DCDC Converter Control Module (DCDC) --, 2024 MY
WARNING: This page is about a different car, the 2024 Audi S6 and 2024 Audi A6 Quattro. However, it is still accessible from the selected car via links, so may be relevant.
| Monitor / System | DTC / DTC Description | Monitor Strategy Description | Malfunction Criteria | Threshold Value | Secondary Parameters | Enable Condition | Monitoring Time Length | MIL Illum. | ||
|---|---|---|---|---|---|---|---|---|---|---|
| Micro controller supply Voltage Sensor U_Terminal 30 | P0A08 - DC/DC Converter Status Circuit | Short to ground | Measured voltage | < 1.0 | [V] | Terminal 30 | ON | 100 ms continuous | Immediately | |
| Out of range low | Measured voltage | < 3.0 | [V] | Terminal 30 | ON | 100 ms continuous | Immediately | |||
| Out of range high | Measured voltage | > 32.0 | [V] | Terminal 30 | ON | 100 ms continuous | Immediately | |||
| P0A94 - DC/DC Converter "A" Performance | Rationality low : Plausible check with other sensor measurement US1_1 | Input voltage difference between measurements at main micro controller and safety micro controller | < -1.0 | [V] | Safety switch S1 Functional Safety (FUSI) | Closed Enabled | 100 ms continuous | 2 DCY | ||
| Rationality high : Plausible check with other sensor measurement US1_1 | Input voltage difference between measurements at main micro controller and safety micro controller | > 1.0 | [V] | Safety switch S1 Functional Safety (FUSI) | Closed Enabled | 100 ms continuous | 2 DCY | |||
| 48V supply Voltage Sensor U_Terminal 40 | Short to ground | Measured voltage | < 1.0 | [V] | Safety switch S1 Functional Safety (FUSI) | Closed Enabled | 100 ms continuous | 2 DCY | ||
| Out of range low | Measured voltage | < 3.0 | [V] | Safety switch S1 Functional Safety (FUSI) | Closed Enabled | 100 ms continuous | 2 DCY | |||
| Out of range high | Measured voltage | > 63.0 | [V] | Terminal 30 | ON | 100 ms continuous | 2 DCY | |||
| Other rationality : Plausible check with modelled value | Differential voltage between measured and modelled value | < -30 > 30 | [V] [V] | I_Terminal 30 Terminal 30_Voltage | ≥ 8 > 9 | [A] [V] | 100 ms continuous | 2 DCY | ||
| Safety switch 1_1 input supply Voltage Sensor U_Safety switch1_1 | Short to ground | Measured voltage | < 1.0 | [V] | Safety switch S1 Functional Safety (FUSI) | Closed Enabled | 100 ms continuous | 2 DCY | ||
| Out of range low | Measured voltage | < 3.0 | [V] | Safety switch S1 Functional Safety (FUSI) | Closed Enabled | 100 ms continuous | 2 DCY | |||
| Out of range high | Measured voltage | > 32.0 | [V] | Terminal 30 | ON | 100 ms continuous | 2 DCY | |||
| Rationality low : Plausible check with other sensor measurement US1_2 | Input voltage difference between measurements at Safety switch S1_1 and Safety switch S1_2 | < -1.0 | [V] | Terminal 30 | ON | 100 ms continuous | 2 DCY | |||
| Rationality high : Plausible check with other sensor measurement US1_2 | Input voltage difference between measurements at Safety switch S1_1 and Safety switch S1_2 | > 1.0 | [V] | Terminal 30 | ON | 100 ms continuous | 2 DCY | |||
| Safety switch1_2 input supply Voltage Sensor U_Safety switch1_2 | Short to ground | Measured voltage | < 1.0 | [V] | Safety switch S1 Functional Safety (FUSI) | Closed Enabled | 100 ms continuous | 2 DCY | ||
| Out of range low | Measured voltage | < 3.0 | [V] | Safety switch S1 Functional Safety (FUSI) | Closed Enabled | 100 ms continuous | 2 DCY | |||
| Out of range high | Measured voltage | > 32.0 | [V] | Terminal 30 | ON | 100 ms continuous | 2 DCY | |||
