| Supply voltage sensor |
P0E5E - Battery Charger Control Module "A" Processor Performance |
Supply voltage sensor upper limit exceeded (ORH) |
supply voltage sensor value |
>23 |
[V] |
ECU is active |
TRUE |
[-] |
2 [s] continuous |
2 DCY |
| Supply voltage restriction due to under voltage |
supply voltage sensor value |
<=9 |
[V] |
ECU is active |
TRUE |
[-] |
5 [s] continuous |
| Supply voltage restriction due to over voltage |
supply voltage sensor value |
>=16 |
[V] |
ECU is active |
TRUE |
[-] |
5 [s] continuous |
| Supply voltage lower limit exceeded (ORL) |
supply voltage sensor value |
<=9 |
[V] |
ECU is active |
TRUE |
[-] |
90 [s] continuous |
| Supply voltage upper limit exceeded (ORH) |
supply voltage sensor value |
>=16 |
[V] |
ECU is active |
TRUE |
[-] |
90 [s] continuous |
| Supply voltage sensor lower limit exceeded (ORL) |
supply voltage sensor value |
<= 2.5 |
[V] |
ECU is active |
TRUE |
[-] |
2 [s] continuous |
| Supply voltage sensor implausible value (RAT) |
plug interlock voltage sensor value |
> 0.65 * U_Batt |
[V] |
|
5 [s] continuous |
| OR |
|
|
| plug interlock voltage sensor value |
< 0.36 * U_Batt |
[V] |
car velocity |
> 0 |
[mph] |
| AND |
|
|
AND |
|
|
| plug interlock voltage sensor value |
> 0.23 * U_Batt |
[V] |
for time |
>= 30 |
[s] |
| OR |
|
|
|
| plug interlock voltage sensor value |
< 0.05 * U_Batt |
[V] |
| HV-DC voltage sensor 1 |
HV-DC voltage sensor 1 upper limit exceeded (ORH) |
HV-DC voltage sensor value |
> 654.3 |
[V] |
ECU is active |
TRUE |
[-] |
4 [s] continuous |
2 DCY |
| AND |
|
|
| HV-DC voltage sensor value |
<= 690.6 |
[V] |
| HV-DC voltage sensor 1 short circuit to ground (SCG) |
HV-DC voltage sensor value |
< -43.6 |
[V] |
ECU is active |
TRUE |
[-] |
4 [s] continuous |
| HV-DC voltage sensor 1 short circuit to plus (SCB) |
HV-DC voltage sensor value |
> 690.6 |
[V] |
ECU is active |
TRUE |
[-] |
4 [s] continuous |
| HV-DC voltage sensor 1 lower limit exceeded (ORL) |
HV-DC voltage sensor value |
< -16.4 |
[V] |
ECU is active |
TRUE |
[-] |
4 [s] continuous |
| AND |
|
|
| HV-DC voltage sensor value |
>= -43.6 |
[V] |
| HV-DC voltage sensor 1 erratic |
Occurrence frequency |
>= 20 |
[1/10sec] |
absolute value of sensor value jump |
>= 50 |
[V/sec] |
30 [s] continuous |
| HV-DC voltage sensor 2 |
HV-DC voltage sensor 2 lower limit exceeded (ORL) |
HV-DC voltage sensor value |
< -16.4 |
[V] |
ECU is active |
TRUE |
[-] |
4 [s] continuous |
2 DCY |
| AND |
|
|
| HV-DC voltage sensor value |
>= -43.6 |
[V] |
| HV-DC voltage sensor 2 upper limit exceeded (ORH) |
HV-DC voltage sensor value |
> 654.3 |
[V] |
ECU is active |
TRUE |
[-] |
4 [s] continuous |
| AND |
|
|
| HV-DC voltage sensor value |
<= 690.6 |
[V] |
| HV-DC voltage sensor 2 short circuit to ground (SCG) |
DC voltage |
< -43.6 |
[V] |
ECU is active |
TRUE |
[-] |
4 [s] continuous |
| HV-DC voltage sensor 2 short circuit to plus (SCB) |
DC voltage |
> 690.6 |
[V] |
ECU is active |
TRUE |
[-] |
4 [s] continuous |
| HV-DC voltage sensor 2 erratic |
Occurrence frequency |
>= 20 |
[1/10 sec] |
absolute value of sensor value jump |
>= 50 |
[V/sec] |
30 [s] continuous |
| HV-DC voltage sensor 3 |
HV-DC voltage sensor 3 lower limit exceeded (ORL) |
HV-DC voltage sensor value |
< -19.4 |
[V] |
ECU is active |
TRUE |
[-] |
4 [s] continuous |
2 DCY |
| AND |
|
|
| HV-DC voltage sensor value |
>= -23.8 |
[V] |
| HV-DC voltage sensor 3 short circuit to ground (SCG) |
DC voltage |
< -23.8 |
[V] |
ECU is active |
TRUE |
[-] |
4 [s] continuous |
| HV-DC voltage sensor 3 erratic |
Occurrence frequency |
>= 20 |
[1/10 sec] |
absolute value of sensor value jump |
>= 50 |
[V/sec] |
30 [s] continuous |
| HV-DC voltage sensor |
HV-DC voltage sensor implausible value (RAT) |
absolute value of difference between HV-DC voltage sensor 1 and sensor 2 values |
> 40 |
[V] |
ECU is active |
TRUE |
[-] |
4 [s] continuous |
2 DCY |
| DCDC supply voltage |
DCDC supply voltage sensor short circuit to plus (SCB) |
DCDC supply voltage sensor value |
> 36.3 |
[V] |
ECU is active |
TRUE |
[-] |
1 [s] continuous |
2 DCY |
| DCDC supply voltage sensor short circuit to ground (SCG) |
DCDC supply voltage sensor value |
< 0.3 |
[V] |
ECU is active |
TRUE |
[-] |
1 [s] continuous |
| DCDC supply voltage sensor upper limit exceeded (ORH) |
DCDC supply voltage sensor value |
> 36.2 |
[V] |
ECU is active |
TRUE |
[-] |
1 [s] continuous |
| AND |
|
|
| DCDC supply voltage sensor value |
<= 36.3 |
[V] |
| DCDC supply voltage sensor lower limit exceeded (ORL) |
DCDC supply voltage sensor value |
< 1.3 |
[V] |
ECU is active |
TRUE |
[-] |
1 [s] continuous |
| AND |
|
|
| DCDC supply voltage sensor value |
>= 0.3 |
[V] |
| |
Communication to DCDC-digital signal processor |
on |
[-] |
|
|
|
1 [s] |
| DCDC supply voltage sensor implausible value (RAT) |
AND |
|
|
ECU is active |
TRUE |
[-] |
continuous |
|
| DCDC-digital signal processor supply voltage sensor value |
< 2 |
[V] |
| DCDC supply voltage sensor erratic |
Occurrence frequency |
>= 16 |
[1/10 sec] |
absolute value of sensor value jump |
>= 4 |
[V/sec] |
30 [s] continuous |
