LEMON Manuals: Even more car manuals for everyone: 1960-2025
Home >> Audi >> 2025 >> Q5 e Premium Plus >> Repair and Diagnosis >> Engine Performance >> Testing & Diagnosis >> Generic Scan Tool (DSMA) (Battery Charger Control Module DTC Tables) >> St Generic Scan Tool >> Diagnosis And Testing >> Battery Charger Control Module DTC Tables >> Battery Charger Control Module (BCCM) --, 2025 MY
April 5, 2026: LEMON Manuals is launched! Read the announcement.

Battery Charger Control Module (BCCM) --, 2025 MY

Component / System DTC / DTC Description Monitor Strategy Description Malfunction Criteria Threshold Value Unit Secondary Parameters Enable Condition Unit Monitoring Time Length / Frequency of Monitor MIL Illum.
Supply voltage sensor P0E5E - Battery Charger Control Module "A" Processor Performance Supply voltage sensor upper limit exceeded (ORH) supply voltage sensor value >23 [V] ECU is active TRUE [-] 2 [s] continuous 2 DCY
Supply voltage restriction due to under voltage supply voltage sensor value <=9 [V] ECU is active TRUE [-] 5 [s] continuous
Supply voltage restriction due to over voltage supply voltage sensor value >=16 [V] ECU is active TRUE [-] 5 [s] continuous
Supply voltage lower limit exceeded (ORL) supply voltage sensor value <=9 [V] ECU is active TRUE [-] 90 [s] continuous
Supply voltage upper limit exceeded (ORH) supply voltage sensor value >=16 [V] ECU is active TRUE [-] 90 [s] continuous
Supply voltage sensor lower limit exceeded (ORL) supply voltage sensor value <= 2.5 [V] ECU is active TRUE [-] 2 [s] continuous
Supply voltage sensor implausible value (RAT) plug interlock voltage sensor value > 0.65 * U_Batt [V]   5 [s] continuous
OR    
plug interlock voltage sensor value < 0.36 * U_Batt [V] car velocity > 0 [mph]
AND     AND    
plug interlock voltage sensor value > 0.23 * U_Batt [V] for time >= 30 [s]
OR      
plug interlock voltage sensor value < 0.05 * U_Batt [V]
HV-DC voltage sensor 1 HV-DC voltage sensor 1 upper limit exceeded (ORH) HV-DC voltage sensor value > 654.3 [V] ECU is active TRUE [-] 4 [s] continuous 2 DCY
AND    
HV-DC voltage sensor value <= 690.6 [V]
HV-DC voltage sensor 1 short circuit to ground (SCG) HV-DC voltage sensor value < -43.6 [V] ECU is active TRUE [-] 4 [s] continuous
HV-DC voltage sensor 1 short circuit to plus (SCB) HV-DC voltage sensor value > 690.6 [V] ECU is active TRUE [-] 4 [s] continuous
HV-DC voltage sensor 1 lower limit exceeded (ORL) HV-DC voltage sensor value < -16.4 [V] ECU is active TRUE [-] 4 [s] continuous
AND    
HV-DC voltage sensor value >= -43.6 [V]
HV-DC voltage sensor 1 erratic Occurrence frequency >= 20 [1/10sec] absolute value of sensor value jump >= 50 [V/sec] 30 [s] continuous
HV-DC voltage sensor 2 HV-DC voltage sensor 2 lower limit exceeded (ORL) HV-DC voltage sensor value < -16.4 [V] ECU is active TRUE [-] 4 [s] continuous 2 DCY
AND    
HV-DC voltage sensor value >= -43.6 [V]
HV-DC voltage sensor 2 upper limit exceeded (ORH) HV-DC voltage sensor value > 654.3 [V] ECU is active TRUE [-] 4 [s] continuous
AND    
HV-DC voltage sensor value <= 690.6 [V]
HV-DC voltage sensor 2 short circuit to ground (SCG) DC voltage < -43.6 [V] ECU is active TRUE [-] 4 [s] continuous
HV-DC voltage sensor 2 short circuit to plus (SCB) DC voltage > 690.6 [V] ECU is active TRUE [-] 4 [s] continuous
HV-DC voltage sensor 2 erratic Occurrence frequency >= 20 [1/10 sec] absolute value of sensor value jump >= 50 [V/sec] 30 [s] continuous
HV-DC voltage sensor 3 HV-DC voltage sensor 3 lower limit exceeded (ORL) HV-DC voltage sensor value < -19.4 [V] ECU is active TRUE [-] 4 [s] continuous 2 DCY
AND    
HV-DC voltage sensor value >= -23.8 [V]
HV-DC voltage sensor 3 short circuit to ground (SCG) DC voltage < -23.8 [V] ECU is active TRUE [-] 4 [s] continuous
HV-DC voltage sensor 3 erratic Occurrence frequency >= 20 [1/10 sec] absolute value of sensor value jump >= 50 [V/sec] 30 [s] continuous
HV-DC voltage sensor HV-DC voltage sensor implausible value (RAT) absolute value of difference between HV-DC voltage sensor 1 and sensor 2 values > 40 [V] ECU is active TRUE [-] 4 [s] continuous 2 DCY
DCDC supply voltage DCDC supply voltage sensor short circuit to plus (SCB) DCDC supply voltage sensor value > 36.3 [V] ECU is active TRUE [-] 1 [s] continuous 2 DCY
DCDC supply voltage sensor short circuit to ground (SCG) DCDC supply voltage sensor value < 0.3 [V] ECU is active TRUE [-] 1 [s] continuous
DCDC supply voltage sensor upper limit exceeded (ORH) DCDC supply voltage sensor value > 36.2 [V] ECU is active TRUE [-] 1 [s] continuous
AND    
DCDC supply voltage sensor value <= 36.3 [V]
DCDC supply voltage sensor lower limit exceeded (ORL) DCDC supply voltage sensor value < 1.3 [V] ECU is active TRUE [-] 1 [s] continuous
AND    
DCDC supply voltage sensor value >= 0.3 [V]
  Communication to DCDC-digital signal processor on [-]       1 [s]
DCDC supply voltage sensor implausible value (RAT) AND     ECU is active TRUE [-] continuous  
DCDC-digital signal processor supply voltage sensor value < 2 [V]
DCDC supply voltage sensor erratic Occurrence frequency >= 16 [1/10 sec] absolute value of sensor value jump >= 4 [V/sec] 30 [s] continuous
3.3 V supply voltage 3.3 V supply voltage sensor short circuit to ground (SCG) 3v3_power_supply voltage sensor value < 1.6 [V] system reset yes [-] 1 [s] continuous 2 DCY
3.3 V supply voltage sensor upper limit exceeded (ORH) 3v3_power_supply voltage sensor value > 3.4 [V] system reset yes [-] 1 [s] continuous
3.3 V supply voltage sensor lower limit exceeded (ORL) 3v3_power_supply voltage sensor value < 3.2 [V] system reset yes [-] 1 [s] continuous
3.3 V supply voltage sensor erratic Occurrence frequency >= 16 [1/10 sec] absolute value of sensor value jump >= 1 [V/sec] 30 [s] continuous
DCDC input current DCDC input current Rail 1 too high (over current shutoff) DCDC-digital signal processor detected a Rail1 DC-over current (HW) - Stage 2 of > 67.4 [A] Charging mode active [-] 1 [s] continuous 2 DCY
AND    
Number of occurrences >=3 [-]
DCDC input current Rail 2 too high (over current shutoff) DCDC-digital signal processor detected a Rail 2 DC-Over current (HW) - Stage 2 of > 67.4 [A] Charging mode active [-] 1 [s] continuous
AND    
Number of occurrences >=3 [-]