| Rationality low : Plausible check with other sensor measurement US1_3 | Input voltage difference between measurements at Safety switch S1_2 and Safety switch S1_3 | < -1.0 | [V] | Terminal 30 | ON | 100 ms continuous | 2 DCY | |||
| Rationality high : Plausible check with other sensor measurement US1_3 | Input voltage difference between measurements at Safety switch S1_2 and Safety switch S1_3 | > 1.0 | [V] | Terminal 30 | ON | 100 ms continuous | 2 DCY | |||
| Safety switch1_3 input supply Voltage Sensor U_Safety switch1_3 | Short to ground | Measured voltage | < 1.0 | [V] | Safety switch S1 Functional Safety (FUSI) | Closed Enabled | 100 ms continuous | 2 DCY | ||
| Out of range low | Measured voltage | < 3.0 | [V] | Safety switch S1 Functional Safety (FUSI) | Closed Enabled | 100 ms continuous | 2 DCY | |||
| Out of range high | Measured voltage | > 32.0 | [V] | Terminal 30 | ON | 100 ms continuous | 2 DCY | |||
| Rationality low : Plausible check with other sensor measurement US1_4 | Input voltage difference between measurements at Safety switch S1_3 and Safety switch S1_4 | < -1.0 | [V] | Terminal 30 | ON | 100 ms continuous | 2 DCY | |||
| Rationality high : Plausible check with other sensor measurement US1_4 | Input voltage difference between measurements at Safety switch S1_3 and Safety switch S1_4 | > 1.0 | [V] | Terminal 30 | ON | 100 ms continuous | 2 DCY | |||
| Safety switch1_4 input supply Voltage Sensor U_Safety switch1_4 | Short to ground | Measured voltage | < 1.0 | [V] | Safety switch S1 Functional Safety (FUSI) | Closed Enabled | 100 ms continuous | 2 DCY | ||
| Out of range low | Measured voltage | < 3.0 | [V] | Safety switch S1 Functional Safety (FUSI) | Closed Enabled | 100 ms continuous | 2 DCY | |||
| Out of range high | Measured voltage | > 32.0 | [V] | Terminal 30 | ON | 100 ms continuous | 2 DCY | |||
| Rationality low : Plausible check with other sensor measurement US1_1 | Input voltage difference between measurements at Safety switch S1_4 and Safety switch S1_1 | < -1.0 | [V] | Terminal 30 | ON | 100 ms continuous | 2 DCY | |||
| Rationality high : Plausible check with other sensor measurement US1_1 | Input voltage difference between measurements at Safety switch S1_4 and Safety switch S1_1 | > 1.0 | [V] | Terminal 30 | ON | 100 ms continuous | 2 DCY | |||
| 11V actuator supply check Voltage Sensor - main uC | P0A08 - DC/DC Converter Status Circuit | Rationality check : Verification with limit values | Measured voltage | ≤ 10.5 ≥ 15.0 | [V] | U_Terminal 30 | > 4.5 | [V] | 100 ms continuous | Immediately |
| 11V actuator supply check Voltage Sensor - Safety uC | Rationality check : Verification with limit values | Measured voltage | ≤ 10.5 ≥ 15.0 | [V] | Safety controller communication U_Terminal 30 | ON > 4.5 | [-] [V] | 100 ms continuous | Immediately | |
| Capacitor input voltage U_PUMP_S1 | Rationality check : Plausibility check with other sensor measurement | Difference between measurements at capacitor and main micro controller Terminal_30 | ≤ 8.0 ≥15.0 | [V] [V] | U_Terminal 30 | ≤ U_Pump_S 1 (and) > 4.5 | [V] [V] | 100 ms continuous | Immediately | |
| Short to ground | Measured voltage | < 1.0 | [V] | Safety controller communication | Active | 100 ms continuous | Immediately | |||
| Out of range low | Measured voltage | < 3.0 | [V] | Safety controller communication | Active | 100 ms continuous | Immediately | |||
| Out of range high | Measured voltage | > 32.0 | [V] | Safety controller communication | Active | 100 ms continuous | Immediately | |||
| Safety Microcontroller supply Voltage Sensor US1_safety_uC | P0A94 - DC/DC Converter "A" Performance | Rationality low : Plausible check with other sensor measurement US1_1 | Input voltage difference between measurements at Safety micro controller and Safety switch S1_1 | < -1.0 | [V] | Safety switch S1 Safety controller communication | Closed Active | 100 ms continuous | 2 DCY | |