| 3.3 V supply voltage |
3.3 V supply voltage sensor short circuit to ground (SCG) |
3v3_power_supply voltage sensor value |
< 1.6 |
[V] |
system reset |
yes |
[-] |
1 [s] continuous |
2 DCY |
| 3.3 V supply voltage sensor upper limit exceeded (ORH) |
3v3_power_supply voltage sensor value |
> 3.4 |
[V] |
system reset |
yes |
[-] |
1 [s] continuous |
| 3.3 V supply voltage sensor lower limit exceeded (ORL) |
3v3_power_supply voltage sensor value |
< 3.2 |
[V] |
system reset |
yes |
[-] |
1 [s] continuous |
| 3.3 V supply voltage sensor erratic |
Occurrence frequency |
>= 16 |
[1/10 sec] |
absolute value of sensor value jump |
>= 1 |
[V/sec] |
30 [s] continuous |
| DCDC input current |
DCDC input current Rail 1 too high (over current shutoff) |
DCDC-digital signal processor detected a Rail1 DC-over current (HW) - Stage 2 of |
> 67.4 |
[A] |
Charging mode |
active |
[-] |
1 [s] continuous |
2 DCY |
| AND |
|
|
| Number of occurrences |
>=3 |
[-] |
| DCDC input current Rail 2 too high (over current shutoff) |
DCDC-digital signal processor detected a Rail 2 DC-Over current (HW) - Stage 2 of |
> 67.4 |
[A] |
Charging mode |
active |
[-] |
1 [s] continuous |
| AND |
|
|
| Number of occurrences |
>=3 |
[-] |
| Temperature sensor coolant |
Temperature sensor coolant upper limit exceeded (ORH) |
temperature sensor value |
> 130 |
[°C] |
ECU is active |
TRUE |
[-] |
1 [s] |
2 DCY |
| Temperature sensor coolant lower limit exceeded (ORL) |
temperature sensor value |
< -40 |
[°C] |
ECU is active |
TRUE |
[-] |
1 [s] continuous |
| Temperature sensor coolant implausible value (RAT) |
absolute value of the difference between temperature of the DCDC coil and coolant temperature |
> 15 |
[°C] |
car velocity |
> 0 |
[mph] |
30 [s] once per driving cycle |
| AND |
|
|
| for time |
>= 10 |
[min] |
| Temperature sensor coolant over temperature |
temperature sensor value |
> 100 |
[°C] |
for time |
5 |
[min] |
1 [s] |
| Temperature sensor coolant erratic |
Occurrence frequency |
>=10 |
[1/h] |
absolute value of sensor value jump |
>= 20 |
[K/sec] |
1 [h] continuous |
| Temperature sensor signal electronics |
Temperature sensor signal electronics lower limit exceeded (ORL) |
temperature sensor value |
< -45 |
[°C] |
ECU is active |
TRUE |
[-] |
1 [s] continuous |
2 DCY |
| Temperature sensor signal electronics upper limit exceeded (ORH) |
temperature sensor value |
> 150 |
[°C] |
ECU is active |
TRUE |
[-] |
1 [s] continuous |
| Temperature sensor signal electronics implausible value (RAT) |
absolute value of the difference between temperature of the Printed Circuit Board temperature sensor and coolant temperature |
> 55 |
[°C] |
ECU is active |
TRUE |
[-] |
61 [s] continuous |
| Temperature sensor signal electronics erratic |
Occurrence frequency |
>=10 |
[1/h] |
absolute value of sensor value jump |
>= 20 |
[K/sec] |
1 [h] continuous |
| Temperature sensor Power Factor Correction 1 |
Temperature sensor Power Factor Correction 1 implausible value (RAT) |
absolute difference with two or more other digital signal processor sensors |
> 50 |
[°C] |
ECU is active |
TRUE |
[-] |
1 [s] continuous |
2 DCY |
| Temperature sensor Power Factor Correction 1 erratic |
Occurrence frequency |
>=10 |
[1/h] |
absolute value of sensor value jump |
>= 20 |
[K/s] |
1 [h] continuous |
| Temperature sensor Power Factor Correction 2 |
Temperature sensor Power Factor Correction 2 implausible value (RAT) |
absolute difference with two or more other digital signal processor sensors |
> 50 |
[°C] |
ECU is active |
TRUE |
[-] |
1 [s] continuous |
2 DCY |
| Temperature sensor Power Factor Correction 2 erratic |
Occurrence frequency |
>=10 |
[1/h] |
absolute value of sensor value jump |
>= 20 |
[K/sec] |
1 [h] continuous |
| Temperature sensor DCDC 1 |
Temperature sensor DCDC 1 upper limit exceeded (ORH) |
temperature sensor value |
> 130 |
[°C] |
ECU is active |
TRUE |
[-] |
1 [s] continuous |
2 DCY |
| Temperature sensor DCDC 1 lower limit exceeded (ORL) |
temperature sensor value |
< -50 |
[°C] |
ECU is active |
TRUE |
[-] |
1 [s] continuous |
| Temperature sensor DCDC 1 implausible value (RAT) |
absolute difference with two or more other digital signal processor sensors |
> 50 |
[°C] |
ECU is active |
TRUE |
[-] |
1 [s] continuous |
| Temperature sensor DCDC 1 erratic |
Occurrence frequency |
>=10 |
[1/h] |
absolute value of sensor value jump |
>= 20 |
[K/sec] |
1 [h] continuous |
| Temperature sensor DCDC 2 |
Temperature sensor DCDC 2 upper limit exceeded (ORH) |
temperature sensor value |
> 130 |
[°C] |
ECU is active |
TRUE |
[-] |
1 [s] continuous |
2 DCY |
| Temperature sensor DCDC 2 lower limit exceeded (ORL) |
temperature sensor value |
< -50 |
[°C] |
ECU is active |
TRUE |
[-] |
1 [s] continuous |
| Temperature sensor DCDC 2 implausible value (RAT) |
Difference with two or more other digital signal processor sensors |
> 50 |
[°C] |
ECU is active |
TRUE |
[-] |
1 [s] continuous |
| Temperature sensor DCDC 2 erratic |
Occurrence frequency |
>=10 |
[1/h] |
absolute value of sensor value jump |
>= 20 |
[K/sec] |
1 [h] continuous |
| |
|
|