Temperature sensor coolant Temperature sensor coolant upper limit exceeded (ORH) temperature sensor value > 130 [°C] ECU is active TRUE [-] 1 [s] 2 DCY
Temperature sensor coolant lower limit exceeded (ORL) temperature sensor value < -40 [°C] ECU is active TRUE [-] 1 [s] continuous
Temperature sensor coolant implausible value (RAT) absolute value of the difference between temperature of the DCDC coil and coolant temperature > 15 [°C] car velocity > 0 [mph] 30 [s] once per driving cycle
AND    
for time >= 10 [min]
Temperature sensor coolant over temperature temperature sensor value > 100 [°C] for time 5 [min] 1 [s]
Temperature sensor coolant erratic Occurrence frequency >=10 [1/h] absolute value of sensor value jump >= 20 [K/sec] 1 [h] continuous
Temperature sensor signal electronics Temperature sensor signal electronics lower limit exceeded (ORL) temperature sensor value < -45 [°C] ECU is active TRUE [-] 1 [s] continuous 2 DCY
Temperature sensor signal electronics upper limit exceeded (ORH) temperature sensor value > 150 [°C] ECU is active TRUE [-] 1 [s] continuous
Temperature sensor signal electronics implausible value (RAT) absolute value of the difference between temperature of the Printed Circuit Board temperature sensor and coolant temperature > 55 [°C] ECU is active TRUE [-] 61 [s] continuous
Temperature sensor signal electronics erratic Occurrence frequency >=10 [1/h] absolute value of sensor value jump >= 20 [K/sec] 1 [h] continuous
Temperature sensor Power Factor Correction 1 Temperature sensor Power Factor Correction 1 implausible value (RAT) absolute difference with two or more other digital signal processor sensors > 50 [°C] ECU is active TRUE [-] 1 [s] continuous 2 DCY
Temperature sensor Power Factor Correction 1 erratic Occurrence frequency >=10 [1/h] absolute value of sensor value jump >= 20 [K/s] 1 [h] continuous
Temperature sensor Power Factor Correction 2 Temperature sensor Power Factor Correction 2 implausible value (RAT) absolute difference with two or more other digital signal processor sensors > 50 [°C] ECU is active TRUE [-] 1 [s] continuous 2 DCY
Temperature sensor Power Factor Correction 2 erratic Occurrence frequency >=10 [1/h] absolute value of sensor value jump >= 20 [K/sec] 1 [h] continuous
Temperature sensor DCDC 1 Temperature sensor DCDC 1 upper limit exceeded (ORH) temperature sensor value > 130 [°C] ECU is active TRUE [-] 1 [s] continuous 2 DCY
Temperature sensor DCDC 1 lower limit exceeded (ORL) temperature sensor value < -50 [°C] ECU is active TRUE [-] 1 [s] continuous
Temperature sensor DCDC 1 implausible value (RAT) absolute difference with two or more other digital signal processor sensors > 50 [°C] ECU is active TRUE [-] 1 [s] continuous
Temperature sensor DCDC 1 erratic Occurrence frequency >=10 [1/h] absolute value of sensor value jump >= 20 [K/sec] 1 [h] continuous
Temperature sensor DCDC 2 Temperature sensor DCDC 2 upper limit exceeded (ORH) temperature sensor value > 130 [°C] ECU is active TRUE [-] 1 [s] continuous 2 DCY
Temperature sensor DCDC 2 lower limit exceeded (ORL) temperature sensor value < -50 [°C] ECU is active TRUE [-] 1 [s] continuous
Temperature sensor DCDC 2 implausible value (RAT) Difference with two or more other digital signal processor sensors > 50 [°C] ECU is active TRUE [-] 1 [s] continuous
Temperature sensor DCDC 2 erratic Occurrence frequency >=10 [1/h] absolute value of sensor value jump >= 20 [K/sec] 1 [h] continuous
        LHVIL coded yes [-]    
AND    
Safety line (local HV interlock) Safety line (local HV Interlock) evaluation defect Error in evaluation function detected [-] clamp 30 Voltage >= 9 [V] 500 [ms] continuous 2 DCY
AND    
clamp 30 Voltage <= 16 [V]
AND    
System Board temperature >= -40 [°C]
AND    
System Board temperature <= 130 [°C]
S2 S2 malfunction S2 state closed [-] ECU is active TRUE [-] 2 [s] continuous 2 DCY
AND    
CP voltage > 7 [V]
OR    
S2 state closed [-]
AND    
CP voltage < 5 [V]
OR    
S2 state open [-]
AND    
CP voltage > 10 [V]
OR    
S2 state open [-]
AND    
CP voltage < 8 [V]
Relay Readback control phase switching 1 short circuit to plus (SCB) sensor value > 25.7 [V] ECU is active TRUE [-] 1 [s] continuous 2 DCY
Readback control phase switching 1 short circuit to ground (SCG) sensor value < 0.3 [V] ECU is active TRUE [-] 1 [s] continuous
Readback control phase switching 1 upper limit exceeded (ORH) sensor value > 25.4 [V] ECU is active TRUE [-] 1 [s] continuous
AND    
sensor value <= 25.7 [V]
Readback control phase switching 1 lower limit exceeded (ORL) sensor value < 1.3 [V] ECU is active TRUE [-] 1 [s] continuous
AND    
sensor value >= 0.3 [V]
Relay phase switching 1 stuck open Power Factor Correction - Digital Signal Processor reports relay phase error on rail 2 yes [-] charge release is given yes [-] 500 [ms] continuous
AND    
Number of occurrences >=3 [-]
DCDC Digital Signal Processor Undefined state of the State Machine DCDC DCDC-digital signal processor state-machine is in undefined state yes [-] ECU is active TRUE [-] 1 [s] continuous 2 DCY
AND    
Number of occurrences >=3 [-]
RAM-Error DCDC DCDC-digital signal processor reports RAM- Error yes [-] ECU is active TRUE [-] 1 [s] continuous
AND    
Number of occurrences >=3 [-]
ROM-Error DCDC DCDC-digital signal processor reports Flash- yes [-] ECU is active TRUE [-] 1 [s] continuous
AND    
Number of occurrences >=3 [-]
Control unit defect Check of RAM buffer failed RAM buffer error detected [-] ECU is active TRUE [-] 1 [s] continuous 2 DCY
Check sum of ROM areas failed check sum error detected [-] ECU is active TRUE [-] 1 [s] continuous
Defective EEPROM memory read job failed [-] EEPROM memory diagnosis yes [-] 1 [s] once per driving cycle
OR    
write job failed [-]
OR    
compare job failed [-]
OR    
communication test job failed [-]
OR    
erase job failed [-]
OR    
unlock job failed [-]
Defective DataFlash memory erase job failed [-] DataFlash memory diagnosis yes [-] 1 [s] once per driving cycle
OR    
read job failed [-]
OR    
write job failed [-]
OR    
compare job failed [-]
Control unit defective Watchdog error Watchdog error detected [-] ECU is active TRUE [-] 1 [s] continuous
Controller internal communication error Internal communication error detected [-] ECU is active TRUE [-] 90 [s] continuous