| Rationality high : Plausible check with other sensor measurement US1_1 | Input voltage difference between measurements at Safety micro controller and Safety switch S1_1 | > 1.0 | [V] | Safety switch S1 Safety controller communication | Closed Active | 100 ms continuous | 2 DCY | |||
| Temperature Sensor absolute value t1°C converted value t1 digits | P0A08 - DC/DC Converter Status Circuit | Other Rationality - Erratic intermittent contact check by temperature rate of change | Calculated rate of change of measured temperature t1 with time | > 2.0 | [°C / s] | Terminal 30 | ON | 100 ms continuous | Immediately | |
| Out of range low | Measured temperature | < 200 | [Digit s] | Terminal 30 | ON | 100 ms continuous | Immediately | |||
| Out of range high | Measured temperature | > 4090 | [Digit s] | Terminal 30 | ON | 100 ms continuous | Immediately | |||
| P0A94 - DC/DC Converter "A" Performance | Rationality low : Plausible check with other sensor measurement | Temperature difference between measurements at sensor t1 and t2 | < -400 | [Digit s] | Terminal 30 | ON | 100 ms continuous | 2 DCY | ||
| Rationality high : Plausible check with other sensor measurement | Temperature difference between measurements at sensor t1 and t2 | >400 | [Digit s] | Terminal 30 | ON | 100 ms continuous | 2 DCY | |||
| Temperature Sensor absolute value t2°C converted value t2 digits | P0A08 - DC/DC Converter Status Circuit | Other Rationality - Erratic intermittent contact check using rate of change temperature | Calculated rate of change of temperature measurement t2 with time | > 2.0 | [°C / s] | Terminal 30 | ON | 100 ms continuous | Immediately | |
| Out of range low | Measured temperature | < 200 | [Digit s] | Terminal 30 | ON | 100 ms continuous | Immediately | |||
| Out of range high | Measured temperature | > 4090 | [Digit s] | Terminal 30 | ON | 100 ms continuous | Immediately | |||
| P0A94 - DC/DC Converter "A" Performance | Rationality low : Plausible check with other sensor measurement | Temperature difference between measurements at sensor t2 and t3 | < -400 | [Digit s] | Terminal 30 | ON | 100 ms continuous | 2 DCY | ||
| Rationaility high : Plausible check with other sensor measurement | Temperature difference between measurements at sensor t2 and t3 | >400 | [Digit s] | Terminal 30 | ON | 100 ms continuous | 2 DCY | |||
| Temperature Sensor absolute value t3°C converted value t3 digits | P0A08 - DC/DC Converter Status Circuit | Other Rationality - Erratic intermittent contact check using rate of change temperature | Calculated rate of change of temperature measurement t3 with time | > 2.0 | [°C / s] | Terminal 30 | ON | 100 ms continuous | Immediately | |
| Out of range low | Measured temperature | < 200 | [Digit s] | Terminal 30 | ON | 100 ms continuous | Immediately | |||
| Out of range high | Measured temperature | > 4090 | [Digit s] | Terminal 30 | ON | 100 ms continuous | Immediately | |||
| P0A94 - DC/DC Converter "A" Performance | Rationality low : Plausible check with other sensor measurement | Temperature difference between measurements at sensor t3 and t4 | < -400 | [Digit s] | Terminal 30 | ON | 100 ms continuous | 2 DCY | ||
| Rationality high : Plausible check with other sensor measurement | Temperature difference between measurements at sensor t3 and t4 | >400 | [Digit s] | Terminal 30 | ON | 100 ms continuous | 2 DCY | |||
