY
-- Check the Throttle Valve Control Module -GX3-. Refer to Throttle Valve Control Module - GX3-, CHECKING .
P2103 Throttle Actuator "A" Control Motor Circuit High Throttle Actuator Short Circuit
  • Electronic throttle valve driver current (hardware values) > 9.3 - 15.0 A
  • Actuator commanded on
  • 0.1 s
  • Continuous
  • 2 DCY
-- Check the Throttle Valve Control Module -GX3-. Refer to Throttle Valve Control Module - GX3-, CHECKING .
P2122 Throttle / Pedal Position Sensor / Switch "D" Circuit Low Accelerator Pedal Position Sensor 1 Out Of Range Low
  • Signal voltage sensor 1 < 0.40 V
 
  • 0.3 s
  • Continuous
  • 2 DCY
-- Check the Accelerator Pedal Module -GX2-. Refer to Accelerator Pedal Module - GX2-, CHECKING .
P2123 Throttle / Pedal Position Sensor / Switch "D" Circuit High Accelerator Pedal Position Sensor 1 Out Of Range High
  • Signal voltage sensor 1 > 4.82 V
 
  • 0.3 s
  • Continuous
  • 2 DCY
-- Check the Accelerator Pedal Module -GX2-. Refer to Accelerator Pedal Module - GX2-, CHECKING .
P2127 Throttle / Pedal Position Sensor/Switch "E" Circuit Low Accelerator Pedal Position Sensor 2 Out Of Range Low
  • Signal voltage sensor 2 < 0.20 V
 
  • 0.3 s
  • Continuous
  • 2 DCY
-- Check the Accelerator Pedal Module -GX2-. Refer to Accelerator Pedal Module - GX2-, CHECKING .
P2128 Throttle / Pedal Position Sensor/Switch "E" Circuit High Accelerator Pedal Position Sensor 2 Out Of Range High
  • Signal voltage sensor 2 > 2.80 V
 
  • 0.3 s
  • Continuous
  • 2 DCY
-- Check the Accelerator Pedal Module -GX2-. Refer to Accelerator Pedal Module - GX2-, CHECKING .
P2138 Throttle / Pedal Position Sensor/Switch "D"/"E" Voltage Correlation Accelerator Pedal Position Sensor 1 And 2 Rationality Check
  • Difference between signal voltage sensor 1 and sensor 2 > 0.10 - 0.12 V
 
  • 0.4 s
  • Continuous
  • 2 DCY
-- Check the Accelerator Pedal Module -GX2-. Refer to Accelerator Pedal Module - GX2-, CHECKING .
P2177 System Too Lean Off Idle Bank 1 Fuel System Direct Fuel Injection System Too Lean
  • Adaptive value >= 30.0%
  • MAF > 60.0 mg/stk
  • Engine speed > 576 RPM
  • ECT @ cylinder head > 20° C
  • IAT @ manifold > -48° C
  • AAT > -48° C
  • Lambda set point 0.95 - 1.05 [-]
  • Lambda control closed loop
  • Integrated MAF >= 5.0 - 200.0 g
  • Lambda adaptation active
  • Vehicle speed < 4 mph
  • Driver request low dynamics
  • And
  • Mass fuel flow lower range > 0.0 mg/stk
  • Mass fuel flow upper range < 0.0 - 17.74 mg/stk
  • Or
  • Evap purge valve closed
  • Or
  • Canister load <= 1.20 [-]
  • Evap purge flow at max. value
  • Or
  • Depending on canister purge min:
  • Lower limit of lambda controller output n.a.
  • Or
  • Upper limit of lambda controller output n.a.
  • And
  • Evap purge flow at min. value
  • Barometric pressure > 73.0 kPa
  • 5.0 s
  • Continuous
  • 2 DCY
-- Check the intake and vacuum hoses for leaks, Check the Positive Crankcase Ventilation, also make sure the oil dipstick is properly secured.-- Listen to and visually inspect the Exhaust system to insure there are no leaks.-- Check the Oxygen Sensor 1 Before Catalytic Converter -GX10-. Refer to Oxygen Sensor 1 Before Catalytic Converter - GX10-, CHECKING .-- Check the Oxygen Sensor 1 After Catalytic Converter -GX7-. Refer to Oxygen Sensor 1 After Catalytic Converter - GX7-, CHECKING .-- Check the Intake Manifold Sensor -GX9-. Refer to Intake Manifold Sensor - GX9-, CHECKING .-- Check the EVAP Canister Purge Regulator Valve 1 -N80-. Refer to EVAP Canister Purge Regulator Valve 1 - N80-, CHECKING .-- Check the Fuel Injectors --. Refer to Fuel Injectors --, CHECKING .
P2178 System Too Rich Off Idle Bank 1 Fuel System Direct Fuel Injection System Too Rich
  • Adaptive value <= -30.0%
  • MAF > 60.0 mg/stk
  • Engine speed > 576 RPM
  • ECT @ cylinder head > 20° C
  • IAT @ manifold > -48° C
  • AAT > -48° C
  • Lambda set point 0.95 - 1.05 [-]
  • Lambda control closed loop
  • Integrated MAF >= 5.0 - 200.0 g
  • Lambda adaptation active
  • Vehicle speed < 4 mph
  • Driver request low dynamics
  • And
  • Mass fuel flow lower range > 0.0 mg/stk
  • Mass fuel flow upper range < 0.0 - 17.74 mg/stk
  • Or
  • Evap purge valve closed
  • Or
  • Canister load <= 1.20 [-]
  • Evap purge flow at max. value
  • Or
  • Depending on canister purge min:
  • Lower limit of lambda controller output n.a.
  • Or
  • Upper limit of lambda controller output n.a.
  • And
  • Evap purge flow at min. value
  • Barometric pressure > 73.0 kPa
  • 5.0 s
  • Continuous
  • 2 DCY
-- Check the EVAP system for possible fuel contamination. Refer to appropriate repair information.-- Check the Oxygen Sensor 1 Before Catalytic Converter -GX10-. Refer to Oxygen Sensor 1 Before Catalytic Converter - GX10-, CHECKING .-- Check the Oxygen Sensor 1 After Catalytic Converter -GX7-. Refer to Oxygen Sensor 1 After Catalytic Converter - GX7-, CHECKING .-- Check the Intake Manifold Sensor -GX9-. Refer to Intake Manifold Sensor - GX9-, CHECKING .-- Check the Fuel Injectors --. Refer to Fuel Injectors --, CHECKING .
P2181 Cooling System Performance Engine Cooling System Rationality Check
  • Modeled ECT @ cylinder head > 66 - 70° C
  • Choice of:
  • ECT @ cylinder head < 65 - 69° C
  • Or
  • ECT @ radiator outlet < n.a. ° C
  • ECT @ cylinder head @ first start >= -10° C
  • ECT @ cylinder head @ first start <= 50 - 55° C
  • AAT > -10° C
  • Ratio fuel cut off <= 10.16%
  • Ratio engine load time <= 39.84%
  • Ratio maximum vehicle speed <= 14.84%
  • Ratio start-stop time <= 16.02%
  • Set point of RVC in measurement window < 99.61%
  • Case 1:
  • Engine speed < 8, 160 RPM
  • Case 2:
  • Engine speed >= 8, 160 RPM
  • Diff. ECT@ cylinder head during measurement < 256° C
  • For time >= 0.0 s
  • 1.0 s
  • Once / DCY
  • 2 DCY
-- Check cooling system for leaks or damaged components-- Check the Engine Temperature Control Actuator -N493-. Refer to Engine Temperature Control Actuator - N493-, CHECKING .-- Check the Engine Coolant Temperature Sensor -G62-. Refer to Engine Coolant Temperature Sensor - G62-, CHECKING .