  Digital Signal Processor error detected yes [-] Charging mode active [-] 1 [s]
Control unit internal counter error AND     OR     continuous  
Number of occurrences >=5 [-] Charging mode requested [-]
AD-Unit-1 Check: upper limit exceeded (ORH) any ADC measured value > 783 [digits] ECU is active TRUE [-] 1 [s] continuous
AD-Unit-1 Check: lower limit exceeded (ORL) any ADC measured value < 241 [digits] ECU is active TRUE [-] 1 [s] continuous
Error software coding variant system Reference resistor does not match any voltage range to derive variants (HW-Sample Version, Power-Class) from it yes [-] ECU is active TRUE [-] 1 [s] continuous
Error while shutdown Error counter >=2 [-] ECU is active TRUE [-] 1 [s] continuous
Secure Boot error Error in Secure Boot detected [-] ECU is active TRUE [-] 1 [s] continuous
Coding Variant coding DCDC Digital Signal Processor defective EcuHWNumber[10] == 'A'   ECU is active TRUE [-] 1 [s] continuous 2 DCY
OR    
EcuHWNumber[10] == 'Q'  
AND    
DCDC-digital signal processor reports detected Voltage-Variant == 800 [V]
Program coding Power Factor Correction Digital Signal Processor defective Unexpected software coding detected yes [-] ECU is active TRUE [-] 1 [s] continuous 2 DCY
Program coding DCDC Digital Signal Processor defective Unexpected software coding detected yes [-] ECU is active TRUE [-] 1 [s] continuous 2 DCY
OBD Monitoring P0D5C - Battery Charger Hybrid/EV Battery Output Power Performance Efficiency too low efficiency < 80 [%] active charging yes [-] 60 [s] continuous 2 DCY
AND    
input power > 1000 [W]
Temperature sensor coolant P0D24 - Battery Charger "A" Temperature Too High Shutdown due to over temperature temperature sensor coolant inlet temperature sensor value > 80 [°C] ECU is active TRUE [-] 1 [s] continuous 2 DCY
Temperature sensor signal electronics Shutdown due to over temperature temperature sensor signal electronics temperature sensor value > 130 [°C] Charging mode active [-] 1 [s] continuous 2 DCY
Temperature sensor Power Factor Correction 1 Shutdown due to over temperature temperature sensor Power Factor Correction 1 temperature sensor value > 130 [°C] Charging mode active [-] 1 [s] continuous 2 DCY
AND    
Number of occurrences >=3 [-]
Temperature sensor Power Factor Correction 2 Shutdown due to over temperature temperature sensor Power Factor Correction 2 temperature sensor value > 130 [°C] Charging mode active [-] 1 [s] continuous 2 DCY
AND    
Number of occurrences >=3 [-]
Temperature sensor DCDC 1 Shutdown due to over temperature temperature sensor DCDC 1 temperature sensor value > 130 [°C] Charging mode active [-] 1 [s] continuous 2 DCY
AND    
Number of occurrences >=3 [-]
Temperature sensor DCDC 2 Shutdown due to over temperature temperature sensor DCDC 2 temperature sensor value > 130 [°C] Charging mode active [-] 1 [s] continuous 2 DCY
AND    
Number of occurrences >=3 [-]
Coding U0337 - Software Incompatibility with Battery Charger Control Module "A" Monitoring of invalid coding value invalid coding value detected yes [-] ECU is active TRUE [-] 100 [ms] continuous 1DCY
Dataset Download Invalid dataset invalid data detected yes [-] RAM check successful yes [-] 100 [ms] continuous 1DCY
AND    
ROM check successful yes [-]
Monitoring of implausible dataset implausible data detected yes [-] RAM check successful yes [-] 100 [ms] continuous 1DCY
AND    
ROM check successful yes [-]
Production mode Production mode active production mode active [-] ECU is active TRUE [-] 100 [ms] continuous 1DCY
Charging flap lock Charging flap locked due to workshop mode Charging flap locking request yes [-] ECU is active TRUE [-] 100 [ms] continuous 1DCY
Temperature Sensor Socket AC P0D99 - Battery Charger Coupler Temperature Sensor "A" Circuit Charging socket AC temperature sensor erratic Occurrence frequency >=10 [1/h] absolute value of sensor value jump >= 20 [K/sec] 1 [h] continuous 2 DCY
Temperature Socket AC P0E5F - Battery Charger Coupler Temperature "A" Too High Charging socket AC over temperature temperature sensor value >= 80 [°C] AC plug PLUGGED [-] 5 [s] continuous 2 DCY
AC voltage sensor L1 P0D67 - Battery Charger Control Module "A" Performance AC voltage sensor L1 upper limit exceeded (ORH) voltage sensor value > 482.4 [V] ECU is active TRUE [-] 4 [s] continuous 2 DCY
AND    
voltage sensor value <= 494.8 [V]
AC voltage sensor L1 short circuit to ground (SCG) voltage sensor value < -482.9 [V] ECU is active TRUE [-] 4 [s] continuous
AC voltage sensor L1 short circuit to plus (SCB) voltage sensor value > 494.8 [V] ECU is active TRUE [-]  
AC voltage sensor L1 lower limit exceeded (ORL) voltage sensor value < -446.7 [V] ECU is active TRUE [-] 4 [s] continuous
AND    
voltage sensor value >= -482.9 [V]
AC voltage sensor L1 implausible value (RAT) AC-Voltage > 50 [V] car velocity > 3.1 [mph] 4 [s] continuous
AC voltage sensor L2 upper limit exceeded (ORH) voltage sensor value > 482.4 [V] ECU is active TRUE [-] 4 [s] continuous  
AND    
voltage sensor value <= 494.8 [V]
AC voltage sensor L2 AC voltage sensor L2 short circuit to ground (SCG) voltage sensor value < -482.9 [V] ECU is active TRUE [-] 4 [s] continuous 2 DCY
AC voltage sensor L2 short circuit to plus (SCB) voltage sensor value > 494.8 [V] ECU is active TRUE [-] 4 [s] continuous
AC voltage sensor L2 lower limit exceeded (ORL) voltage sensor value < -446.7 [V] ECU is active TRUE [-] 4 [s] continuous
AND    
voltage sensor value >= 482.9 [V]
AC voltage sensor L2 implausible value (RAT) AC-Voltage > 50 [V] car velocity > 3.1 [mph] 4 [s] continuous
Power Transmission Power-Overload Rail 1 (DCDC) DCDC-digital signal processor detected an HV Power-Overload for Rail 1 of > 3.96 [kW] active charging process over Rail1 yes [-] 1 [s] continuous 2 DCY
AND     AND    
Number of occurrences >=3 [-] for a time of >10 [s]
Power-Overload Rail 2 (DCDC) DCDC-digital signal processor detected an HV Power-Overload for Rail 2 of > 3.96 [kW] active charging process over Rail2 yes [-] 1 [s] continuous
AND     AND    
Number of occurrences >=3 [-] for a time of >10 [s]
DC link voltage sensor Rail 1 Voltage measurement DC-link Rail1 short circuit to plus (SCB) DC link voltage sensor value > 546.1 [V] ECU is active TRUE [-] 1 [s] continuous 2 DCY