| Temperature Sensor absolute value t4°C converted value t4 digits | P0A08 - DC/DC Converter Status Circuit | Other Rationality - Erratic intermittent contact check using rate of change temperature | Calculated rate of change of temperature measurement t4 with time | > 2.0 | [°C / s] | Terminal 30 | ON | 100 ms continuous | Immediately | |
| Out of range low | Measured temperature | < 200 | [Digit s] | Terminal 30 | ON | 100 ms continuous | Immediately | |||
| Out of range high | Measured temperature | > 4090 | [Digit s] | Terminal 30 | ON | 100 ms continuous | Immediately | |||
| P0A94 - DC/DC Converter "A" Performance | Rationality low : Plausible check with other sensor measurement | Temperature difference between measurements at sensor t4 and t1 | < -400 | [Digit s] | Terminal 30 | ON | 100 ms continuous | 2 DCY | ||
| Rationality high : Plausible check with other sensor measurement | Temperature difference between measurements at sensor t4 and t1 | >400 | [Digit s] | Terminal 30 | ON | 100 ms continuous | 2 DCY | |||
| Current Sensor Phase_1 Iph.1 | P0A08 - DC/DC Converter Status Circuit | Short to ground | Measured Current_Phase 1 | < -44 | [A] | Terminal 30 | ON | 100 ms continuous | Immediately | |
| Short to battery | Measured Current_Phase 1 | > 47.5 | [A] | Terminal 30 | ON | 100 ms continuous | Immediately | |||
| Out of range low | Measured Current_Phase 1 | < -41 | [A] | Terminal 30 | ON | 100 ms continuous | Immediately | |||
| Out of range high | Measured Current_Phase 1 | > 44.5 | [A] | Terminal 30 | ON | 100 ms continuous | Immediately | |||
| Rationality low : Plausible check with other sensor measurement Iph.2 | Current difference between measurements at phase 1 and 2 | < -2.5 | [A] | Terminal 30 | ON | 100 ms continuous | Immediately | |||
| Rationality high : Plausible check with other sensor measurement Iph.2 | Current difference between measurements at phase 1 and 2 | > 2.5 | [A] | Terminal 30 | ON | 100 ms continuous | Immediately | |||
| Current Sensor Phase_2 Iph.2 | Short to ground | Measured Current_Phase 2 | < -44 | [A] | Terminal 30 | ON | 100 ms continuous | Immediately | ||
| Short to battery | Measured Current_Phase 2 | > 47.5 | [A] | Terminal 30 | ON | 100 ms continuous | Immediately | |||
| Out of range low | Measured Current_Phase 2 | < -41 | [A] | Terminal 30 | ON | 100 ms continuous | Immediately | |||
| Out of range high | Measured Current_Phase 2 | > 44.5 | [A] | Terminal 30 | ON | 100 ms continuous | Immediately | |||
| Rationality low : Plausible check with other sensor measurement Iph.3 | Current difference between measurements at phase 2 and 3 | < -2.5 | [A] | Terminal 30 | ON | 100 ms continuous | Immediately | |||
| Rationality high : Plausible check with other sensor measurement Iph.3 | Current difference between measurements at | > 2.5 | [A] | Terminal 30 | ON | 100 ms continuous | Immediately | |||
| Current Sensor Phase_3 Iph.3 | Short to ground | Measured Current_Phase 3 | < -44 | [A] | Terminal 30 | ON | 100 ms continuous | Immediately | ||
| Short to battery | Measured Current_Phase 3 | > 47.5 | [A] | Terminal 30 | ON | 100 ms continuous | Immediately | |||
| Out of range low | Measured Current_Phase 3 | < -41 | [A] | Terminal 30 | ON | 100 ms continuous | Immediately | |||
| Out of range high | Measured Current_Phase 3 | > 44.5 | [A] | Terminal 30 | ON | 100 ms continuous | Immediately | |||
| Rationality low : Plausible check with other sensor measurement Iph.4 | Current difference between measurements at | < -2.5 | [A] | Terminal 30 | ON | 100 ms continuous | Immediately | |||
| Rationality high : Plausible check with other sensor measurement Iph.4 | Current difference between measurements at | > 2.5 | [A] | Terminal 30 | ON | 100 ms continuous | Immediately | |||