P2183 Engine Coolant Temperature Sensor 2 Circuit Range/Performance Engine Coolant Temperature Sensor @ Radiator Outlet Cross Check
  • High side:
  • Diff. ECT @ radiator outlet @ cold start vs. IAT @ manifold @ cold start > 25.0 K
  • Diff. ECT @ radiator outlet @ cold start vs. AAT @ cold start > 25.0 K
  • Low side:
  • Diff. IAT @ manifold @ cold start vs. ECT @ radiator outlet @ cold start > 25.0 K
  • Diff. AAT @ cold start vs. ECT @ radiator outlet @ cold start > 25.0 K
  • Engine off time >= 360.0 min
  • Engine off time plausible time after engine start <= 1, 400.0 s
  • Depending on temperature slope diff. actual vs previous IAT < 256.0 K
  • Diff. actual vs previous ECT@ cylinder head < 256.0 K
  • Diff. actual vs previous ECT@ radiator outlet < 256.0 K
  • Diff. actual vs previous AAT < 256.0 K
  • For time >= 1.0 s
  • 0.1 s
  • Once / DCY
  • 2 DCY
-- Check the Engine Coolant Temperature Sensor On Radiator Outlet -G83-. Refer to Engine Coolant Temperature Sensor On Radiator Outlet - G83-, CHECKING .
P2184 Engine Coolant Temperature Sensor 2 Circuit Low Engine Coolant Temperature Sensor @ Radiator Outlet Short To Ground
  • Sensor voltage < 0.30 V
 
  • 0.5 s
  • Continuous
  • 2 DCY
-- Check the Engine Coolant Temperature Sensor On Radiator Outlet -G83-. Refer to Engine Coolant Temperature Sensor On Radiator Outlet - G83-, CHECKING .
P2185 Engine Coolant Temperature Sensor 2 Circuit High Engine Coolant Temperature Sensor @ Radiator Outlet Short To Battery / Open Circuit
  • Sensor voltage > 4.90 V
  • Modeled IAT @ throttle >= -33° C
  • Time after engine start > 60.0 s
  • 0.5 s
  • Continuous
  • 2 DCY
-- Check the Engine Coolant Temperature Sensor On Radiator Outlet -G83-. Refer to Engine Coolant Temperature Sensor On Radiator Outlet - G83-, CHECKING .
P2187 Fuel System Too Lean At Idle Bank 1 Fuel System Direct Fuel Injection System Too Lean
  • Case 1:
  • Adaptive value >= 2.80 mg/stk
  • Case 2:
  • Adaptive value n.a.
  • MAF > 60.0 mg/stk
  • Engine speed > 576 RPM
  • ECT @ cylinder head > 20° C
  • IAT @ manifold > -48° C
  • AAT > -48° C
  • Lambda set point 0.95 - 1.05 [-]
  • Lambda control closed loop
  • Integrated MAF >= 5.0 - 200.0 g
  • Lambda adaptation active
  • Vehicle speed < 4 mph
  • Driver request low dynamics
  • And
  • Mass fuel flow lower range > 0.0 mg/stk
  • Mass fuel flow upper range < 0.0 - 17.74 mg/stk
  • Or
  • Evap purge valve closed
  • Or
  • Canister load <= 1.20 [-]
  • Evap purge flow at max. value
  • Or
  • Depending on canister purge min:
  • Lower limit of lambda controller output n.a.
  • Or
  • Upper limit of lambda controller output n.a.
  • And
  • Evap purge flow at min. value
  • Barometric pressure > 73.0 kPa
  • 5.0 s
  • Continuous
  • 2 DCY
-- Check the intake and vacuum hoses for leaks, Check the Positive Crankcase Ventilation, also make sure the oil dipstick is properly secured.-- Listen to and visually inspect the Exhaust system to insure there are no leaks.-- Check the Oxygen Sensor 1 Before Catalytic Converter -GX10-. Refer to Oxygen Sensor 1 Before Catalytic Converter - GX10-, CHECKING .-- Check the Oxygen Sensor 1 After Catalytic Converter -GX7-. Refer to Oxygen Sensor 1 After Catalytic Converter - GX7-, CHECKING .-- Check the Intake Manifold Sensor -GX9-. Refer to Intake Manifold Sensor - GX9-, CHECKING .-- Check the EVAP Canister Purge Regulator Valve 1 -N80-. Refer to EVAP Canister Purge Regulator Valve 1 - N80-, CHECKING .-- Check the Fuel Injectors --. Refer to Fuel Injectors --, CHECKING .
P2188 Fuel System Too Rich At Idle Bank 1 Fuel System Direct Fuel Injection System Too Rich
  • Case 1:
  • Adaptive value <= -3.01 mg/stk
  • Case 2:
  • Adaptive value <= n.a. kg/h
  • MAF > 60.0 mg/stk
  • Engine speed > 576 RPM
  • ECT @ cylinder head > 20° C
  • IAT @ manifold > -48° C
  • AAT > -48° C
  • Lambda set point 0.95 - 1.05 [-]
  • Lambda control closed loop
  • Integrated MAF >= 5.0 - 200.0 g
  • Lambda adaptation active
  • Vehicle speed < 4 mph
  • Driver request low dynamics
  • And
  • Mass fuel flow lower range > 0.0 mg/stk
  • Mass fuel flow upper range < 0.0 - 17.74 mg/stk
  • Or
  • Evap purge valve closed
  • Or
  • Canister load <= 1.20 [-]
  • Evap purge flow at max. value
  • Or
  • Depending on canister purge min:
  • Lower limit of lambda controller output n.a.
  • Or
  • Upper limit of lambda controller output n.a.
  • And
  • Evap purge flow at min. value
  • Barometric pressure > 73.0 kPa
  • 5.0 s
  • Continuous
  • 2 DCY
-- Check the Evaporative Emission (EVAP) System for contamination. -- Check the Oxygen Sensor 1 Before Catalytic Converter -GX10-. Refer to Oxygen Sensor 1 Before Catalytic Converter - GX10-, CHECKING .-- Check the Oxygen Sensor 1 After Catalytic Converter -GX7-. Refer to Oxygen Sensor 1 After Catalytic Converter - GX7-, CHECKING .-- Check the Fuel Injectors --. Refer to Fuel Injectors --, CHECKING .