Voltage measurement DC-link Rail 1 short circuit to ground (SCG) DC link voltage sensor value < -38.1 [V] ECU is active TRUE [-] 1 [s] continuous
Voltage measurement DC-link Rail 1 upper limit exceeded (ORH) DC link voltage sensor value > 538.8 [V]   TRUE [-] 1 [s] continuous
AND       TRUE [-]
DC link voltage sensor value <= 546.1 [V] ECU is active TRUE [-]
Voltage measurement DC-link Rail 1 lower limit exceeded (ORL) DC link voltage sensor value < -13.5 [V] ECU is active TRUE [-] 1 [s] continuous
AND    
DC link voltage sensor value >= -38.1 [V]
Voltage measurement DC-link Rail 1 implausible value (RAT) absolute value of difference between DC link voltage and AC peak voltage > 30 [V] ECU is active TRUE [-] 1 [s] continuous
AND    
Number of occurrences >=3 [-]
Fast voltage measurement DC-link Rail 1 implausible value (RAT) Deviation between interlink voltages > 50 [V] ECU is active TRUE [-] 300 [s] continuous
DC link over voltage Rail 1 Over voltage shutoff DC-link Rail 1 power factor correction-digital signal processor detected a Rail 1 interlink over voltage - stage 2 of > 432 [V] ECU is active TRUE [-] 500 [ms] continuous 2 DCY
AND    
Number of occurrences >=3 [-]
DC link voltage sensor Rail 2 Voltage measurement DC-link Rail 2 short circuit to plus (SCB) DC link voltage sensor value > 546.1 [V] ECU is active TRUE [-] 1 [s] continuous 2 DCY
Voltage measurement DC-link Rail 2 short circuit to ground (SCG) DC link voltage sensor value < -38.1 [V] ECU is active TRUE [-] 1 [s] continuous
Voltage measurement DC-link Rail 2 upper limit exceeded (ORH) DC link voltage sensor value > 538.8 [V] ECU is active TRUE [-] 1 [s] continuous
AND    
DC link voltage sensor value <= 546.1 [V]
Voltage measurement DC-link Rail 2 lower limit exceeded (ORL) DC link voltage sensor value < -13.5 [V] ECU is active TRUE [-] 1 [s] continuous
AND    
DC link voltage sensor value >= -38.1 [V]
Voltage measurement DC-link Rail 2 implausible value (RAT) absolute value of difference between DC link voltage and AC peak voltage > 30 [V] ECU is active TRUE [-] 1 [s] continuous
AND    
Number of occurrences >=3 [-]
Fast voltage measurement DC-link Rail 2 implausible value (RAT) Deviation between interlink voltages > 50 [V] ECU is active TRUE [-] 300 [s] continuous
DC link over voltage Rail 2 Over voltage shutoff DC-link Rail 2 power factor correction-digital signal processor detected a Rail 2 interlink over voltage - stage 2 of > 432 [V] ECU is active TRUE [-] 500 [ms] continuous 2 DCY
AND    
Number of occurrences >=3 [-]
Fast voltage measurement DC link voltage sensor Fast voltage measurement DC-link Rail 1 short circuit to plus (SCB) DC link voltage sensor value > 546.1 [V] ECU is active TRUE [-] 1 [s] continuous 2 DCY
Fast voltage measurement DC-link Rail 2 short circuit to plus (SCB) DC link voltage sensor value > 546.1 [V] ECU is active TRUE [-] 1 [s] continuous
Fast voltage measurement DC-link Rail 1 short circuit to ground (SCG) DC link voltage sensor value < -38.1 [V] ECU is active TRUE [-] 1 [s] continuous
Fast voltage measurement DC-link Rail 2 short circuit to ground (SCG) DC link voltage sensor value < -38.1 [V] ECU is active TRUE [-] 1 [s] continuous
Fast voltage measurement DC-link Rail 1 upper limit exceeded (ORH) DC link voltage sensor value > 538.8 [V] ECU is active TRUE [-] 1 [s] continuous
AND    
DC link voltage sensor value <= 546.1 [V]
Fast voltage measurement DC-link Rail 2 upper limit exceeded (ORH) DC link voltage sensor value > 538.8 [V] ECU is active TRUE [-] 1 [s] continuous  
AND    
DC link voltage sensor value <= 546.1 [V]
Fast voltage measurement DC-link Rail 1 lower limit exceeded (ORL) DC link voltage sensor value < -13.5 [V] ECU is active TRUE [-] 1 [s] continuous
AND    
DC link voltage sensor value >= -38.1 [V]
Fast voltage measurement DC-link Rail 2 lower limit exceeded (ORL) DC link voltage sensor value < -13.5 [V] ECU is active TRUE [-] 1 [s] continuous
AND    
DC link voltage sensor value >= -38.1 [V]
Power Factor Correction Gate driver voltage sensor Rail 1 Power Factor Correction 1 Gate driver voltage sensor short circuit to plus (SCB) power factor correction gate driver voltage > 25.7 [V] ECU is active TRUE [-] 1 [s] continuous 2 DCY
Power Factor Correction 1 Gate driver voltage sensor short circuit to ground (SCG) power factor correction gate driver voltage < 0.3 [V] ECU is active TRUE [-] 1 [s] continuous
Power Factor Correction 1 Gate driver voltage sensor upper limit exceeded (ORH) voltage sensor value > 25.4 [V] ECU is active TRUE [-] 1 [s] continuous
AND    
voltage sensor value <= 25.7 [V]
Power Factor Correction 1 Gate driver voltage sensor lower limit exceeded (ORL) voltage sensor value < 6.3 [V] ECU is active TRUE [-] 1 [s] continuous
AND    
voltage sensor value >= 0.3 [V]
Power Factor Correction 1 Gate driver voltage sensor implausible value (RAT) Gate driver of respective power factor correction-digital signal processor Rail 1 off [-] ECU is active TRUE [-] 1 [s] continuous
AND    
voltage sensor value > 6 [V]
Power Factor Correction 1 Gate driver voltage sensor erratic Occurrence frequency >= 16 [1/10 sec] absolute value of sensor value jump >= 4 [V/sec] 30 [s] continuous
Power Factor Correction supply voltage Rail 1 Power Factor Correction 1 supply voltage sensor short circuit to plus (SCB) power factor correction gate driver voltage > 36.3 [V] ECU is active TRUE [-] 1 [s] continuous 2 DCY
Power Factor Correction 1 supply voltage sensor short circuit to ground (SCG) power factor correction gate driver voltage < 0.4 [V] ECU is active TRUE [-] 1 [s] continuous
Power Factor Correction 1 supply voltage sensor upper limit exceeded (ORH) voltage sensor value > 35.8 [V] ECU is active TRUE [-] 1 [s] continuous
AND    
voltage sensor value <= 36.3 [V]
Power Factor Correction 1 supply voltage sensor lower limit exceeded (ORL) voltage sensor value < 1.8 [V] ECU is active TRUE [-] 1 [s] continuous
AND    
voltage sensor value >= 0.4 [V]
Power Factor Correction 1 supply voltage sensor implausible value (RAT) Communication to power factor correction- digital signal processor on [-] ECU is active TRUE [-] 1 [s] continuous
AND    
voltage sensor value < 2 [V]
