Peripheral Camera, Calibrating

WARNING: This page is about a different car, the 2022 Audi Q3. However, it is still accessible from the selected car via links, so may be relevant.

Special tools and workshop equipment required 

Calibration/Adjustment must be Performed if:

Preparing for Calibration

GWWA91-12469Courtesy of AUDI OF AMERICA, LLC
  1. Left Calibration Field
  2. Front Peripheral Camera -R243-
  3. Right Calibration Field
  4. Right Peripheral Camera -R245-
  5. Rear Peripheral Camera -R246-
  6. Left Peripheral Camera -R244-

Requirements

GWWA91-12470Courtesy of AUDI OF AMERICA, LLC

Procedure 

-- Left and right calibration field near the vehicle.

-- Apply the rear and front clamping strips on the calibration field.

-- Align the crosshairs -2- on the calibration field to the front axle of the vehicle (front wheel center).

-- Align both calibration fields parallel. The vehicle must be located in the center between both calibration fields.

Pay attention to the following measurement requirements:

Calibration Procedure

The following should not occur during the calibration procedure:

-- Connect the Vehicle Diagnostic Tester.

-- Switch the ignition on.

-- Select and start the Diagnostic  operating mode.

-- Select the Test plan  tab.

-- Select the Select individual test  button and select the following tree structure consecutively:

-- Start the selected program and follow the instructions on the Vehicle Diagnostic Tester display.

-- Switch off the ignition after successful calibration/adjustment.

-- Disconnect the Vehicle Diagnostic Tester from the data link connector.

-- Disconnect the battery charger. Refer to BATTERY, CHARGING .