|
LHVIL coded |
yes |
[-] |
|
|
| AND |
|
|
| Safety line (local HV interlock) |
Safety line (local HV Interlock) evaluation defect |
Error in evaluation function |
detected |
[-] |
clamp 30 Voltage |
>= 9 |
[V] |
500 [ms] continuous |
2 DCY |
| AND |
|
|
| clamp 30 Voltage |
<= 16 |
[V] |
| AND |
|
|
| System Board temperature |
>= -40 |
[°C] |
| AND |
|
|
| System Board temperature |
<= 130 |
[°C] |
| S2 |
S2 malfunction |
S2 state |
closed |
[-] |
ECU is active |
TRUE |
[-] |
2 [s] continuous |
2 DCY |
| AND |
|
|
| CP voltage |
> 7 |
[V] |
| OR |
|
|
| S2 state |
closed |
[-] |
| AND |
|
|
| CP voltage |
< 5 |
[V] |
| OR |
|
|
| S2 state |
open |
[-] |
| AND |
|
|
| CP voltage |
> 10 |
[V] |
| OR |
|
|
| S2 state |
open |
[-] |
| AND |
|
|
| CP voltage |
< 8 |
[V] |
| Relay |
Readback control phase switching 1 short circuit to plus (SCB) |
sensor value |
> 25.7 |
[V] |
ECU is active |
TRUE |
[-] |
1 [s] continuous |
2 DCY |
| Readback control phase switching 1 short circuit to ground (SCG) |
sensor value |
< 0.3 |
[V] |
ECU is active |
TRUE |
[-] |
1 [s] continuous |
| Readback control phase switching 1 upper limit exceeded (ORH) |
sensor value |
> 25.4 |
[V] |
ECU is active |
TRUE |
[-] |
1 [s] continuous |
| AND |
|
|
| sensor value |
<= 25.7 |
[V] |
| Readback control phase switching 1 lower limit exceeded (ORL) |
sensor value |
< 1.3 |
[V] |
ECU is active |
TRUE |
[-] |
1 [s] continuous |
| AND |
|
|
| sensor value |
>= 0.3 |
[V] |
| Relay phase switching 1 stuck open |
Power Factor Correction - Digital Signal Processor reports relay phase error on rail 2 |
yes |
[-] |
charge release is given |
yes |
[-] |
500 [ms] continuous |
| AND |
|
|
| Number of occurrences |
>=3 |
[-] |
| DCDC Digital Signal Processor |
Undefined state of the State Machine DCDC |
DCDC-digital signal processor state-machine is in undefined state |
yes |
[-] |
ECU is active |
TRUE |
[-] |
1 [s] continuous |
2 DCY |
| AND |
|
|
| Number of occurrences |
>=3 |
[-] |
| RAM-Error DCDC |
DCDC-digital signal processor reports RAM- Error |
yes |
[-] |
ECU is active |
TRUE |
[-] |
1 [s] continuous |
| AND |
|
|
| Number of occurrences |
>=3 |
[-] |
| ROM-Error DCDC |
DCDC-digital signal processor reports Flash- |
yes |
[-] |
ECU is active |
TRUE |
[-] |
1 [s] continuous |
| AND |
|
|
| Number of occurrences |
>=3 |
[-] |
| Control unit defect |
Check of RAM buffer failed |
RAM buffer error |
detected |
[-] |
ECU is active |
TRUE |
[-] |
1 [s] continuous |
2 DCY |
| Check sum of ROM areas failed |
check sum error |
detected |
[-] |
ECU is active |
TRUE |
[-] |
1 [s] continuous |
| Defective EEPROM memory |
read job |
failed |
[-] |
EEPROM memory diagnosis |
yes |
[-] |
1 [s] once per driving cycle |
| OR |
|
|
| write job |
failed |
[-] |
| OR |
|
|
| compare job |
failed |
[-] |
| OR |
|
|
| communication test job |
failed |
[-] |
| OR |
|
|
| erase job |
failed |
[-] |
| OR |
|
|
| unlock job |
failed |
[-] |
| Defective DataFlash memory |
erase job |
failed |
[-] |
DataFlash memory diagnosis |
yes |
[-] |
1 [s] once per driving cycle |
| OR |
|
|
| read job |
failed |
[-] |
| OR |
|
|
| write job |
failed |
[-] |
| OR |
|
|
| compare job |
failed |
[-] |
| Control unit defective Watchdog error |
Watchdog error |
detected |
[-] |
ECU is active |
TRUE |
[-] |
1 [s] continuous |
| Controller internal communication error |
Internal communication error |
detected |
[-] |
ECU is active |
TRUE |
[-] |
90 [s] continuous |
| |
Digital Signal Processor error detected |
yes |
[-] |
Charging mode |
active |
[-] |
1 [s] |
| Control unit internal counter error |
AND |
|
|
OR |
|
|
continuous |
|
| Number of occurrences |
>=5 |
[-] |
Charging mode |
requested |
[-] |
| AD-Unit-1 Check: upper limit exceeded (ORH) |
any ADC measured value |
> 783 |
[digits] |
ECU is active |
TRUE |
[-] |
1 [s] continuous |
| AD-Unit-1 Check: lower limit exceeded (ORL) |
any ADC measured value |
< 241 |
[digits] |
ECU is active |
TRUE |
[-] |
1 [s] continuous |
| Error software coding variant system |
Reference resistor does not match any voltage range to derive variants (HW-Sample Version, Power-Class) from it |
yes |
[-] |
ECU is active |
TRUE |
[-] |
1 [s] continuous |
| Error while shutdown |
Error counter |
>=2 |
[-] |
ECU is active |
TRUE |
[-] |
1 [s] continuous |
| Secure Boot error |
Error in Secure Boot |
detected |
[-] |
ECU is active |
TRUE |
[-] |
1 [s] continuous |
| Coding |
Variant coding DCDC Digital Signal Processor defective |
EcuHWNumber[10] |
== 'A' |
|
ECU is active |
TRUE |
[-] |
1 [s] continuous |
2 DCY |
| OR |
|
|
| EcuHWNumber[10] |
== 'Q' |
|
| AND |
|
|
| DCDC-digital signal processor reports detected Voltage-Variant |
== 800 |
[V] |
| Program coding Power Factor Correction Digital Signal Processor defective |
Unexpected software coding detected |
yes |
[-] |
ECU is active |
TRUE |
[-] |
1 [s] continuous |
2 DCY |
| Program coding DCDC Digital Signal Processor defective |
Unexpected software coding detected |
yes |
[-] |
ECU is active |
TRUE |
[-] |
1 [s] continuous |
2 DCY |
| OBD Monitoring |
P0D5C - Battery Charger Hybrid/EV Battery Output Power Performance |