Power Factor Correction 1 supply voltage sensor erratic Occurrence frequency >= 16 [1/10 sec] absolute value of sensor value jump >= 4 [V/sec] 30 [s] continuous
Power Factor Correction Gate driver voltage sensor Rail 2 Power Factor Correction 2 Gate driver voltage sensor short circuit to plus (SCB) voltage sensor value > 25.7 [V] ECU is active TRUE [-] 1 [s] continuous 2 DCY
Power Factor Correction 2 Gate driver voltage sensor short circuit to ground (SCG) voltage sensor value < 0.3 [V] ECU is active TRUE [-] 1 [s] continuous
Power Factor Correction 2 Gate driver voltage sensor upper limit exceeded (ORH) voltage sensor value > 25.4 [V] ECU is active TRUE [-] 1 [s] continuous
AND    
voltage sensor value <= 25.7 [V]
Power Factor Correction 2 Gate driver voltage sensor lower limit exceeded (ORL) voltage sensor value < 6.3 [V] ECU is active TRUE [-] 1 [s] continuous
AND    
voltage sensor value >= 0.3 [V]
Power Factor Correction 2 Gate driver voltage sensor implausible value (RAT) Gate driver of respective power factor correction-digital signal processor Rail 2 off [-] ECU is active TRUE [-] 1 [s] continuous
AND    
voltage sensor value > 6 [V]
Power Factor Correction 2 Gate driver voltage sensor erratic Occurrence frequency >= 16 [1/10 sec] absolute value of sensor value jump >= 4 [V/sec] 30 [s] continuous
Power Factor Correction supply voltage Rail 2 Power Factor Correction 2 supply voltage sensor short circuit to plus (SCB) voltage sensor value > 36.3 [V] ECU is active TRUE [-] 1 [s] continuous 2 DCY
Power Factor Correction 2 supply voltage sensor short circuit to ground (SCG) voltage sensor value < 0.4 [V] ECU is active TRUE [-] 1 [s] continuous
Power Factor Correction 2 supply voltage sensor upper limit exceeded (ORH) voltage sensor value > 35.8 [V] ECU is active TRUE [-] 1 [s] continuous
AND    
voltage sensor value <= 36.3 [V]
Power Factor Correction 2 supply voltage sensor lower limit exceeded (ORL) voltage sensor value < 1.8 [V] ECU is active TRUE [-] 1 [s] continuous
AND    
voltage sensor value >= 0.4 [V]
Power Factor Correction 2 supply voltage sensor implausible value (RAT) Communication to power factor correction- digital signal processor on [-] ECU is active TRUE [-] 1 [s] continuous
AND    
voltage sensor value < 2 [V]
Power Factor Correction 2 supply voltage sensor erratic Occurrence frequency >= 16 [1/10 sec] absolute value of sensor value jump >= 4 [V/sec] 30 [s] continuous
  DC current > 0.5 [A]          
DCDC short circuit Short circuit Rail 1 (DCDC) AND     active charging process over Rail 1 yes [-] 1 [s] continuous 2 DCY
DC voltage < 7.5 [V] AND    
AND     for a time of >= 25 [ms]
Number of occurrences >=3 [-]      
Short circuit Rail 2 (DCDC) DC current > 0.5 [A]       1 [s] continuous
AND     active charging process over Rail 2 yes [-]
DC voltage < 7.5 [V] AND    
AND     for a time of >= 25 [ms]
Number of occurrences >=3 [-]      
HV-DC current sensor HV-DC current sensor Rail 1 upper limit exceeded (ORH) current sensor value > 52.4 [A] ECU is active TRUE [-] 4 [s] continuous 2 DCY
AND    
current sensor value <= 56.4 [A]
HV-DC current sensor Rail 2 upper limit exceeded (ORH) current sensor value > 52.4 [A] ECU is active TRUE [-] 4 [s] continuous
AND    
current sensor value <= 56.4 [A]
HV-DC current sensor Rail 1 implausible value (RAT) absolute value of difference between actual DC output current and expected DC output current > 1 [A] active charging process over Rail 1 yes [-] 1 [s] continuous
AND    
voltage sensor value > 220 [V]
AND    
DC output power >= 1200 [W]
HV-DC current sensor Rail 2 implausible value (RAT) absolute value of difference between actual DC output current and expected DC output current > 1 [A] active charging process over Rail 2 yes [-] 1 [s] continuous
AND    
voltage sensor value > 220 [V]
AND    
DC output power >= 1200 [W]
HV-DC current sensor Rail 1 short circuit to ground (SCG) current sensor value < -8.7 [A] ECU is active TRUE [-] 4 [s] continuous
HV-DC current sensor Rail 2 short circuit to ground (SCG) current sensor value < -8.7 [A] ECU is active TRUE [-] 4 [s] continuous
HV-DC current sensor Rail 1 short circuit to battery (SCB) current sensor value > 56.4 [A] ECU is active TRUE [-] 4 [s] continuous
HV-DC current sensor Rail 2 short circuit to battery (SCB) current sensor value > 56.4 [A] ECU is active TRUE [-] 4 [s] continuous
HV-DC current sensor Rail 1 lower limit exceeded (ORL) current sensor value < -6.3 [A] ECU is active TRUE [-] 4 [s] continuous
AND    
current sensor value >= -8.7 [A]
HV-DC current sensor Rail 2 lower limit exceeded (ORL) current sensor value < -6.3 [A] ECU is active TRUE [-] 4 [s] continuous
AND    
current sensor value >= -8.7 [A]
HV-DC current sensor Rail 1 erratic Occurrence frequency >= 20 [1/10 sec] absolute value of sensor value jump >= 2 [A/sec] 30 [s] continuous
AND    
active charging process over Rail 1 yes [-]
AND    
commanded current set point for a time of >= 10 [s]
HV-DC current sensor Rail 2 erratic Occurrence frequency >= 20 [1/10 sec] absolute value of sensor value jump >= 2 [A/sec] 30 [s] continuous
AND    
active charging process over Rail2 yes [-]
AND    
commanded current set point for a time of >= 10 [s]
AC current sensor L 1 AC current sensor L 1 upper limit exceeded (ORH) current sensor value > 31.9 [A] ECU is active TRUE [-] 4 [s] continuous 2 DCY
AND    
current sensor value <= 32.3 [A]
AC current sensor L 1 supply implausible value (RAT) current sensor value < 0.5 [A] car velocity > 3.7 [mph] 4 [s] continuous
AC current sensor L 1 short circuit to ground (SCG) current sensor value < -2.8 [A] ECU is active   [-] 4 [s] continuous
AC current sensor L 1 short circuit to plus (SCB) current sensor value > 32.3 [A] ECU is active   [-] 4 [s] continuous
AC current sensor L 1 lower limit exceeded (ORL) current sensor value < -1.5 [A] ECU is active TRUE [-] 4 [s] continuous
AND    
current sensor value >= -2.8 [A]
AC current sensor L 1 erratic Occurrence frequency >= 20 [1/10 sec] absolute value of sensor value jump >= 2 [A/sec] 30 [s] continuous
AND    
active charging process over Rail 1 yes [-]
AND    
commanded current set point for a time of >= 10 [s]