P2195  O2 Sensor Signal Biased / Stuck Lean Bank 1, Sensor 1 Oxygen Sensors Front Rationality Check
  • Plausibility check upstream and downstream oxygen sensor signal:
  • Lambda value > 1.15 [-]
  • And
  • O2S signal rear >= 0.88 V
  • O2S front ready
  • O2S rear ready
  • ECT @ cylinder head >= -48° C
  • MAF > 15.0; < 300.0 kg/h
  • Catalyst purge not active
  • Integrated MAF after end of catalyst purge 0.0 [-]
  • Engine speed > 1, 152 RPM
  • EGT @ O2S front > -273; < 800° C
  • Integrated MAF > 40.0 g
  • Dynamic lambda controller output < 3.0%
  • Dynamic MAF < 0.05 g/rev
  • Dynamic engine speed < 200 RPM
  • And
  • Second control loop active:
  • MAF 0.06 - 0.75 g/rev
  • Engine speed 576 - 5, 088 RPM
  • 117.0 s
  • Continuous
  • 2 DCY
-- Check the Oxygen Sensor 1 Before Catalytic Converter -GX10-. Refer to Oxygen Sensor 1 Before Catalytic Converter - GX10-, CHECKING .
P2196  O2 Sensor Signal Biased / Stuck Rich Bank 1, Sensor 1 Oxygen Sensors Front Rationality Check
  • Plausibility check upstream and downstream oxygen sensor signal:
  • Lambda value < 0.85 [-]
  • And
  • O2S signal rear >= 0.25 V
  • Modeled exhaust gas temp 450 - 850 °C
  • Delta engine load < 35.0%
  • Exhaust. gas mass flow 14.0 - 300.0 kg/h
  • Lambda control, 2nd lambda control, closed loop
  • O2S front, rear and heaters ready - no fault
  • Fuel cutoff, catalyst heating, SAI - not active
  • 1st lambda control loop not at min or max
  • 2nd lambda control loop active
  • 117.0 s
  • Continuous
  • 2 DCY
-- Check the Oxygen Sensor 1 Before Catalytic Converter -GX10-. Refer to Oxygen Sensor 1 Before Catalytic Converter - GX10-, CHECKING .
P219C Cylinder 1 Air-Fuel Ratio Imbalance Air Fuel Imbalance Monitoring Out Of Range High Cyl. 1
  • Weighted adaptive value > 15.0%
  • Modeled catalyst temperature @ start <= 900° C
  • Lambda set value 0.97 - 1.03 [-]
  • Catalyst heating not active
  • Engine roughness signal valid
  • Cylinder shut off not active
  • AAT >= -48° C
  • Barometric pressure >= 73.0 kPa
  • And
  • Choice of: catalyst diagnosis n.a.
  • Or
  • Catalyst diagnosis n.a.
  • Depending on catalyst diagnosis:
  • Canister purge (conditions) n.a.
  • Or
  • Evap purge valve n.a.
  • Or
  • Evap purge n.a.
  • And
  • O2S dynamic diagnosis n.a.
  • O2S delay diagnosis n.a.
  • Lambda control closed loop
  • Catalyst purge not active
  • Canister load <= 2.0 [-]
  • Engine no full load
  • Fuel cut off not active
  • Segment adaptation finished
  • Catalyst damaging misfire not detected
  • Emission threshold misfire not detected
  • No gear switch for segments >= 90.0 [-]
  • Segments after start > 0.0 [-]
  • Time after engine start > 0.0 s
  • Rough road n.a.
  • And
  • Depending on gear:
  • 1st gear not active
  • 2nd gear not active
  • 3rd gear not active
  • 4th gear active
  • 5th gear active
  • 6th gear active
  • 7th gear active
  • 8th gear active
  • And
  • Integrated MAF >= 1.0 - 5.0 kg
  • Diff. engine speed vs. dynamic engine speed < 75 RPM
  • Diff. MAF vs. dynamic MAF < 29.99 mg/stk
  • ECT @ cylinder head 60 - 143° C
  • Adaptation cycles <= 3.0 [-]
  • Depending on transmission type:
  • For AT
  • Engine speed 1, 408 - 3, 008 RPM
  • For MT
  • Engine speed 1, 408 - 3, 008 RPM
  • For DCT
  • Engine speed 1, 408 - 3, 008 RPM
  • And
  • Mass fuel flow lower range >= 12.0 mg/stk
  • Mass fuel flow upper range <= 29.99 mg/stk
  • 90.0 s
  • Once / DCY
  • 2 DCY
-- Check the Fuel Injectors --. Refer to Fuel Injectors --, CHECKING .
Air Fuel Imbalance Monitoring Out Of Range Low Cyl. 1
  • Weighted adaptive value < -15.0%
P219D Cylinder 2 Air-Fuel Ratio Imbalance Air Fuel Imbalance Monitoring Out Of Range High Cyl. 2
  • Weighted adaptive value > 15.0%
  • Modeled catalyst temperature @ start <= 900° C
  • Lambda set value 0.97 - 1.03 [-]
  • Catalyst heating not active
  • Engine roughness signal valid
  • Cylinder shut off not active
  • AAT >= -48° C
  • Barometric pressure >= 73.0 kPa
  • And
  • Choice of: catalyst diagnosis n.a.
  • Or
  • Catalyst diagnosis n.a.
  • Depending on catalyst diagnosis:
  • Canister purge (conditions) n.a.
  • Or
  • Evap purge valve n.a.
  • Or
  • Evap purge n.a.
  • And
  • O2S dynamic diagnosis n.a.
  • O2S delay diagnosis n.a.
  • Lambda control closed loop
  • Catalyst purge not active
  • Canister load <= 2.0 [-]
  • Engine no full load
  • Fuel cut off not active
  • Segment adaptation finished
  • Catalyst damaging misfire not detected
  • Emission threshold misfire not detected
  • No gear switch for segments >= 90.0 [-]
  • Segments after start > 0.0 [-]
  • Time after engine start > 0.0 s
  • Rough road n.a.
  • And
  • Depending on gear:
  • 1st gear not active
  • 2nd gear not active
  • 3rd gear not active
  • 4th gear active
  • 5th gear active
  • 6th gear active
  • 7th gear active
  • 8th gear active
  • And
  • Integrated MAF >= 1.0 - 5.0 kg
  • Diff. engine speed vs. dynamic engine speed < 75 RPM
  • Diff. MAF vs. dynamic MAF < 29.99 mg/stk
  • ECT @ cylinder head 60 - 143° C
  • Adaptation cycles <= 3.0 [-]
  • Depending on transmission type:
  • For AT
  • Engine speed 1, 408 - 3, 008 RPM
  • For MT
  • Engine speed 1, 408 - 3, 008 RPM
  • For DCT
  • Engine speed 1, 408 - 3, 008 RPM
  • And
  • Mass fuel flow lower range >= 12.0 mg/stk
  • Mass fuel flow upper range <= 29.99 mg/stk
  • 90.0 s
  • Once / DCY
  • 2 DCY
-- Check the Fuel Injectors --. Refer to Fuel Injectors --, CHECKING .
Air Fuel Imbalance Monitoring Out Of Range Low Cyl. 2
  • Weighted adaptive value < -15.0%
P219E Cylinder 3 Air-Fuel Ratio Imbalance Air Fuel Imbalance Monitoring Out Of Range High Cyl. 3
  • Weighted adaptive value > 15.0%
  • Modeled catalyst temperature @ start <= 900° C
  • Lambda set value 0.97 - 1.03 [-]
  • Catalyst heating not active
  • Engine roughness signal valid
  • Cylinder shut off not active
  • AAT >= -48° C
  • Barometric pressure >= 73.0 kPa
  • And
  • Choice of: catalyst diagnosis n.a.