Efficiency too low |
efficiency |
< 80 |
[%] |
active charging |
yes |
[-] |
60 [s] continuous |
2 DCY |
| AND |
|
|
| input power |
> 1000 |
[W] |
| Temperature sensor coolant |
P0D24 - Battery Charger "A" Temperature Too High |
Shutdown due to over temperature temperature sensor coolant inlet |
temperature sensor value |
> 80 |
[°C] |
ECU is active |
TRUE |
[-] |
1 [s] continuous |
2 DCY |
| Temperature sensor signal electronics |
Shutdown due to over temperature temperature sensor signal electronics |
temperature sensor value |
> 130 |
[°C] |
Charging mode |
active |
[-] |
1 [s] continuous |
2 DCY |
| Temperature sensor Power Factor Correction 1 |
Shutdown due to over temperature temperature sensor Power Factor Correction 1 |
temperature sensor value |
> 130 |
[°C] |
Charging mode |
active |
[-] |
1 [s] continuous |
2 DCY |
| AND |
|
|
| Number of occurrences |
>=3 |
[-] |
| Temperature sensor Power Factor Correction 2 |
Shutdown due to over temperature temperature sensor Power Factor Correction 2 |
temperature sensor value |
> 130 |
[°C] |
Charging mode |
active |
[-] |
1 [s] continuous |
2 DCY |
| AND |
|
|
| Number of occurrences |
>=3 |
[-] |
| Temperature sensor DCDC 1 |
Shutdown due to over temperature temperature sensor DCDC 1 |
temperature sensor value |
> 130 |
[°C] |
Charging mode |
active |
[-] |
1 [s] continuous |
2 DCY |
| AND |
|
|
| Number of occurrences |
>=3 |
[-] |
| Temperature sensor DCDC 2 |
Shutdown due to over temperature temperature sensor DCDC 2 |
temperature sensor value |
> 130 |
[°C] |
Charging mode |
active |
[-] |
1 [s] continuous |
2 DCY |
| AND |
|
|
| Number of occurrences |
>=3 |
[-] |
| Coding |
U0337 - Software Incompatibility with Battery Charger Control Module "A" |
Monitoring of invalid coding value |
invalid coding value detected |
yes |
[-] |
ECU is active |
TRUE |
[-] |
100 [ms] continuous |
1DCY |
| Dataset Download |
Invalid dataset |
invalid data detected |
yes |
[-] |
RAM check successful |
yes |
[-] |
100 [ms] continuous |
1DCY |
| AND |
|
|
| ROM check successful |
yes |
[-] |
| Monitoring of implausible dataset |
implausible data detected |
yes |
[-] |
RAM check successful |
yes |
[-] |
100 [ms] continuous |
1DCY |
| AND |
|
|
| ROM check successful |
yes |
[-] |
| Production mode |
Production mode active |
production mode |
active |
[-] |
ECU is active |
TRUE |
[-] |
100 [ms] continuous |
1DCY |
| Charging flap lock |
Charging flap locked due to workshop mode |
Charging flap locking request |
yes |
[-] |
ECU is active |
TRUE |
[-] |
100 [ms] continuous |
1DCY |
| Temperature Sensor Socket AC |
P0D99 - Battery Charger Coupler Temperature Sensor "A" Circuit |
Charging socket AC temperature sensor erratic |
Occurrence frequency |
>=10 |
[1/h] |
absolute value of sensor value jump |
>= 20 |
[K/sec] |
1 [h] continuous |
2 DCY |
| Temperature Socket AC |
P0E5F - Battery Charger Coupler Temperature "A" Too High |
Charging socket AC over temperature |
temperature sensor value |
>= 80 |
[°C] |
AC plug |
PLUGGED |
[-] |
5 [s] continuous |
2 DCY |
| AC voltage sensor L1 |
P0D67 - Battery Charger Control Module "A" Performance |
AC voltage sensor L1 upper limit exceeded (ORH) |
voltage sensor value |
> 482.4 |
[V] |
ECU is active |
TRUE |
[-] |
4 [s] continuous |
2 DCY |
| AND |
|
|
| voltage sensor value |
<= 494.8 |
[V] |
| AC voltage sensor L1 short circuit to ground (SCG) |
voltage sensor value |
< -482.9 |
[V] |
ECU is active |
TRUE |
[-] |
4 [s] continuous |
| AC voltage sensor L1 short circuit to plus (SCB) |
voltage sensor value |
> 494.8 |
[V] |
ECU is active |
TRUE |
[-] |
|
| AC voltage sensor L1 lower limit exceeded (ORL) |
voltage sensor value |
< -446.7 |
[V] |
ECU is active |
TRUE |
[-] |
4 [s] continuous |
| AND |
|
|
| voltage sensor value |
>= -482.9 |
[V] |
| AC voltage sensor L1 implausible value (RAT) |
AC-Voltage |
> 50 |
[V] |
car velocity |
> 3.1 |
[mph] |
4 [s] continuous |
| AC voltage sensor L2 upper limit exceeded (ORH) |
voltage sensor value |
> 482.4 |
[V] |
ECU is active |
TRUE |
[-] |
4 [s] continuous |
|
| AND |
|
|
| voltage sensor value |
<= 494.8 |
[V] |
| AC voltage sensor L2 |
AC voltage sensor L2 short circuit to ground (SCG) |
voltage sensor value |
< -482.9 |
[V] |
ECU is active |
TRUE |
[-] |
4 [s] continuous |
2 DCY |
| AC voltage sensor L2 short circuit to plus (SCB) |
voltage sensor value |
> 494.8 |
[V] |
ECU is active |
TRUE |
[-] |
4 [s] continuous |
| AC voltage sensor L2 lower limit exceeded (ORL) |
voltage sensor value |
< -446.7 |
[V] |
ECU is active |
TRUE |
[-] |
4 [s] continuous |
| AND |
|
|
| voltage sensor value |
>= 482.9 |
[V] |
| AC voltage sensor L2 implausible value (RAT) |
AC-Voltage |
> 50 |
[V] |
car velocity |
> 3.1 |
[mph] |
4 [s] continuous |
| Power Transmission |
Power-Overload Rail 1 (DCDC) |
DCDC-digital signal processor detected an HV Power-Overload for Rail 1 of |
> 3.96 |
[kW] |
active charging process over Rail1 |
yes |
[-] |
1 [s] continuous |
2 DCY |
| AND |
|
|
AND |
|
|
| Number of occurrences |
>=3 |
[-] |
for a time of |
>10 |
[s] |