AC current sensor L 2 upper limit exceeded (ORH) current sensor value > 31.9 [A] ECU is active TRUE [-] 4 [s] continuous  
AND    
current sensor value <= 32.3 [A]
AC current sensor L 2 supply implausible value (RAT) current sensor value < 0.5 [A] car velocity > 3.7 [mph] 4 [s] continuous
AC current sensor L 2 short circuit to ground (SCG) current sensor value < -2.8 [A] ECU is active   [-] 4 [s] continuous
AC current sensor L 2 AC current sensor L 2 short circuit to plus (SCB) current sensor value > 32.3 [A] ECU is active   [-] 4 [s] continuous 2 DCY
AC current sensor L 2 lower limit exceeded (ORL) current sensor value <-1.5 [A] ECU is active TRUE [-] 4 [s] continuous
AND    
current sensor value >= -2.8 [A]
AC current sensor L 2 erratic Occurrence frequency >= 20 [1/10sec] absolute value of sensor value jump >= 2 [A/sec] 30 [s] continuous
AND    
active charging process over Rail2 yes [-]
AND    
commanded current set point for a time of >= 10 [s]
Power Factor Correction current sensor Rail 1 Power Factor Correction current sensor Rail 1 stage 1 short circuit to plus (SCB) current sensor value > 30.0 [A] ECU is active TRUE [-] 1 [s] continuous 2 DCY
Power Factor Correction current sensor Rail 1 stage 1 short circuit to ground (SCG) current sensor value < -2.9 [A] ECU is active TRUE [-] 1 [s] continuous
Power Factor Correction current sensor Rail 1 stage 1 upper limit exceeded (ORH) current sensor value > 29.6 [A] ECU is active TRUE [-] 1 [s] continuous
AND    
current sensor value <= 30.0 [A]
Power Factor Correction current sensor Rail 1 stage 1 lower limit exceeded (ORL) current sensor value < -2.3 [A] ECU is active TRUE [-] 1 [s] continuous
AND    
current sensor value >= -2.9 [A]
Power Factor Correction current sensor Rail 1 implausible value (RAT) absolute value of difference between current Rail 1 stage 1 and current Rail 1 stage 2 > 5 [A] ECU is active TRUE [-] 100 [s] continuous
Power Factor Correction current sensor Rail 1 stage 2 short circuit to plus (SCB) current sensor value > 30.0 [A] ECU is active TRUE [-] 1 [s] continuous
Power Factor Correction current sensor Rail 1 stage 2 short circuit to ground (SCG) current sensor value < -2.9 [A] ECU is active TRUE [-] 1 [s] continuous
Power Factor Correction current sensor Rail 1 stage 2 upper limit exceeded (ORH) current sensor value > 29.6 [A] ECU is active TRUE [-] 1 [s] continuous
AND    
current sensor value <= 30.0 [A]
Power Factor Correction current sensor Rail 1 stage 2 lower limit exceeded (ORL) current sensor value < -2.3 [A] ECU is active TRUE [-] 1 [s] continuous
AND    
current sensor value >= -2.9 [A]
Shutdown due to over current Power Factor Correction Rail 1 power factor correction-digital signal processor detected Rail1 AC-Over current (HW) - Stage 2 yes [-] ECU is active TRUE [-] 1 [s] continuous
AND    
Number of occurrences >=3 [-]
Power Factor Correction current sensor Rail 1 erratic Occurrence frequency >= 20 [1/10 sec] absolute value of sensor value jump >= 2 [A/sec] 30 [s] continuous
AND    
active charging process over Rail 1 yes [-]
AND    
commanded current set point for a time of >= 10 [s]
Power Factor Correction current sensor Rail 2 Power Factor Correction current sensor Rail 2 stage 1 short circuit to plus (SCB) power factor correction current > 30.0 [A] ECU is active TRUE [-] 1 [s] continuous 2 DCY
Power Factor Correction current sensor Rail 2 stage 1 short circuit to ground (SCG) power factor correction current < -2.9 [A] ECU is active TRUE [-] 1 [s] continuous
Power Factor Correction current sensor Rail 2 stage 1 upper limit exceeded (ORH) current sensor value > 29.6 [A] ECU is active TRUE [-] 1 [s] continuous
AND    
current sensor value <= 30.0 [A]
Power Factor Correction current sensor Rail 2 stage 1 lower limit exceeded (ORL) current sensor value < -2.3 [A] ECU is active TRUE [-] 1 [s] continuous
AND    
current sensor value >= -2.9 [A]
Power Factor Correction current sensor Rail 2 implausible value (RAT) absolute value of difference between current Rail 2 stage 1 and current Rail 2 stage 2 > 5 [A] ECU is active TRUE [-] 100 [s] continuous
Power Factor Correction current sensor Rail 2 stage 2 short circuit to plus (SCB) power factor correction current > 30.0 [A] ECU is active TRUE [-] 1 [s] continuous
Power Factor Correction current censor Rail 2 stage 2 short circuit to ground (SCG) power factor correction current < -2.9 [A] ECU is active TRUE [-] 1 [s] continuous
Power Factor Correction current sensor Rail 2 stage 2 upper limit exceeded (ORH) current sensor value > 29.6 [A] ECU is active TRUE [-] 1 [s] continuous
AND    
current sensor value <= 30.0 [A]
Power Factor Correction current sensor Rail 2 stage 2 lower limit exceeded (ORL) current sensor value < -2.3 [A] ECU is active TRUE [-] 1 [s] continuous
AND    
current sensor value >= -2.9 [A]
Shutdown due to over current Power Factor Correction Rail 2 power factor correction-digital signal processor detected Rail 2 AC-Over current (HW) - Stage 2 yes [-] ECU is active TRUE [-] 1 [s] continuous
AND    
Number of occurrences >=3 [-]
Power Factor Correction current sensor Rail 2 erratic Occurrence frequency >= 20 [1/10 sec] absolute value of sensor value jump >= 2 [A/sec] 30 [s] continuous
AND    
active charging process over Rail 2 yes [-]
AND    
        commanded current set point for a time of >= 10 [s]    
Relay error - and phase control Read back control Inrush-Relais Rail 1 short circuit to plus (SCB) sensor value > 25.7 [V] ECU is active TRUE [-] 1 [s] continuous 2 DCY
Read back control Inrush-Relais Rail 1 short circuit to ground (SCG) sensor value < 0.3 [V] ECU is active TRUE [-] 1 [s] continuous
Read back control Inrush-Relais Rail 1 upper limit exceeded (ORH) voltage sensor value > 25.4 [V] ECU is active TRUE [-] 1 [s] continuous
AND    
voltage sensor value <= 25.7 [V]
Read back control Inrush-Relais Rail 1 lower limit exceeded (ORL) voltage sensor value < 1.3 [V] ECU is active TRUE [-] 1 [s] continuous
AND    
voltage sensor value >= 0.3 [V]
Read back control Inrush-Relais Rail 2 short circuit to plus (SCB) voltage sensor value > 25.7 [V] ECU is active TRUE [-] 1 [s] continuous
Read back control Inrush-Relais Rail 2 short circuit to ground (SCG) voltage sensor value < 0.3 [V] ECU is active TRUE [-] 1 [s] continuous