  • Or
  • Catalyst diagnosis n.a.
  • Depending on catalyst diagnosis:
  • Canister purge (conditions) n.a.
  • Or
  • Evap purge valve n.a.
  • Or
  • Evap purge n.a.
  • And
  • O2S dynamic diagnosis n.a.
  • O2S delay diagnosis n.a.
  • Lambda control closed loop
  • Catalyst purge not active
  • Canister load <= 2.0 [-]
  • Engine no full load
  • Fuel cut off not active
  • Segment adaptation finished
  • Catalyst damaging misfire not detected
  • Emission threshold misfire not detected
  • No gear switch for segments >= 90.0 [-]
  • Segments after start > 0.0 [-]
  • Time after engine start > 0.0 s
  • Rough road n.a.
  • And
  • Depending on gear:
  • 1st gear not active
  • 2nd gear not active
  • 3rd gear not active
  • 4th gear active
  • 5th gear active
  • 6th gear active
  • 7th gear active
  • 8th gear active
  • And
  • Integrated MAF >= 1.0 - 5.0 kg
  • Diff. engine speed vs. dynamic engine speed < 75 RPM
  • Diff. MAF vs. dynamic MAF < 29.99 mg/stk
  • ECT @ cylinder head 60 - 143° C
  • Adaptation cycles <= 3.0 [-]
  • Depending on transmission type:
  • For AT
  • Engine speed 1, 408 - 3, 008 RPM
  • For MT
  • Engine speed 1, 408 - 3, 008 RPM
  • For DCT
  • Engine speed 1, 408 - 3, 008 RPM
  • And
  • Mass fuel flow lower range >= 12.0 mg/stk
  • Mass fuel flow upper range <= 29.99 mg/stk
  • 90.0 s
  • Once / DCY
  • 2 DCY
-- Check the Fuel Injectors --. Refer to Fuel Injectors --, CHECKING .
Air Fuel Imbalance Monitoring Out Of Range Low Cyl. 3
  • Weighted adaptive value < -15.0%
P219F Cylinder 4 Air-Fuel Ratio Imbalance Air Fuel Imbalance Monitoring Out Of Range High Cyl. 4
  • Weighted adaptive value > 15.0%
  • Modeled catalyst temperature @ start <= 900° C
  • Lambda set value 0.97 - 1.03 [-]
  • Catalyst heating not active
  • Engine roughness signal valid
  • Cylinder shut off not active
  • AAT >= -48° C
  • Barometric pressure >= 73.0 kPa
  • And
  • Choice of: catalyst diagnosis n.a.
  • Or
  • Catalyst diagnosis n.a.
  • Depending on catalyst diagnosis:
  • Canister purge (conditions) n.a.
  • Or
  • Evap purge valve n.a.
  • Or
  • Evap purge n.a.
  • And
  • O2S dynamic diagnosis n.a.
  • O2S delay diagnosis n.a.
  • Lambda control closed loop
  • Catalyst purge not active
  • Canister load <= 2.0 [-]
  • Engine no full load
  • Fuel cut off not active
  • Segment adaptation finished
  • Catalyst damaging misfire not detected
  • Emission threshold misfire not detected
  • No gear switch for segments >= 90.0 [-]
  • Segments after start > 0.0 [-]
  • Time after engine start > 0.0 s
  • Rough road n.a.
  • And
  • Depending on gear:
  • 1st gear not active
  • 2nd gear not active
  • 3rd gear not active
  • 4th gear active
  • 5th gear active
  • 6th gear active
  • 7th gear active
  • 8th gear active
  • And
  • Integrated MAF >= 1.0 - 5.0 kg
  • Diff. engine speed vs. dynamic engine speed < 75 RPM
  • Diff. MAF vs. dynamic MAF < 29.99 mg/stk
  • ECT @ cylinder head 60 - 143° C
  • Adaptation cycles <= 3.0 [-]
  • Depending on transmission type:
  • For AT
  • Engine speed 1, 408 - 3, 008 RPM
  • For MT
  • Engine speed 1, 408 - 3, 008 RPM
  • For DCT
  • Engine speed 1, 408 - 3, 008 RPM
  • And
  • Mass fuel flow lower range >= 12.0 mg/stk
  • Mass fuel flow upper range <= 29.99 mg/stk
  • 90.0 s
  • Once / DCY
  • 2 DCY
-- Check the Fuel Injectors --. Refer to Fuel Injectors --, CHECKING .
Air Fuel Imbalance Monitoring Out Of Range Low Cyl. 4
  • Weighted adaptive value < -15.0%
P2237 O2 Sensor Positive Current Control Circuit/Open Bank 1 Sensor 1 Oxygen Sensors Front Open Circuit Pump Voltage (VIP)
  • Diff. pump voltage (VIP) vs. virtual ground voltage (VG) <= 1.20 V
  • Diff. nernst voltage (VN) vs. virtual ground voltage (VG) <= 1.20 V
  • And
  • Choice of:
  • Nernst voltage (VN) > 4.40 V
  • Or
  • Diff. pump voltage (VIP) vs. virtual ground voltage (VG) > 2.35 V
  • Diff. pump voltage (VIP) vs. virtual ground voltage (VG) < -2.35 V
  • Or
  • Diff. nernst voltage (VN) vs. virtual ground voltage (VG) > 1.60 V
  • Diff. nernst voltage (VN) vs. virtual ground voltage (VG) < -0.10 V
  • Or
  • Pump current > 0.0115 A
  • Or
  • Measurement WRAF sensor label resistor > n.a. Ω
  • O2S front (linear) ready
  • Measurement of WRAF sensor label resistor finished
  • Pump current controller active
  • 2.3 s
  • Continuous
  • 2 DCY
-- Check the Oxygen Sensor 1 Before Catalytic Converter -GX10-. Refer to Oxygen Sensor 1 Before Catalytic Converter - GX10-, CHECKING .
P2243 O2 Sensor Reference Voltage Circuit/Open Bank 1 Sensor 1 Oxygen Sensors Front Open Circuit Nernst Voltage (VN)
  • Diff. pump voltage (VIP) vs. virtual ground voltage (VG) <= 1.20 V
  • Diff. nernst voltage (VN) vs. virtual ground voltage (VG) <= 1.20 V
  • And
  • Choice of:
  • Nernst voltage (VN) > 4.40 V
  • Or
  • Diff. pump voltage (VIP) vs. virtual ground voltage (VG) > 2.35 V
  • Diff. pump voltage (VIP) vs. virtual ground voltage (VG) < -2.35 V
  • Or
  • Diff. nernst voltage (VN) vs. virtual ground voltage (VG) > 1.60 V
  • Diff. nernst voltage (VN) vs. virtual ground voltage (VG) < -0.10 V
  • Or
  • Pump current > 0.0115 A
  • Or
  • Measurement WRAF sensor label resistor > n.a. Ω
  • O2S front (linear) ready
  • Measurement of WRAF sensor label resistor finished
  • Pump current controller active
  • 2.3 s
  • Continuous
  • 2 DCY
-- Check the Oxygen Sensor 1 Before Catalytic Converter -GX10-. Refer to Oxygen Sensor 1 Before Catalytic Converter - GX10-, CHECKING .