| Power-Overload Rail 2 (DCDC) |
DCDC-digital signal processor detected an HV Power-Overload for Rail 2 of |
> 3.96 |
[kW] |
active charging process over Rail2 |
yes |
[-] |
1 [s] continuous |
| AND |
|
|
AND |
|
|
| Number of occurrences |
>=3 |
[-] |
for a time of |
>10 |
[s] |
| DC link voltage sensor Rail 1 |
Voltage measurement DC-link Rail1 short circuit to plus (SCB) |
DC link voltage sensor value |
> 546.1 |
[V] |
ECU is active |
TRUE |
[-] |
1 [s] continuous |
2 DCY |
| Voltage measurement DC-link Rail 1 short circuit to ground (SCG) |
DC link voltage sensor value |
< -38.1 |
[V] |
ECU is active |
TRUE |
[-] |
1 [s] continuous |
| Voltage measurement DC-link Rail 1 upper limit exceeded (ORH) |
DC link voltage sensor value |
> 538.8 |
[V] |
|
TRUE |
[-] |
1 [s] continuous |
| AND |
|
|
|
TRUE |
[-] |
| DC link voltage sensor value |
<= 546.1 |
[V] |
ECU is active |
TRUE |
[-] |
| Voltage measurement DC-link Rail 1 lower limit exceeded (ORL) |
DC link voltage sensor value |
< -13.5 |
[V] |
ECU is active |
TRUE |
[-] |
1 [s] continuous |
| AND |
|
|
| DC link voltage sensor value |
>= -38.1 |
[V] |
| Voltage measurement DC-link Rail 1 implausible value (RAT) |
absolute value of difference between DC link voltage and AC peak voltage |
> 30 |
[V] |
ECU is active |
TRUE |
[-] |
1 [s] continuous |
| AND |
|
|
| Number of occurrences |
>=3 |
[-] |
| Fast voltage measurement DC-link Rail 1 implausible value (RAT) |
Deviation between interlink voltages |
> 50 |
[V] |
ECU is active |
TRUE |
[-] |
300 [s] continuous |
| DC link over voltage Rail 1 |
Over voltage shutoff DC-link Rail 1 |
power factor correction-digital signal processor detected a Rail 1 interlink over voltage - stage 2 of |
> 432 |
[V] |
ECU is active |
TRUE |
[-] |
500 [ms] continuous |
2 DCY |
| AND |
|
|
| Number of occurrences |
>=3 |
[-] |
| DC link voltage sensor Rail 2 |
Voltage measurement DC-link Rail 2 short circuit to plus (SCB) |
DC link voltage sensor value |
> 546.1 |
[V] |
ECU is active |
TRUE |
[-] |
1 [s] continuous |
2 DCY |
| Voltage measurement DC-link Rail 2 short circuit to ground (SCG) |
DC link voltage sensor value |
< -38.1 |
[V] |
ECU is active |
TRUE |
[-] |
1 [s] continuous |
| Voltage measurement DC-link Rail 2 upper limit exceeded (ORH) |
DC link voltage sensor value |
> 538.8 |
[V] |
ECU is active |
TRUE |
[-] |
1 [s] continuous |
| AND |
|
|
| DC link voltage sensor value |
<= 546.1 |
[V] |
| Voltage measurement DC-link Rail 2 lower limit exceeded (ORL) |
DC link voltage sensor value |
< -13.5 |
[V] |
ECU is active |
TRUE |
[-] |
1 [s] continuous |
| AND |
|
|
| DC link voltage sensor value |
>= -38.1 |
[V] |
| Voltage measurement DC-link Rail 2 implausible value (RAT) |
absolute value of difference between DC link voltage and AC peak voltage |
> 30 |
[V] |
ECU is active |
TRUE |
[-] |
1 [s] continuous |
| AND |
|
|
| Number of occurrences |
>=3 |
[-] |
| Fast voltage measurement DC-link Rail 2 implausible value (RAT) |
Deviation between interlink voltages |
> 50 |
[V] |
ECU is active |
TRUE |
[-] |
300 [s] continuous |
| DC link over voltage Rail 2 |
Over voltage shutoff DC-link Rail 2 |
power factor correction-digital signal processor detected a Rail 2 interlink over voltage - stage 2 of |
> 432 |
[V] |
ECU is active |
TRUE |
[-] |
500 [ms] continuous |
2 DCY |
| AND |
|
|
| Number of occurrences |
>=3 |
[-] |
| Fast voltage measurement DC link voltage sensor |
Fast voltage measurement DC-link Rail 1 short circuit to plus (SCB) |
DC link voltage sensor value |
> 546.1 |
[V] |
ECU is active |
TRUE |
[-] |
1 [s] continuous |
2 DCY |
| Fast voltage measurement DC-link Rail 2 short circuit to plus (SCB) |
DC link voltage sensor value |
> 546.1 |
[V] |
ECU is active |
TRUE |
[-] |
1 [s] continuous |
| Fast voltage measurement DC-link Rail 1 short circuit to ground (SCG) |
DC link voltage sensor value |
< -38.1 |
[V] |
ECU is active |
TRUE |
[-] |
1 [s] continuous |
| Fast voltage measurement DC-link Rail 2 short circuit to ground (SCG) |
DC link voltage sensor value |
< -38.1 |
[V] |
ECU is active |
TRUE |
[-] |
1 [s] continuous |
| Fast voltage measurement DC-link Rail 1 upper limit exceeded (ORH) |
DC link voltage sensor value |
> 538.8 |
[V] |
ECU is active |
TRUE |
[-] |
1 [s] continuous |
| AND |
|
|
| DC link voltage sensor value |
<= 546.1 |
[V] |
| Fast voltage measurement DC-link Rail 2 upper limit exceeded (ORH) |
DC link voltage sensor value |
> 538.8 |
[V] |
ECU is active |
TRUE |
[-] |
1 [s] continuous |
|
| AND |
|
|
| DC link voltage sensor value |
<= 546.1 |
[V] |
| Fast voltage measurement DC-link Rail 1 lower limit exceeded (ORL) |
DC link voltage sensor value |
< -13.5 |
[V] |
ECU is active |
TRUE |
[-] |
1 [s] continuous |
| AND |
|
|
| DC link voltage sensor value |
>= -38.1 |
[V] |
| Fast voltage measurement DC-link Rail 2 lower limit exceeded (ORL) |
DC link voltage sensor value |
< -13.5 |
[V] |
ECU is active |
TRUE |
[-] |
1 [s] continuous |
| AND |
|
|
| DC link voltage sensor value |
>= -38.1 |
[V] |
| Power Factor Correction Gate driver voltage sensor Rail 1 |