| Current Sensor Phase_4 Iph.4 | Short to ground | Measured Current_Phase 4 | < -44 | [A] | Terminal 30 | ON | 100 ms continuous | Immediately | ||
| Short to battery | Measured Current_Phase 4 | > 47.5 | [A] | Terminal 30 | ON | 100 ms continuous | Immediately | |||
| Out of range low | Measured Current_Phase 4 | < -41 | [A] | Terminal 30 | ON | 100 ms continuous | Immediately | |||
| Out of range high | Measured Current_Phase 4 | > 44.5 | [A] | Terminal 30 | ON | 100 ms continuous | Immediately | |||
| Rationality low : Plausible check with other sensor measurement Iph.5 | Current difference between measurements at phase 4 and 5 | < -2.5 | [A] | Terminal 30 | ON | 100 ms continuous | Immediately | |||
| Rationality high : Plausible check with other sensor measurement Iph.5 | Current difference between measurements at phase 4 and 5 | > 2.5 | [A] | Terminal 30 | ON | 100 ms continuous | Immediately | |||
| Current Sensor Phase_5 Iph.5 | Short to ground | Measured Current_Phase 5 | < -44 | [A] | Terminal 30 | ON | 100 ms continuous | Immediately | ||
| Short to battery | Measured Current_Phase 5 | > 47.5 | [A] | Terminal 30 | ON | 100 ms continuous | Immediately | |||
| Out of range low | Measured Current_Phase 5 | < -41 | [A] | Terminal 30 | ON | 100 ms continuous | Immediately | |||
| Out of range high | Measured Current_Phase 5 | > 44.5 | [A] | Terminal 30 | ON | 100 ms continuous | Immediately | |||
| Rationality low : Plausible check with other sensor measurement Iph.6 | Current difference between measurements at phase 5 and 6 | < -2.5 | [A] | Terminal 30 | ON | 100 ms continuous | Immediately | |||
| Rationality high : Plausible check with other sensor measurement Iph.6 | Current difference between measurements at phase 5 and 6 | > 2.5 | [A] | Terminal 30 | ON | 100 ms continuous | Immediately | |||
| Current Sensor Phase_6 Iph.6 | Short to ground | Measured Current_Phase 6 | < -44 | [A] | Terminal 30 | ON | 100 ms continuous | Immediately | ||
| Short to battery | Measured Current_Phase 6 | > 47.5 | [A] | Terminal 30 | ON | 100 ms continuous | Immediately | |||
| Out of range low | Measured Current_Phase 6 | < -41 | [A] | Terminal 30 | ON | 100 ms continuous | Immediately | |||
| Out of range high | Measured Current_Phase 6 | > 44.5 | [A] | Terminal 30 | ON | 100 ms continuous | Immediately | |||
| Rationality low : Plausible check with other sensor measurement Iph.7 | Current difference between measurements at phase 6 and 7 | < -2.5 | [A] | Terminal 30 | ON | 100 ms continuous | Immediately | |||
| Rationality high : Plausible check with other sensor measurement Iph.7 | Current difference between measurements at phase 6 and 7 | > 2.5 | [A] | Terminal 30 | ON | 100 ms continuous | Immediately | |||
| Current Sensor Phase_7 Iph.7 | Short to ground | Measured Current_Phase 7 | < -44 | [A] | Terminal 30 | ON | 100 ms continuous | Immediately | ||
| Short to battery | Measured Current_Phase 7 | > 47.5 | [A] | Terminal 30 | ON | 100 ms continuous | Immediately | |||
| Out of range low | Measured Current_Phase 7 | < -41 | [A] | Terminal 30 | ON | 100 ms continuous | Immediately | |||
| Out of range high | Measured Current_Phase 7 | > 44.5 | [A] | Terminal 30 | ON | 100 ms continuous | Immediately | |||
| Rationality low : Plausible check with other sensor measurement Iph.8 | Current difference between measurements at phase 7 and 8 | < -2.5 | [A] | Terminal 30 | ON | 100 ms continuous | Immediately | |||
| Rationality high : Plausible check with other sensor measurement Iph.8 | Current difference between measurements at phase 7 and 8 | > 2.5 | [A] | Terminal 30 | ON | 100 ms continuous | Immediately | |||