P2251 O2 Sensor Negative Current Control Circuit/Open Bank 1 Sensor 1 Oxygen Sensors Front Open Circuit Virtual Ground (VG)
  • Nernst voltage (VN) > 4.40 V
  • Or
  • Diff. pump voltage (VIP) vs. virtual ground voltage (VG) > 2.35 V
  • Diff. pump voltage (VIP) vs. virtual ground voltage (VG) < -2.35 V
  • Or
  • Diff. nernst voltage (VN) vs. virtual ground voltage (VG) > 1.60 V
  • Diff. nernst voltage (VN) vs. virtual ground voltage (VG) < -0.10 V
  • Or
  • Pump current > 0.0115 A
  • Or
  • Measurement WRAF sensor label resistor > n.a. Ω
  • And
  • Choice of:
  • Diff. pump voltage (VIP) vs. virtual ground voltage (VG) <= 1.20 V
  • Diff. nernst voltage (VN) vs. virtual ground voltage (VG) <= 1.20 V
  • O2S front (linear) ready
  • Measurement of WRAF sensor label resistor finished
  • Pump current controller active
  • 2.3 s
  • Continuous
  • 2 DCY
-- Check the Oxygen Sensor 1 Before Catalytic Converter -GX10-. Refer to Oxygen Sensor 1 Before Catalytic Converter - GX10-, CHECKING .
P2257 Secondary Air Injection System Control "A" Circuit Low Secondary Air Injection Pump Relay Short To Ground
  • Output voltage, lower range 1.92 - 2.21 V
  • Output voltage, upper range (hardware values) <= 2.85 - 3.25 V
  • Engine running
  • Actuator commanded off
  • 1.0 s
  • Continuous
  • 2 DCY
-- Check the Secondary Air Injection Pump Relay -J299- / Secondary Air Injection Pump Motor -V101-. Refer to Secondary Air Injection Pump Relay - J299- / Secondary Air Injection Pump Motor - V101-, CHECKING .
P2258 Secondary Air Injection System Control "A" Circuit High Secondary Air Injection Pump Relay Short To Battery Voltage
  • Actuator temperature > 160 - 200° C
  • Or
  • Output current (hardware values) > 1.0 - 2.0 A
  • Engine running
  • Actuator commanded on
  • 1.0 s
  • Continuous
  • 2 DCY
-- Check the Secondary Air Injection Pump Relay -J299- / Secondary Air Injection Pump Motor -V101-. Refer to Secondary Air Injection Pump Relay - J299- / Secondary Air Injection Pump Motor - V101-, CHECKING .
P2270  HO2 Sensor Signal Stuck Lean Bank 1 Sensor 2 Oxygen Sensors Rear Signal Range Check
  • Max. O2S rear voltage < 0.87 V
  • General conditions:
  • Close the gap stimulation request active
  • Vehicle speed >= 6 mph
  • Catalyst overheating protection not active
  • Turbine overheating protection not active
  • O2S rear ready
  • O2S front ready
  • ECT @ cylinder head > 60° C
  • Modeled catalyst temperature 470 - 780° C
  • Difference between dynamic and stationary catalyst temperature -306 - 304° C
  • Modeled catalyst temperature once after engine start > 550° C
  • Integrated MAF, catalyst temp. conditions fulfilled >= 0.0 g
  • Modeled EGT @ O2S rear <= 900° C
  • MAF per cylinder 30.0 - 200.0 kg/h
  • MAF per cylinder per stroke, lower range >= 89.99 mg/stk
  • MAF per cylinder per stroke, upper range <= 750.0 mg/stk
  • And
  • Low dynamic conditions deviation actual
  • And
  • Target engine speed < 150 RPM
  • Dynamic MAF < 15.01 mg/stk
  • Dynamic lambda controller output <= 20.0%
  • And
  • Integrated MAF after dynamic conditions are fulfilled > 20.0 g
  • Time after a catalyst purge phase >= 1.0 s
  • O2S rear voltage @ diagnosis start >= 0.55 V
  • Integrated MAF to start diagnosis >= 5.0 g
  • Integrated heat energy >= 800.0 - 2, 000.0 kJ
  • Engine speed 1, 248 - 3, 008 RPM
  • Coasting function n.a O2S
  • Heater rear active
  • Lambda adaptation not active
  • Valve lift n.a.
  • And
  • Depending on Lambda control:
  • Intervention of trim control behavior activation of catalyst diagnosis < | 0.10 | [-]
  • Or
  • Intervention of trim control during active catalyst diagnosis < | 0.20 | [-]
  • Depending on canister purge:
  • Canister load <= n.a. [-]
  • Evap purge flow n.a.
  • Or
  • Canister load calculation n.a.
  • Evap purge flow n.a.
  • Or
  • Evap purge valve n.a
  • Depending on canister purge closing:
  • Canister purge (conditions) n.a.
  • Canister purge valve (closing time) n.a.
  • And
  • Choice of:
  • Evap purge valve n.a.
  • Or
  • Evap purge valve n.a.
  • And
  • Modeled MAF-integral > 0.0 g
  • Depending on transmission type:
  • For MT
  • Integrated MAF per cylinder >= 0.0 kg
  • For AT
  • Integrated MAF per cylinder >= 0.0 kg
  • For DCT
  • Integrated MAF per cylinder >= 0.0 kg
  • 60.0 - 70.0 s
  • Once / DCY
  • 2 DCY
-- Check the Oxygen Sensor 1 After Catalytic Converter -GX7-. Refer to Oxygen Sensor 1 After Catalytic Converter - GX7-, CHECKING .
P2271  O2 Sensor Signal Stuck Rich Bank 1 Sensor 2 Oxygen Sensors Rear Signal Range Check
  • Max. O2S rear voltage > 0.87 V
  • General conditions:
  • Close the gap stimulation request active
  • Vehicle speed >= 6 mph
  • Catalyst overheating protection not active
  • Turbine overheating protection not active
  • O2S rear ready
  • O2S front ready
  • ECT @ cylinder head > 60° C
  • Modeled catalyst temperature 470 - 780° C
  • Difference between dynamic and stationary catalyst temperature -306 - 304° C
  • Modeled catalyst temperature once after engine start > 550° C
  • Integrated MAF, catalyst temp. conditions fulfilled >= 0.0 g
  • Modeled EGT @ O2S rear <= 900° C
  • MAF per cylinder 30.0 - 200.0 kg/h
  • MAF per cylinder per stroke, lower range >= 89.99 mg/stk
  • MAF per cylinder per stroke, upper range <= 750.0 mg/stk
  • And
  • Low dynamic conditions deviation actual
  • And
  • Target engine speed < 150 RPM
  • Dynamic MAF < 15.01 mg/stk
  • Dynamic lambda controller output <= 20.0%
  • And
  • Integrated MAF after dynamic conditions are fulfilled > 20.0 g
  • Time after a catalyst purge phase >= 1.0 s
  • O2S rear voltage @ diagnosis start >= 0.55 V
  • Integrated MAF to start diagnosis >= 5.0 g
  • Integrated heat energy >= 800.0 - 2, 000.0 kJ
  • Engine speed 1, 248 - 3, 008 RPM
  • Coasting function n.a O2S
  • Heater rear active
  • Lambda adaptation not active
  • Valve lift n.a.