Power Factor Correction 1 Gate driver voltage sensor short circuit to plus (SCB) |
power factor correction gate driver voltage |
> 25.7 |
[V] |
ECU is active |
TRUE |
[-] |
1 [s] continuous |
2 DCY |
| Power Factor Correction 1 Gate driver voltage sensor short circuit to ground (SCG) |
power factor correction gate driver voltage |
< 0.3 |
[V] |
ECU is active |
TRUE |
[-] |
1 [s] continuous |
| Power Factor Correction 1 Gate driver voltage sensor upper limit exceeded (ORH) |
voltage sensor value |
> 25.4 |
[V] |
ECU is active |
TRUE |
[-] |
1 [s] continuous |
| AND |
|
|
| voltage sensor value |
<= 25.7 |
[V] |
| Power Factor Correction 1 Gate driver voltage sensor lower limit exceeded (ORL) |
voltage sensor value |
< 6.3 |
[V] |
ECU is active |
TRUE |
[-] |
1 [s] continuous |
| AND |
|
|
| voltage sensor value |
>= 0.3 |
[V] |
| Power Factor Correction 1 Gate driver voltage sensor implausible value (RAT) |
Gate driver of respective power factor correction-digital signal processor Rail 1 |
off |
[-] |
ECU is active |
TRUE |
[-] |
1 [s] continuous |
| AND |
|
|
| voltage sensor value |
> 6 |
[V] |
| Power Factor Correction 1 Gate driver voltage sensor erratic |
Occurrence frequency |
>= 16 |
[1/10 sec] |
absolute value of sensor value jump |
>= 4 |
[V/sec] |
30 [s] continuous |
| Power Factor Correction supply voltage Rail 1 |
Power Factor Correction 1 supply voltage sensor short circuit to plus (SCB) |
power factor correction gate driver voltage |
> 36.3 |
[V] |
ECU is active |
TRUE |
[-] |
1 [s] continuous |
2 DCY |
| Power Factor Correction 1 supply voltage sensor short circuit to ground (SCG) |
power factor correction gate driver voltage |
< 0.4 |
[V] |
ECU is active |
TRUE |
[-] |
1 [s] continuous |
| Power Factor Correction 1 supply voltage sensor upper limit exceeded (ORH) |
voltage sensor value |
> 35.8 |
[V] |
ECU is active |
TRUE |
[-] |
1 [s] continuous |
| AND |
|
|
| voltage sensor value |
<= 36.3 |
[V] |
| Power Factor Correction 1 supply voltage sensor lower limit exceeded (ORL) |
voltage sensor value |
< 1.8 |
[V] |
ECU is active |
TRUE |
[-] |
1 [s] continuous |
| AND |
|
|
| voltage sensor value |
>= 0.4 |
[V] |
| Power Factor Correction 1 supply voltage sensor implausible value (RAT) |
Communication to power factor correction- digital signal processor |
on |
[-] |
ECU is active |
TRUE |
[-] |
1 [s] continuous |
| AND |
|
|
| voltage sensor value |
< 2 |
[V] |
| Power Factor Correction 1 supply voltage sensor erratic |
Occurrence frequency |
>= 16 |
[1/10 sec] |
absolute value of sensor value jump |
>= 4 |
[V/sec] |
30 [s] continuous |
| Power Factor Correction Gate driver voltage sensor Rail 2 |
Power Factor Correction 2 Gate driver voltage sensor short circuit to plus (SCB) |
voltage sensor value |
> 25.7 |
[V] |
ECU is active |
TRUE |
[-] |
1 [s] continuous |
2 DCY |
| Power Factor Correction 2 Gate driver voltage sensor short circuit to ground (SCG) |
voltage sensor value |
< 0.3 |
[V] |
ECU is active |
TRUE |
[-] |
1 [s] continuous |
| Power Factor Correction 2 Gate driver voltage sensor upper limit exceeded (ORH) |
voltage sensor value |
> 25.4 |
[V] |
ECU is active |
TRUE |
[-] |
1 [s] continuous |
| AND |
|
|
| voltage sensor value |
<= 25.7 |
[V] |
| Power Factor Correction 2 Gate driver voltage sensor lower limit exceeded (ORL) |
voltage sensor value |
< 6.3 |
[V] |
ECU is active |
TRUE |
[-] |
1 [s] continuous |
| AND |
|
|
| voltage sensor value |
>= 0.3 |
[V] |
| Power Factor Correction 2 Gate driver voltage sensor implausible value (RAT) |
Gate driver of respective power factor correction-digital signal processor Rail 2 |
off |
[-] |
ECU is active |
TRUE |
[-] |
1 [s] continuous |
| AND |
|
|
| voltage sensor value |
> 6 |
[V] |
| Power Factor Correction 2 Gate driver voltage sensor erratic |
Occurrence frequency |
>= 16 |
[1/10 sec] |
absolute value of sensor value jump |
>= 4 |
[V/sec] |
30 [s] continuous |
| Power Factor Correction supply voltage Rail 2 |
Power Factor Correction 2 supply voltage sensor short circuit to plus (SCB) |
voltage sensor value |
> 36.3 |
[V] |
ECU is active |
TRUE |
[-] |
1 [s] continuous |
2 DCY |
| Power Factor Correction 2 supply voltage sensor short circuit to ground (SCG) |
voltage sensor value |
< 0.4 |
[V] |
ECU is active |
TRUE |
[-] |
1 [s] continuous |
| Power Factor Correction 2 supply voltage sensor upper limit exceeded (ORH) |
voltage sensor value |
> 35.8 |
[V] |
ECU is active |
TRUE |
[-] |
1 [s] continuous |
| AND |
|
|
| voltage sensor value |
<= 36.3 |
[V] |
| Power Factor Correction 2 supply voltage sensor lower limit exceeded (ORL) |
voltage sensor value |
< 1.8 |
[V] |
ECU is active |
TRUE |
[-] |
1 [s] continuous |
| AND |
|
|
| voltage sensor value |
>= 0.4 |
[V] |
| Power Factor Correction 2 supply voltage sensor implausible value (RAT) |
Communication to power factor correction- digital signal processor |
on |
[-] |
ECU is active |
TRUE |
[-] |
1 [s] continuous |
| AND |
|
|
| voltage sensor value |
< 2 |
[V] |
| Power Factor Correction 2 supply voltage sensor erratic |
Occurrence frequency |
>= 16 |
[1/10 sec] |
absolute value of sensor value jump |