Read back control Inrush-Relais Rail 2 upper limit exceeded (ORH) voltage sensor value > 25.4 [V] ECU is active TRUE [-] 1 [s] continuous
AND    
voltage sensor value <= 25.7 [V]
Read back control Inrush-Relais Rail 2 lower limit exceeded (ORL) voltage sensor value < 1.3 [V] ECU is active TRUE [-] 1 [s] continuous
AND    
voltage sensor value >= 0.3 [V]
Digital Signal Processor State Machine Undefined state of State Machine Power Factor Correction 1 Undefined state of power factor correction- digital signal processor State-Machine detected yes [-] ECU is active TRUE [-] 1 [s] continuous 2 DCY
AND    
Number of occurrences >=3 [-]
Undefined state of State Machine Power Factor Correction 2 Undefined state of power factor correction- digital signal processor State-Machine detected yes [-] ECU is active TRUE [-] 1 [s] continuous
AND    
Number of occurrences >=3 [-]
Time Out for charging of the Interlink-Capacitors Rail 1 (State Machine Power Factor Correction 1 - Time Out) Time Out detected yes [-]       1 [s] continuous
absolute value of sensor value jump >= 2 [V/40ms]
AND    
AND     active charging process over Rail 1 yes [-]
Number of occurrences >=3 [-]      
Time Out for charging of the Interlink-Capacitors Rail 2 (State Machine Power Factor Correction 2 - Time Out) Time Out detected yes [-]       1 [s] continuous
absolute value of sensor value jump >= 2 [V/40ms]
AND    
AND     active charging process over Rail 2 yes [-]
Number of occurrences >=3 [-]      
Rail 1 AC-voltage-operating-point not reached (State Machine Power Factor Correction 1 - Time Out) power factor correction-digital signal processor reported that Voltage Slope Rise Time Out occurred for Rail 1 yes [-] ECU is active TRUE [-] 2 [s] continuous
AND    
Number of occurrences >=3 [-]
Rail2 AC-voltage-operating-point not reached (State Machine Power Factor Correction2 - TimeOut) power factor correction-digital signal processor reported that Voltage Slope Rise Time Out occurred for Rail 2 yes [-] ECU is active TRUE [-] 2 [s] continuous
AND    
Number of occurrences >=3 [-]
Capacitor-interlink voltage Rail 1 too low (State Machine Power Factor Correction 1 - Time Out) power factor correction-digital signal processor reported that Interlink-Capacitors for Rail 1 has a voltage of < 380 [V]       2 [s] continuous
active charging process over Rail 1 yes [-]
AND    
AND     for a time of >= 1 [s]
Number of occurrences >=3 [-]      
Capacitor-interlink voltage Rail 2 too low (State Machine Power Factor Correction 2 - Time Out) power factor correction-digital signal processor reported that Interlink-Capacitors for Rail 2 has a voltage of < 380 [V]       2 [s] continuous
active charging process over Rail 2 yes [-]
AND    
AND     for a time of >= 1 [s]
Number of occurrences >=3 [-]      
RAM-Error Power Factor Correction 1 power factor correction-digital signal processor reports RAM-Error Rail 1 yes [-] ECU is active TRUE [-] 1 [s] continuous  
AND    
Number of occurrences >=3 [-]
RAM-Error Power Factor Correction 2 power factor correction-digital signal processor reports RAM-Error Rail 2 yes [-] ECU is active TRUE [-] 1 [s] continuous
AND    
Number of occurrences >=3 [-]
ROM-Error Power Factor Correction 1 power factor correction-digital signal processor reports Flash-Error (ROM) Rail 1 yes [-] ECU is active TRUE [-] 1 [s] continuous
AND    
additional Digital Signal Processor Errors   Number of occurrences >=3 [-]         2 DCY
ROM-Error Power Factor Correction 2 power factor correction-digital signal processor reports Flash-Error (ROM) Rail 2 yes [-] ECU is active TRUE [-] 1 [s] continuous
AND    
Number of occurrences >=3 [-]
Message Time Out Power Factor Correction 1 power factor correction-digital signal processor reported Command-Time Out Rail 1 yes [-] Switched-Mode Power Supply ON [-] 500 [ms] continuous
AND    
Number of occurrences >=3 [-]
Message Time Out Power Factor Correction 2 power factor correction-digital signal processor reported Command-Time Out Rail 2 yes [-] Switched-Mode Power Supply ON [-] 500 [ms] continuous
AND    
Number of occurrences >=3 [-]
Set point-Error Power Factor Correction 1 power factor correction-digital signal processor reported Set point-Error for Rail 1 yes [-] ECU is active TRUE [-] 500 [ms] continuous
AND    
Number of occurrences >=3 [-]
Set point-Error Power Factor Correction 2 power factor correction-digital signal processor reported Set point-Error for Rail 2 yes [-] ECU is active TRUE [-] 500 [ms] continuous
AND    
Number of occurrences >=3 [-]
Set point-Error Rail 1 (DCDC) DCDC-digital signal processor reported Set point-Error for Rail 1 yes [-] ECU is active TRUE [-] 500 [ms] continuous
AND    
Number of occurrences >=3 [-]
Set point-Error Rail 2 (DCDC) DCDC-digital signal processor reported Set point-Error for Rail 2 yes [-] ECU is active TRUE [-] 500 [ms] continuous
AND    
Number of occurrences >=3 [-]
CAN communication U0028 - Vehicle Communication Bus A Hybrid CAN communication check - Bus off Bus Off Detection by Controller yes [-] ECU is active TRUE [-] 500 [ms] continuous 2 DCY
U0029 - Vehicle Communication Bus A Performance Hybrid CAN communication check - Global Time Out Global Time Out Detection yes [-] ECU is active TRUE [-] 450 [ms] continuous 2 DCY
HV-DC voltage sensor P0D20 - Battery Charger "A" Output Voltage Performance HV-DC output voltage too low voltage sensor value < 230 [V] charging current > 0 [A] 1 [s] continuous 2 DCY
HV-DC output voltage too high voltage sensor value > 450 [V] charging mode active [-] 1 [s] continuous
HV-DC current sensor P0D22 - Battery Charger "A" Output Current Performance HV-DC output current Rail 1 too high current sensor value > 12, 5 [A] ECU is active TRUE [-] 1 [s] 2 DCY
HV-DC output current Rail 2 too high current sensor value > 12, 5 [A] ECU is active TRUE [-] 1 [s] continuous
Safety line (local HV interlock) P0D15 - Battery Charging System "A" High Voltage Interlock Circuit/Open Safety line (local HV Interlock) open load LHVIL voltage > 0.77 [V] LHVIL coded yes [-] 50 [ms] continuous 2 DCY
AND    
clamp 30 voltage >= 9 [V]
AND    
AND     clamp 30 voltage <= 16 [V]
LHVIL voltage < 3.77 [V] AND    
System Board temperature >= -40 [°C]
AND    
System Board temperature <= 130 [°C]