  • And
  • Depending on Lambda control:
  • Intervention of trim control behavior activation of catalyst diagnosis < | 0.10 | [-]
  • Or
  • Intervention of trim control during active catalyst diagnosis < | 0.20 | [-]
  • Depending on canister purge:
  • Canister load <= n.a. [-]
  • Evap purge flow n.a.
  • Or
  • Canister load calculation n.a.
  • Evap purge flow n.a.
  • Or
  • Evap purge valve n.a
  • Depending on canister purge closing:
  • Canister purge (conditions) n.a.
  • Canister purge valve (closing time) n.a.
  • And
  • Choice of:
  • Evap purge valve n.a.
  • Or
  • Evap purge valve n.a.
  • And
  • Modeled MAF-integral > 0.0 g
  • Depending on transmission type:
  • For MT
  • Integrated MAF per cylinder >= 0.0 kg
  • For AT
  • Integrated MAF per cylinder >= 0.0 kg
  • For DCT
  • Integrated MAF per cylinder >= 0.0 kg
  • 60.0 - 70.0 s
  • Once / DCY
  • 2 DCY
-- Check the Oxygen Sensor 1 After Catalytic Converter -GX7-. Refer to Oxygen Sensor 1 After Catalytic Converter - GX7-, CHECKING .
P2279 Intake Air System Leak Intake Air System Rationality Check
  • General conditions:
  • Filtered lambda controller included correction and adaption -30.0 - 30.0%
  • Lambda control active
  • And
  • Deviation throttle area controller > 60.0%
  • Throttle position > 0.0° TPS
  • Throttle position < 100.003° TPS
  • Engine speed > 576; < 3, 008 RPM
  • Modeled pressure quotient > 0.27; < 0.60 [-]
  • Engine running throttle actuator commanded on time after engine start > 5.0 s
  • Throttle position sensor failure not detected
  • Fuel cut off not active
  • Fast throttle adaptation finished
  • Gradient intake manifold pressure -199.90 - 199.90 kPa/s
  • Engine speed limitation not active
  • Barometric pressure plausibility diagnosis finished
  • Intake manifold modeled adaption active
  • And
  • Choice of:
  • MAF sensor active
  • Or
  • Manifold pressure sensor active
  • And
  • Choice of:
  • Pressure upstream throttle < 135.0 kPa
  • Or
  • Pressure upstream throttle not active
  • And
  • Choice of:
  • Barometric pressure > 73.0; < 107.50 kPa
  • Or
  • Barometric pressure sensor not active
  • 5.0 s
  • Continuous
  • 2 DCY
-- Check for air leaks between intake and throttle body, oil fill cap not tight or oil dipstick not seated in tube. Refer to appropriate repair information.-- Also any engine gaskets that can cause additional air to enter the crankcase can set this fault as the PCV system is not metered. If a vacuum leak or crankcase gasket sealing is at cause, the idle may be rough or unstable. Refer to appropriate repair information.
P2294 Fuel Pressure Regulator 2 Control Circuit/Open Fuel Control Valve Open Circuit
  • Low and high side off:
  • Voltage low side > 2.78 - 3.33 V
  • Voltage high side < 1.87 - 2.26 V
  • Low and high side on:
  • Current low side < 12.2 - 15.0 A
  • Current high side < 13.5 - 16.5 A
  • Engine speed > 600 RPM
  • And
  • Fuel cut off not active
  • Actuator commanded on
  • 0.8 s
  • Continuous
  • 2 DCY
-- Check the Fuel Metering Valve -N290-. Refer to Fuel Metering Valve - N290-, CHECKING .
P2295 Fuel Pressure Regulator 2 Control Circuit Low Fuel Control Valve Short To Ground
  • Current high side (hardware values) > 13.4 - 17.0 A
  • Voltage low side (hardware values) < 1.92 - 2.10 V
  • Ignition on
  • Or
  • Ignition off (during ECM keep alive-time)
  • And
  • Actuator commanded off
  • 0.8 s
  • Continuous
  • 2 DCY
-- Check the Fuel Metering Valve -N290-. Refer to Fuel Metering Valve - N290-, CHECKING .
P2414 O2 Sensor Exhaust Sample Error Bank 1, Sensor 1 Oxygen Sensors Front Rationality Check
  • Pump current correction (nernst-cell) > 0.0 A
  • O2S front ready
  • Fuel cut off not active
  • Cylinder shut off not active
  • Depending on engine state:
  • Engine part load
  • Or
  • Engine full load
  • Or
  • Engine idle for time >= 5.0 s
  • 10.0 s
  • Continuous
  • 2 DCY
-- Check the Oxygen Sensor 1 Before Catalytic Converter -GX10-. Refer to Oxygen Sensor 1 Before Catalytic Converter - GX10-, CHECKING .
P2431 Secondary Air Injection System Air Flow/Pressure Sensor Circuit Range/Performance Secondary Air System Pressure Sensor Rationality Check
  • Difference between AIR pressure and barometric pressure > 6.0 kPa
  • And
  • Difference between AIR pressure and intake manifold pressure > 6.0 kPa
  • Engine stop for time > 0.0 s
  • 0.1 s
  • Once / DCY
  • 2 DCY
-- Check the Secondary Air System -GX24-. Refer to Secondary Air Injection Sensor 1 - G609-, CHECKING .
P2432 Secondary Air Injection System Air Flow/Pressure Sensor Circuit Low Secondary Air System Pressure Sensor Out Of Range Low
  • Sensor voltage < 0.50 V
 
  • 0.1 s
  • Once / DCY
  • 2 DCY
-- Check the Secondary Air System -GX24-. Refer to Secondary Air Injection Sensor 1 - G609-, CHECKING .
P2433 Secondary Air Injection System Air Flow/Pressure Sensor Circuit High Secondary Air System Pressure Sensor Out Of Range High
  • Sensor voltage > 4.50 V
 
  • 0.1 s
  • Once / DCY
  • 2 DCY
-- Check the Secondary Air System -GX24-. Refer to Secondary Air Injection Sensor 1 - G609-, CHECKING .
P2440  Secondary Air Injection System Switching Valve Stuck Open Secondary Air Valve Functional Check
  • Diff. pressure value after secondary air injection vs. pressure value before secondary air activation > 5.0 kPa
  • General:
  • Secondary air pump ready
  • Catalyst heating active
  • Secondary air injection finished
  • MAF <= 140.0 kg/h
  • ECT @ cylinder head >= -10; < 115° C
  • IAT @ manifold >= -10; < 100° C
  • Modeled catalyst temperature < 700° C
  • Relative barometric pressure > 0.73 [-]
  • And
  • Diff. barometric pressure vs. manifold pressure > n.a. kPa
  • 0.1 s
  • Once / DCY
  • 2 DCY
-- Check the Secondary Air Injection Solenoid Valve -N112-. Refer to Secondary Air Injection Solenoid Valve - N112-, CHECKING .
P2556 Engine Coolant Level Sensor / Switch Circuit Rotary Coolant Valve Checksum Verification
  • Communication signal failure
  • Sensor signal failure
 
  • 0.5 s
  • Continuous
  • 2 DCY
-- Check the Engine Temperature Control Actuator -N493-. Refer to Engine Temperature Control Actuator - N493-, CHECKING .