>= 4 |
[V/sec] |
30 [s] continuous |
| |
DC current |
> 0.5 |
[A] |
|
|
|
|
|
| DCDC short circuit |
Short circuit Rail 1 (DCDC) |
AND |
|
|
active charging process over Rail 1 |
yes |
[-] |
1 [s] continuous |
2 DCY |
| DC voltage |
< 7.5 |
[V] |
AND |
|
|
| AND |
|
|
for a time of |
>= 25 |
[ms] |
| Number of occurrences |
>=3 |
[-] |
|
|
|
| Short circuit Rail 2 (DCDC) |
DC current |
> 0.5 |
[A] |
|
|
|
1 [s] continuous |
| AND |
|
|
active charging process over Rail 2 |
yes |
[-] |
| DC voltage |
< 7.5 |
[V] |
AND |
|
|
| AND |
|
|
for a time of |
>= 25 |
[ms] |
| Number of occurrences |
>=3 |
[-] |
|
|
|
| HV-DC current sensor |
HV-DC current sensor Rail 1 upper limit exceeded (ORH) |
current sensor value |
> 52.4 |
[A] |
ECU is active |
TRUE |
[-] |
4 [s] continuous |
2 DCY |
| AND |
|
|
| current sensor value |
<= 56.4 |
[A] |
| HV-DC current sensor Rail 2 upper limit exceeded (ORH) |
current sensor value |
> 52.4 |
[A] |
ECU is active |
TRUE |
[-] |
4 [s] continuous |
| AND |
|
|
| current sensor value |
<= 56.4 |
[A] |
| HV-DC current sensor Rail 1 implausible value (RAT) |
absolute value of difference between actual DC output current and expected DC output current |
> 1 |
[A] |
active charging process over Rail 1 |
yes |
[-] |
1 [s] continuous |
| AND |
|
|
| voltage sensor value |
> 220 |
[V] |
| AND |
|
|
| DC output power |
>= 1200 |
[W] |
| HV-DC current sensor Rail 2 implausible value (RAT) |
absolute value of difference between actual DC output current and expected DC output current |
> 1 |
[A] |
active charging process over Rail 2 |
yes |
[-] |
1 [s] continuous |
| AND |
|
|
| voltage sensor value |
> 220 |
[V] |
| AND |
|
|
| DC output power |
>= 1200 |
[W] |
| HV-DC current sensor Rail 1 short circuit to ground (SCG) |
current sensor value |
< -8.7 |
[A] |
ECU is active |
TRUE |
[-] |
4 [s] continuous |
| HV-DC current sensor Rail 2 short circuit to ground (SCG) |
current sensor value |
< -8.7 |
[A] |
ECU is active |
TRUE |
[-] |
4 [s] continuous |
| HV-DC current sensor Rail 1 short circuit to battery (SCB) |
current sensor value |
> 56.4 |
[A] |
ECU is active |
TRUE |
[-] |
4 [s] continuous |
| HV-DC current sensor Rail 2 short circuit to battery (SCB) |
current sensor value |
> 56.4 |
[A] |
ECU is active |
TRUE |
[-] |
4 [s] continuous |
| HV-DC current sensor Rail 1 lower limit exceeded (ORL) |
current sensor value |
< -6.3 |
[A] |
ECU is active |
TRUE |
[-] |
4 [s] continuous |
| AND |
|
|
| current sensor value |
>= -8.7 |
[A] |
| HV-DC current sensor Rail 2 lower limit exceeded (ORL) |
current sensor value |
< -6.3 |
[A] |
ECU is active |
TRUE |
[-] |
4 [s] continuous |
| AND |
|
|
| current sensor value |
>= -8.7 |
[A] |
| HV-DC current sensor Rail 1 erratic |
Occurrence frequency |
>= 20 |
[1/10 sec] |
absolute value of sensor value jump |
>= 2 |
[A/sec] |
30 [s] continuous |
| AND |
|
|
| active charging process over Rail 1 |
yes |
[-] |
| AND |
|
|
| commanded current set point for a time of |
>= 10 |
[s] |
| HV-DC current sensor Rail 2 erratic |
Occurrence frequency |
>= 20 |
[1/10 sec] |
absolute value of sensor value jump |
>= 2 |
[A/sec] |
30 [s] continuous |
| AND |
|
|
| active charging process over Rail2 |
yes |
[-] |
| AND |
|
|
| commanded current set point for a time of |
>= 10 |
[s] |
| AC current sensor L 1 |
AC current sensor L 1 upper limit exceeded (ORH) |
current sensor value |
> 31.9 |
[A] |
ECU is active |
TRUE |
[-] |
4 [s] continuous |
2 DCY |
| AND |
|
|
| current sensor value |
<= 32.3 |
[A] |
| AC current sensor L 1 supply implausible value (RAT) |
current sensor value |
< 0.5 |
[A] |
car velocity |
> 3.7 |
[mph] |
4 [s] continuous |
| AC current sensor L 1 short circuit to ground (SCG) |
current sensor value |
< -2.8 |
[A] |
ECU is active |
|
[-] |
4 [s] continuous |
| AC current sensor L 1 short circuit to plus (SCB) |
current sensor value |
> 32.3 |
[A] |
ECU is active |
|
[-] |
4 [s] continuous |
| AC current sensor L 1 lower limit exceeded (ORL) |
current sensor value |
< -1.5 |
[A] |
ECU is active |
TRUE |
[-] |
4 [s] continuous |
| AND |
|
|
| current sensor value |
>= -2.8 |
[A] |
| AC current sensor L 1 erratic |
Occurrence frequency |
>= 20 |
[1/10 sec] |
absolute value of sensor value jump |
>= 2 |
[A/sec] |
30 [s] continuous |
| AND |
|
|
| active charging process over Rail 1 |
yes |
[-] |
| AND |
|
|
| commanded current set point for a time of |
>= 10 |
[s] |
| AC current sensor L 2 upper limit exceeded (ORH) |
current sensor value |
> 31.9 |
[A] |
ECU is active |
TRUE |
[-] |
4 [s] continuous |
|
| AND |
|
|
| current sensor value |
<= 32.3 |
[A] |
| AC current sensor L 2 supply implausible value (RAT) |
current sensor value |
< 0.5 |
[A] |
car velocity |
> 3.7 |
[mph] |
4 [s] continuous |
| AC current sensor L 2 short circuit to ground (SCG) |
current sensor value |
< -2.8 |
[A] |
ECU is active |
|
[-] |
4 [s] continuous |
| AC current sensor L 2 |
AC current sensor L 2 short circuit to plus (SCB) |
current sensor value |
> 32.3 |
[A] |
ECU is active |
|
[-] |
4 [s] continuous |
2 DCY |
| AC current sensor L 2 lower limit exceeded (ORL) |