Safety line (local HV Interlock) short circuit to ground (SCG) LHVIL voltage < 0.77 [V] LHVIL coded yes [-] 500 [ms] continuous
AND    
clamp 30 voltage >= 9 [V]
AND    
clamp 30 voltage <= 16 [V]
AND    
System Board temperature >= -40 [°C]
AND    
System Board temperature <= 130 [°C]
Safety line (local HV Interlock) short circuit to plus (SCB) LHVIL voltage > 7.73 [V] LHVIL coded yes [-] 500 [ms] continuous
AND    
clamp 30 voltage >= 9 [V]
AND    
clamp 30 voltage <= 16 [V]
        AND        
System Board temperature >= -40 [°C]
AND    
System Board temperature <= 130 [°C]
Proximity Socket Circuit P0D56 - Proximity Detection Circuit "A" Proximity detection open circuit (OC) PRX voltage > 4.778 [V] ECU is active TRUE [-] 4000 [ms] continuous 1DCY
AND    
PRX voltage <= 5.409 [V]
OR
clamp 30 voltage < 8 [V] ECU is active TRUE [-] 14000 [ms]
OR    
clamp 30 voltage > 16 [V]
Proximity Socket Circuit Low P0D58 - Proximity Detection Circuit "A" Low Proximity detection short circuit to ground (SCG) PRX voltage < 0.53 [V] ECU is active TRUE [s] 4000 [ms] continuous 1DCY
Proximity Socket Circuit High P0D59 - Proximity Detection Circuit "A" High Proximity detection short circuit to plus (SCB) PRX voltage > 5.1 [V] ECU is active TRUE [s] 4000 [ms] continuous 1DCY
        AND        
AC plug LOCKED [-]
AND    
for time >= 4 [s]
Control Pilot Circuit P0CF3 - Control Pilot Circuit /Open Control Pilot open circuit (OC) CP voltage < 500 [mV] AC plug NOT PLUGGED [-] 3 [s] continuous 2 DCY
Plug interlock P0D91 - Battery Charger Coupler Lock Control Circuit/Open Plug interlock disconnected Number of locking requests >= 3 [-] for time >= 400 ms 1.2 [s] continuous 2 DCY
AND    
plug lock motor current ==0 [A]
Temperature Sensor Socket AC P0D9B - Battery Charger Coupler Temperature Sensor "A" Circuit Low Charging socket temperature sensor 1 upper limit exceeded (ORH) temperature sensor voltage > 1288 [mV] AC plug PLUGGED [-] 4 [s] continuous 2 DCY
P0D9C - Battery Charger Coupler Temperature Sensor "A" Circuit High Charging socket temperature sensor 1 lower limit exceeded (ORL) temperature sensor voltage < 898 [mV] AC plug PLUGGED [-] 4 [s] continuous 2 DCY
Locking mechanism detection - Socket A (AC) P0DA0 - Battery Charger "A" Coupler Lock Position Sensor Circuit Low Locking mechanism charging socket A short circuit to ground (SCG) Coupler interlock voltage <= 0.3227 [V] ECU is active TRUE [-] 5000 [ms] continuous 2 DCY
Locking mechanism detection - Socket A (AC) P0DA1 - Battery Charger "A" Coupler Lock Position Sensor Circuit High Locking mechanism charging socket A short circuit to plus (SCB) Coupler interlock voltage > clamp 30 voltage * 0.951 [V] ECU is active TRUE [-] 5000 [ms] continuous 2 DCY
Locking mechanism detection - Socket A (AC) P0D9E - Battery Charger "A" Coupler Lock Position Sensor Circuit Locking mechanism charging socket A open circuit (OC) clamp 30 voltage > 16 [V] ECU is active TRUE [s] 15000 [ms] continuous 2 DCY
OR    
clamp 30 voltage < 8 [V]
OR
Coupler interlock voltage =< clamp 30 voltage * 0.951 [V] ECU is active TRUE [-] 5000 [ms] continuous
AND    
Coupler interlock voltage >= clamp 30 voltage * 0.715 [V]
OR
Attempts of requests >= 3 [-] AC plug PLUGGED [-] 10000 [ms] continuous
AND    
plug locking request yes [-]
AND    
Coupler interlock voltage < clamp 30 voltage * 0.512 [V]
OR    
AC plug PLUGGED [-]
AND    
plug locking request yes [-]
AND    
Coupler interlock voltage > clamp 30 voltage * 0.714 [V]
OR    
AC plug PLUGGED [-]
AND    
plug unlocking request yes [-]
AND    
Coupler interlock voltage < clamp 30 voltage * 0.512 [V]
OR    
        AC plug PLUGGED [-]    
AND    
plug unlocking request yes [-]
AND    
Coupler interlock voltage > clamp 30 voltage * 0.714 [V]
P0D9F - Battery Charger "A" Coupler Lock Position Sensor Circuit Range/Performance Locking mechanism charging socket A implausible value (RAT) Coupler interlock voltage <0 [V] ECU is active TRUE [-] 5000 [ms] continuous 2 DCY
OR    
Coupler interlock voltage >= clamp 30 voltage * 0.031 [V]
AND    
Coupler interlock voltage <= clamp 30 voltage * 0.127 [V]
OR    
Coupler interlock voltage >= clamp 30 voltage * 0.21 [V]
AND    
Coupler interlock voltage <= clamp 30 voltage * 0.512 [V]
OR    
Coupler interlock voltage >= clamp 30 voltage * 0.714 [V]
AND    
Coupler interlock voltage <= clamp 30 voltage * 0.715 [V]
CAN Time Out U0111 - Lost Communication With Battery Energy Control Module "A" Lost communication with BECM control module CAN Message Time Out DETECTED [-] ECU is active TRUE [-] 5 [s] continuous 2 DCY
U0122 - Lost Communication With Vehicle Dynamics Control Module Lost communication with BSCM control module CAN Message Time Out DETECTED [-] Clamp 15 on [-] 2 [s] continuous 2 DCY
CAN Value Error BSCM communication value error invalid message content DETECTED [-] Clamp 15 on [-] 2 [s] continuous 2 DCY
CAN Time Out U0100 - Lost Communication With ECM/PCM "A" Lost communication with ECM control module CAN Message Time Out DETECTED [-] ECU is active TRUE [-] 5 [s] continuous 2 DCY
CAN Value Error U0412 - Invalid Data Received From Battery Energy Control Module "A" BECM communication value error invalid message content DETECTED [-] ECU is active TRUE [-] 5 [s] continuous 2 DCY
AC infrastructure P0D67 - Battery Charger Control Module "A" Performance Over current L1 Number of occurrences > 5 [-] Charging mode active [-] 1 [s] continuous 2 DCY
AND    
AC current sensor value > max. AC current +1.6 [A]
Temperature sensor Power Factor Correction 1 Temperature sensor Power Factor Correction 1 upper limit exceeded ( Temperature > 130 [°C] ECU is active TRUE [-] 1 [s] continuous 2 DCY
Temperature sensor Power Factor Correction 1 lower limit exceeded (ORL) Temperature < -50 [°C] ECU is active TRUE [-] 1 [s] continuous
Temperature sensor Power Factor Correction 2 Temperature sensor Power Factor Correction 2 upper limit exceeded ( Temperature > 130 [°C] ECU is active TRUE [-] 1 [s] continuous 2 DCY
Temperature sensor Power Factor Correction 2 lower limit exceeded (ORL) Temperature < -50 [°C] ECU is active TRUE [-] 1 [s] continuous
FuSi error Intervention by LMSF Functional safety error DETECTED [-] ECU is active TRUE [-] 500 [ms] continuous 2 DCY