P2557 Engine Coolant Level Sensor/Switch Circuit Range / Performance Rotary Coolant Valve Signal Check & Communications Check
  • Checksum signal failure
 
  • 0.5 s
  • Continuous
  • 2 DCY
-- Check the Engine Temperature Control Actuator -N493-. Refer to Engine Temperature Control Actuator - N493-, CHECKING .
P2564 Turbocharger Boost Control Position Sensor "A" Circuit Low Turbocharger Boost Control Position Sensor Short To Ground
  • Turbocharger boost control position sensor voltage < 0.20 V
 
  • 0.5 s
  • Continuous
  • 2 DCY
-- Check the Charge Pressure Actuator Position Sensor -G581-. Refer to Charge Air Pressure Actuator - V465- / Charge Air Pressure Actuator Position Sensor - G581-, CHECKING ..
P2565 Turbocharger Boost Control Position Sensor "A" Circuit High Turbocharger Boost Control Position Sensor Short To Battery Voltage
  • Turbocharger boost control position sensor voltage > 4.80 V
 
  • 0.5 s
  • Continuous
  • 2 DCY
-- Check the Charge Pressure Actuator Position Sensor -G581-. Refer to Charge Air Pressure Actuator - V465- / Charge Air Pressure Actuator Position Sensor - G581-, CHECKING ..
P2610 ECM / PCM Internal Engine Off Timer Performance Engine off Time ECM Internal Timer Check
  • Case 1:
  • ECM internal timer initialization failure
  • Case 2:
  • ECM internal timer communication failure
  • ECM internal timer reset not active
  • SPI communication failure after reset not detected
  • 1.3 s
  • Continuous
  • 2 DCY
-- Check the Engine Control Module -J623-. Refer to appropriate repair information.
Rationality Check
  • Difference between engine-off-time and ECM keep alive-time >= 12.0 s
  • Or
  • Engine off time not valid (hardware values)
  • Choice of:
  • ECM keep alive-time active
  • ECU internal timer reset not activated
  • Time delay >= 1.0 s
  • Or
  • Delay timer for acquisition of engine-off-time (hardware values) > 1.0 s
  • Or
  • Result of low power check initialization > 0.0; < 9.0 [-]
  • Or
  • Time after engine stop < 86, 400.0 s
  • Engine off time plausible
  • Engine off time monitoring not finished
  • Engine off time signal valid time after reset < 2.0 s
  • And
  • Case 1:
  • Engine off timer n.a.
  • Or
  • Engine off time n.a.
  • Case 2:
  • ECM internal timer active
  • SPI communication failure after reset detected
  • 0.01 s
  • Once / DCY
P2681 Engine Coolant Bypass Valve Control Circuit/Open Rotary Coolant Valve Open Circuit
  • Load resistance > 200.0 kΩ
 
  • 1.5 s
  • Continuous
  • 2 DCY
-- Check the Engine Temperature Control Actuator -N493-. Refer to Engine Temperature Control Actuator - N493-, CHECKING ..
P2682 Engine Coolant Bypass Valve Control Circuit Low Rotary Coolant Valve Short To Ground
  • Short to ground output 1:
  • High side current output 1 > 9.3 - 15.0 A
  • Rotary slide valve commanded on
  • Rotary valve direction forward
  • 0.25 s
  • Continuous
  • 2 DCY
-- Check the Engine Temperature Control Actuator -N493-. Refer to Engine Temperature Control Actuator - N493-, CHECKING .
  • Short to ground output 2:
  • High side current output 2 > 9.3 - 15.0 A
  • Rotary slide valve commanded on
  • Rotary valve direction reserved
P2683 Engine Coolant Bypass Valve Control Circuit High Rotary Coolant Valve Short To Battery Voltage
  • Output 1:
  • Low side current output 1 > 9.3 - 15.0 A
  • Rotary slide valve commanded off
  • Or
  • Rotary slide valve commanded on
  • Rotary valve direction reverse
  • Or
  • 0.25 s
  • Continuous
  • 2 DCY
-- Check the Engine Temperature Control Actuator -N493-. Refer to Engine Temperature Control Actuator - N493-, CHECKING .
  • Output 2:
  • Low side current output 2 > 9.3 - 15.0 A
  • Rotary slide valve commanded off
  • Or
  • Rotary slide valve commanded on
  • Rotary valve direction forward
P3043 Fuel Pump Mechanical Malfunction CAN: Fuel Pump CAN Communication With Fuel Pump
  • Fuel pump signal: rotary failure feedback >= 2.0 [-]
  • Engine on
  • 1.8 s
  • Continuous
  • 2 DCY
-- Check the Fuel Delivery Unit -GX1- / Fuel Pump Control Module -J538-. Refer to Fuel Delivery Unit -GX1- / Fuel Pump Control Module -J538-, CHECKING .
P3044 Fuel Pump "A" Control Circuit Low CAN: Fuel Pump CAN Communication With Fuel Pump
  • Fuel pump sensor: short to ground failure feedback >= 2.0 [-]
  • Engine on
  • 2.0 s
  • Continuous
  • 2 DCY
-- Check the Fuel Delivery Unit -GX1- / Fuel Pump Control Module -J538-. Refer to Fuel Delivery Unit -GX1- / Fuel Pump Control Module -J538-, CHECKING .
P3045 Fuel Pump Electronics Faulty CAN: Fuel Pump CAN Communication With Fuel Pump
  • Fuel pump signal: ROM / RAM failure feedback >= 2.0 [-]
  • Engine on
  • 1.2 s
  • Continuous
  • 2 DCY
-- Check the Fuel Delivery Unit -GX1-. Refer to Fuel Delivery Unit -GX1- / Fuel Pump Control Module -J538-, CHECKING .-- Check the Engine Control Module -J623-. Refer to the repair information.
P3073 Fuel Pump "A" Control Circuit/Open CAN: Fuel Pump CAN Communication With Fuel Pump
  • Fuel pump sensor: open circuit failure feedback >= 2.0 [-]
  • Engine on
  • 2.2 s
  • Continuous
  • 2 DCY
-- Check the Fuel Delivery Unit -GX1- / Fuel Pump Control Module -J538-. Refer to Fuel Delivery Unit -GX1- / Fuel Pump Control Module -J538-, CHECKING .
P308D Fuel Pump "A" Low Flow/Performance CAN: Fuel Pump CAN Communication With Fuel Pump
  • Fuel pump signal: over-current failure feedback >= 2.0 [-]
  • Engine on
  • 1.6 s
  • Continuous
  • 2 DCY
-- Check the Fuel Delivery Unit -GX1- / Fuel Pump Control Module -J538-. Refer to Fuel Delivery Unit -GX1- / Fuel Pump Control Module -J538-, CHECKING .
P308E Fuel Pump Control Module "A" CAN: Fuel Pump CAN Communication With Fuel Pump
  • Fuel pump signal: power amplifier failure feedback >= 2.0 [-]
  • Engine on
  • 1.4 s
  • Continuous
  • 2 DCY
-- Check the Fuel Delivery Unit -GX1- / Fuel Pump Control Module -J538-. Refer to Fuel Delivery Unit -GX1- / Fuel Pump Control Module -J538-, CHECKING .