| Current Sensor Phase_8 Iph.8 | Short to ground | Measured Current_Phase 8 | < -44 | [A] | Terminal 30 | ON | 100 ms continuous | Immediately | ||
| Short to battery | Measured Current_Phase 8 | > 47.5 | [A] | Terminal 30 | ON | 100 ms continuous | Immediately | |||
| Out of range low | Measured Current_Phase 8 | < -41 | [A] | Terminal 30 | ON | 100 ms continuous | Immediately | |||
| Out of range high | Measured Current_Phase 8 | > 44.5 | [A] | Terminal 30 | ON | 100 ms continuous | Immediately | |||
| Rationality low : Plausible check with other sensor measurement Iph.1 | Current difference between measurements at phase 8 and 1 | < -2.5 | [A] | Terminal 30 | ON | 100 ms continuous | Immediately | |||
| Rationality high : Plausible check with other sensor measurement Iph.1 | Current difference between measurements at phase 8 and 1 | > 2.5 | [A] | Terminal 30 | ON | 100 ms continuous | Immediately | |||
| Fan Current Sensor I_fan | P0A94 - DC/DC Converter "A" Performance | Short to ground | Measured Current at Fan terminal | < 0.015 | [A] | Fan duty cycle | ≥ 60 | [%] | 100 ms continuous | 2 DCY |
| Short to battery | Measured Current at Fan terminal | > 1.1 | [A] | Fan duty cycle | ≥ 60 | [%] | 100 ms continuous | 2 DCY | ||
| Out of range low | Measured Current at Fan terminal | < 0.03 | [A] | Fan duty cycle | ≥ 60 | [%] | 100 ms continuous | 2 DCY | ||
| Out of range high | Measured Current at Fan terminal | > 1.0 | [A] | Fan duty cycle | ≥ 60 | [%] | 100 ms continuous | 2 DCY | ||
| Rationality low : Plausible check with duty cycle (x) based limit value (y) | Measured Current at Fan terminal is evaluated with limit value | see sheet fan compensation | [mA] | Fan duty cycle | ≥ 60 | [%] | 100 ms continuous | 2 DCY | ||
| Rationality high : Plausible check with duty cycle (x) based limit value (y) | Measured Current at Fan terminal is evaluated with limit value | see sheet fan compensation | [mA] | Fan duty cycle | ≥ 60 | [%] | 100 ms continuous | 2 DCY | ||
| FAN actuator functional check | FAN open circuit / not plugged in to circuit | Measured current at Fan terminal | < 0.015 | [A] | Terminal 30 | ON | 100 ms continuous | 2 DCY | ||
| FAN overload failure | Measured current at Fan terminal | > 1.2 | [A] | Terminal 30 | ON | 100 ms continuous | 2 DCY | |||
| FAN Blocked condition check by comparing fan terminal current measurement with duty cycle (x) based limit value (y) | Calculated fan speed based on current measurement is lower than limit value | see sheet fan compensation | [1/mi n] | Fan duty cycle | ≥ 60 | [%] | 100 ms continuous | 2 DCY | ||
| FAN Broken condition check by comparing fan terminal current measurement with duty cycle (x) based limit value (y) | Calculated fan speed based on current measurement is higher than limit value | see sheet fan compensation | [1/mi n] | Fan duty cycle | ≥ 60 | [%] | 100 ms continuous | 2 DCY | ||
| Overall System Performance Check | P0D32 - DC/DC Converter "A" Over Temperature | Measured temperature from all 4 sensors | Maximum temperature out of all sensor measurements | > 85 | [°C] | Terminal 30 | ON | 100 ms continuous | Immediately | |
| P0A94 - DC/DC Converter "A" Performance | Conversion efficiency out of limit | Ratio of output power to input power is conversion efficiency. The calculated value is compared with input current (x) based high and low efficiency limit values (y). The input current x is the sum of all 8 current sensor measurements | High limit y = +100.1082915x0 -0.005853603x1 -4.57111e-5x2 +1.18206e-7x3 +1.12654e-11x4 ymax =100 Low limit = +78.50336709x0 +0.831397432x1 -0.020975461x2 +0.000268758x3 -1.89771e-6x4 +7.37869e-9x4 -1.47418e-11x5 +1.1789e-14x6 y min =84 | [%] | I_Terminal 30 U_Terminal 30 DCDC output power | ≥ 8 > 9 ≥ 100 | [A] [V] [W] | 100 ms continuous | 2 DCY | |