  • Fuel pump sensor:
  • Short to battery failure
  • Or
  • RPM deviation feedback >= 2.0 [-]
  • 2.4 s
  • Continuous
P334A Turbocharger/Supercharger Boost Control "A" Circuit/Open Turbocharger Boost Pressure Control Valve Open Circuit
  • Bypass valve driver current > 9.3 - 15.0 A
  • Boost pressure actuator controller active
  • 0.4 s
  • Continuous
  • 2 DCY
-- Check the Charge Air Pressure Actuator -V465- / Charge Air Pressure Actuator Position Sensor -G581-. Refer to Charge Air Pressure Actuator - V465- / Charge Air Pressure Actuator Position Sensor - G581-, CHECKING .
U0001 High Speed CAN Communication Bus CAN: Bus-Off CAN Communication
  • Bus off counter >= 3.0 [-]
  • Time after ignition on >= 0.5 s
  • 0.5 s
  • Continuous
  • 2 DCY
-- Check the CAN-Bus terminal resistance. Refer to CAN-BUS TERMINAL RESISTANCE, CHECKING .
U0002 High Speed CAN Communication Bus Performance CAN: Global Time Out CAN Communication
  • General CAN timeout >= 0.4 s
  • Time after ignition on >= 0.5 s
  • 0.5 s
  • Continuous
  • 2 DCY
-- Check the CAN-Bus terminal resistance. Refer to CAN-BUS TERMINAL RESISTANCE, CHECKING .
U0101 Lost Communication with TCM CAN: Transmission Control Module (TCM) CAN Communication With TCM
  • Received CAN message no message
  • Time after ignition on >= 0.5 s
  • 0.5 s
  • Continuous
  • 2 DCY
-- Check the CAN-Bus terminal resistance. Refer to CAN-BUS TERMINAL RESISTANCE, CHECKING .
U0121 Lost Communication With Anti-Lock Brake System (ABS) Control Module CAN: Brake System Control Module (BSCM) CAN Communication With Brake Unit
  • Received CAN message no message
  • Time after ignition on >= 0.5 s
  • 0.5 s
  • Continuous
  • 2 DCY
-- Check the CAN-Bus terminal resistance. Refer to CAN-BUS TERMINAL RESISTANCE, CHECKING .
U0140 Lost Communication With Body Control Module CAN: Body Control Module (BCM) CAN Communication With Body Control Module
  • Received CAN message no message
  • Time after ignition on >= 0.5 s
  • 0.5 s
  • Continuous
  • 2 DCY
-- Check the CAN-Bus terminal resistance. Refer to CAN-BUS TERMINAL RESISTANCE, CHECKING .
U0146 Lost Communication With Gateway "A" CAN: Gateway CAN Communication With Gateway
  • Received CAN message no message
  • Time after ignition on >= 0.5 s
  • 0.5 s
  • Continuous
  • 2 DCY
-- Check the CAN-Bus terminal resistance. Refer to CAN-BUS TERMINAL RESISTANCE, CHECKING .
U0155 Lost Communication With Instrument Panel Cluster Control Module CAN: Instrument Cluster CAN Communication With Instrument Cluster Module
  • Received CAN message no message
  • Time after ignition on >= 0.5 s
  • 0.5 s
  • Continuous
  • 2 DCY
-- Check the CAN-Bus terminal resistance. Refer to CAN-BUS TERMINAL RESISTANCE, CHECKING .
U0302 Software Incompatibility with Transmission Control Module ECM: Coding Code Check Of ECM Concerning TCM
  • Received AT vehicle data from TCM, TCM signal
  • Time after ignition on 500.0 ms
  • 50.0 s
  • Continuous
  • 2 DCY
-- Check for software updates and TSB's. Reprogram as necessary. If none are found, refer to the Repair information.
U0322 Software Incompatibility With Body Control Module CAN: Gateway CAN Communication With Gateway
  • ambient temperature sensor coding monitoring failure
  • Time after ignition on > 1.5 s
  • 2.0 s
  • Continuous
  • 2 DCY
-- Check the CAN-Bus terminal resistance. Refer to CAN-BUS TERMINAL RESISTANCE, CHECKING .
U0402 Invalid Data Received From Gear Shift Control Module A CAN: Transmission Control Module (TCM) CAN Communication With TCM
  • Received data from TCS implausible message
  • Time since engine on > 0.5 s
  • 0.5 s
  • Continuous
  • 2 DCY
-- Check the CAN-Bus terminal resistance. Refer to CAN-BUS TERMINAL RESISTANCE, CHECKING .
U0415 CAN Communication With ABS Error Vehicle Speed Rationality Check High
  • Vehicle speed > 202 mph
  • Speed sensor signal:
  • Sensor error 407 mph
  • Initialization error 407 mph
  • Low voltage error 407 mph
  • Time since engine on > 0.5 s
  • 0.5 - 4.0 s
  • Continuous
  • 2 DCY
-- Check the CAN-Bus terminal resistance. Refer to CAN-BUS TERMINAL RESISTANCE, CHECKING .
CAN: Brake System Control Module (BSCM) CAN Communication With Brake Unit
  • Received data from TCS implausible message
  • Time since engine on > 0.5 s
U0422 Invalid Data Received From Body Control Module CAN: Gateway CAN Communication With Gateway
  • Ambient temperature value (initialization) failure
  • Time after ignition on > 1.5 s
  • Engine running
  • 3.0 s
  • Continuous
  • 2 DCY
-- Check the Outside Air Temperature Sensor -G17-. Refer to Outside Air Temperature Sensor - G17-, CHECKING .-- Check the CAN-Bus terminal resistance. Refer to CAN-BUS TERMINAL RESISTANCE, CHECKING .
U0423 Invalid Data Received From Instrument Panel Cluster Control Module CAN: Instrument Cluster CAN Communication With Instrument Cluster Module
  • Received data from Instrument Cluster implausible message
  • Time after ignition on >= 0.5 s
  • 0.5 - 3.0 s
  • Continuous
  • 2 DCY
-- Check the CAN-Bus terminal resistance. Refer to CAN-BUS TERMINAL RESISTANCE, CHECKING .
U0447 Invalid Data Received From Gateway "A" CAN: Gateway CAN Communication With Gateway
  • Received data from Gateway implausible message
  • Time after ignition on >= 0.5 s
  • 0.5 s
  • Continuous
  • 2 DCY
-- Check the CAN-Bus terminal resistance. Refer to CAN-BUS TERMINAL RESISTANCE, CHECKING .
U1103 Production Mode Active ECM: Production Mode Function Monitoring: Mode Change
  • Production mode active
  • Vehicle speed < 3 mph
  • Max trip mileage since initial vehicle start-up < 62.15 miles
  • During ECM keep alive-time after ignition off engine speed 0 RPM
  • Production mode not active
  • For hybrid:
  • Drive motor off
  • 0.01 s
  • Continuous
  • 1 DCY
-- Vehicle in production mode. Refer to appropriate repair information for resolution. Note the mode can be deactivated with a factory scan tool or will automatically turn off after vehicle accumulates the first 100 km (62.14 miles) of driving.