| P0CA3 - DC/DC Converter Step Up Voltage Performance | Terminal 40_Under voltage with shut off detected | Measured voltage Terminal 40 | < 17 | [V] | Terminal 40 Precharge | ON Completed | 100 ms continuous | 2 DCY | ||
| P0A08 - DC/DC Converter Status Circuit | Check if DCDC is non functional in safe state due to Functional Safety Monitor | |||||||||
| U031B - Software Incompatibility With DC/DC Converter Control Module "A" | Functional check of applicable OBD software configuration | CAN Signal Data set variable : OBD Mode | = US_OBD = 1 | [-] | Terminal 30 OBD_Config_Check | ON Possible | 100 ms continuous | 2 DCY | ||
| Micro controller Internal Error | P0A08 - DC/DC Converter Status Circuit | RAM monitor | Number of internal RAM errors | > 10 | [-] | Terminal 30 | ON | 100 ms continuous | Immediately | |
| ROM monitor | Number of internal ROM errors | > 5 | [-] | Terminal 30 | ON | 100 ms continuous | Immediately | |||
| NVM Monitor | Stored and calculated checksum | NOT MATCHING | [-] | Initialization | ON | Only during initialization | Immediately | |||
| WD monitor | Number of consecutive WD resets | > 5 | [-] | Initialization | ON | Only during initialization | Immediately | |||
| CAN_RAM monitor | Internal error detected at CAN RAM portion | TRUE | [-] | Initialization | ON | Only during initialization | Immediately | |||
| CAN Communication failures | U014A - Lost Communication With Battery Energy Control Module "C" | Time out check | BMS_MV_01 BMS_MV_04 | > 0.5 >5 | s | H_CAN_diagnostics | Enabled | 100 ms continuous | 2 DCY | |
| U0100 - Lost Communication With ECM/PCM "A" | Time out check | Motor_Code_01 Motor_07 Motor_28 | >5 >5 >2 | s | H_CAN_diagnostics | Enabled | 100 ms continuous | 2 DCY | ||
| U0146 - Lost Communication With Serial Data Gateway Module "A" | Time out check | MVK_01 Klemmen_Status_01 Systeminfo_01 | 0.5 1.0 5.0 | s | H_CAN_diagnostics | Enabled | 100 ms continuous | 2 DCY | ||
| U014A - Lost Communication With Battery Energy Control Module "C" | Invalid value | BMS_MV_IstSpannung MV_On BMS_MV_IstModus BMS_MV_IstSpannung MV_On BMS_MVIstModus | ERROR ERROR ERROR Init Init Init | [-] | H_CAN_diagnostics | Enabled | 100 ms continuous | 2 DCY | ||
| U0146 - Lost Communication With Serial Data Gateway Module "A" | Invalid value | MVK_DCDC_Sollmodus_02 | ERROR | [-] | H_CAN_diagnostics | Enabled | 100 ms continuous | 2 DCY | ||
| Global time out check | no received message observed | TIME OUT | [-] | 100 ms continuous | 2 DCY | |||||
| Bus Off at HCAN | ERROR | [-] | ||||||||
| Safety micro controller internal failure | P0A08 - DC/DC Converter Status Circuit | Safety Controller software version mismatch | Communication from safety micro controller Software ID matches with stored values | Enabled Not matching | [-] | Initialization | ON | Only during initialization | Immediately | |
| Safety controller not working | Safety controller communication request | Not answered | [-] | Initialization | ON | 100 ms continuous | Immediately | |||
| DCDC Converter control loop monitor | Failure occurrence frequency | Number of failure occurrences Time window | > 5 > 10 | [numbers] [minutes] | Initialization | ON | 100 ms continuous | Immediately | ||
| Precharge function monitor | P0A94 - DC/DC Converter "A" Performance | Terminal 40_Precharge rationality | Voltage difference between target and measured voltage time since precharge start as percentage of target ramp time | > 3 > 170 | [V] [%] of time | Precharge and DCDC_FSM_Precharge_Boost_ Ramp_Active | Enabled Enabled | Only during precharge | 2 DCY | |