current sensor value |
<-1.5 |
[A] |
ECU is active |
TRUE |
[-] |
4 [s] continuous |
| AND |
|
|
| current sensor value |
>= -2.8 |
[A] |
| AC current sensor L 2 erratic |
Occurrence frequency |
>= 20 |
[1/10sec] |
absolute value of sensor value jump |
>= 2 |
[A/sec] |
30 [s] continuous |
| AND |
|
|
| active charging process over Rail2 |
yes |
[-] |
| AND |
|
|
| commanded current set point for a time of |
>= 10 |
[s] |
| Power Factor Correction current sensor Rail 1 |
Power Factor Correction current sensor Rail 1 stage 1 short circuit to plus (SCB) |
current sensor value |
> 30.0 |
[A] |
ECU is active |
TRUE |
[-] |
1 [s] continuous |
2 DCY |
| Power Factor Correction current sensor Rail 1 stage 1 short circuit to ground (SCG) |
current sensor value |
< -2.9 |
[A] |
ECU is active |
TRUE |
[-] |
1 [s] continuous |
| Power Factor Correction current sensor Rail 1 stage 1 upper limit exceeded (ORH) |
current sensor value |
> 29.6 |
[A] |
ECU is active |
TRUE |
[-] |
1 [s] continuous |
| AND |
|
|
| current sensor value |
<= 30.0 |
[A] |
| Power Factor Correction current sensor Rail 1 stage 1 lower limit exceeded (ORL) |
current sensor value |
< -2.3 |
[A] |
ECU is active |
TRUE |
[-] |
1 [s] continuous |
| AND |
|
|
| current sensor value |
>= -2.9 |
[A] |
| Power Factor Correction current sensor Rail 1 implausible value (RAT) |
absolute value of difference between current Rail 1 stage 1 and current Rail 1 stage 2 |
> 5 |
[A] |
ECU is active |
TRUE |
[-] |
100 [s] continuous |
| Power Factor Correction current sensor Rail 1 stage 2 short circuit to plus (SCB) |
current sensor value |
> 30.0 |
[A] |
ECU is active |
TRUE |
[-] |
1 [s] continuous |
| Power Factor Correction current sensor Rail 1 stage 2 short circuit to ground (SCG) |
current sensor value |
< -2.9 |
[A] |
ECU is active |
TRUE |
[-] |
1 [s] continuous |
| Power Factor Correction current sensor Rail 1 stage 2 upper limit exceeded (ORH) |
current sensor value |
> 29.6 |
[A] |
ECU is active |
TRUE |
[-] |
1 [s] continuous |
| AND |
|
|
| current sensor value |
<= 30.0 |
[A] |
| Power Factor Correction current sensor Rail 1 stage 2 lower limit exceeded (ORL) |
current sensor value |
< -2.3 |
[A] |
ECU is active |
TRUE |
[-] |
1 [s] continuous |
| AND |
|
|
| current sensor value |
>= -2.9 |
[A] |
| Shutdown due to over current Power Factor Correction Rail 1 |
power factor correction-digital signal processor detected Rail1 AC-Over current (HW) - Stage 2 |
yes |
[-] |
ECU is active |
TRUE |
[-] |
1 [s] continuous |
| AND |
|
|
| Number of occurrences |
>=3 |
[-] |
| Power Factor Correction current sensor Rail 1 erratic |
Occurrence frequency |
>= 20 |
[1/10 sec] |
absolute value of sensor value jump |
>= 2 |
[A/sec] |
30 [s] continuous |
| AND |
|
|
| active charging process over Rail 1 |
yes |
[-] |
| AND |
|
|
| commanded current set point for a time of |
>= 10 |
[s] |
| Power Factor Correction current sensor Rail 2 |
Power Factor Correction current sensor Rail 2 stage 1 short circuit to plus (SCB) |
power factor correction current |
> 30.0 |
[A] |
ECU is active |
TRUE |
[-] |
1 [s] continuous |
2 DCY |
| Power Factor Correction current sensor Rail 2 stage 1 short circuit to ground (SCG) |
power factor correction current |
< -2.9 |
[A] |
ECU is active |
TRUE |
[-] |
1 [s] continuous |
| Power Factor Correction current sensor Rail 2 stage 1 upper limit exceeded (ORH) |
current sensor value |
> 29.6 |
[A] |
ECU is active |
TRUE |
[-] |
1 [s] continuous |
| AND |
|
|
| current sensor value |
<= 30.0 |
[A] |
| Power Factor Correction current sensor Rail 2 stage 1 lower limit exceeded (ORL) |
current sensor value |
< -2.3 |
[A] |
ECU is active |
TRUE |
[-] |
1 [s] continuous |
| AND |
|
|
| current sensor value |
>= -2.9 |
[A] |
| Power Factor Correction current sensor Rail 2 implausible value (RAT) |
absolute value of difference between current Rail 2 stage 1 and current Rail 2 stage 2 |
> 5 |
[A] |
ECU is active |
TRUE |
[-] |
100 [s] continuous |
| Power Factor Correction current sensor Rail 2 stage 2 short circuit to plus (SCB) |
power factor correction current |
> 30.0 |
[A] |
ECU is active |
TRUE |
[-] |
1 [s] continuous |
| Power Factor Correction current censor Rail 2 stage 2 short circuit to ground (SCG) |
power factor correction current |
< -2.9 |
[A] |
ECU is active |
TRUE |
[-] |
1 [s] continuous |
| Power Factor Correction current sensor Rail 2 stage 2 upper limit exceeded (ORH) |
current sensor value |
> 29.6 |
[A] |
ECU is active |
TRUE |
[-] |
1 [s] continuous |
| AND |
|
|
| current sensor value |
<= 30.0 |
[A] |
| Power Factor Correction current sensor Rail 2 stage 2 lower limit exceeded (ORL) |
current sensor value |
< -2.3 |
[A] |
ECU is active |
TRUE |
[-] |
1 [s] continuous |
| AND |
|
|
| current sensor value |
>= -2.9 |
[A] |
| Shutdown due to over current Power Factor Correction Rail 2 |
power factor correction-digital signal processor detected Rail 2 AC-Over current (HW) - Stage 2 |
yes |
[-] |
ECU is active |
TRUE |
[-] |
1 [s] continuous |
| AND |
|
|
| Number of occurrences |
>=3 |
[-] |
| Power Factor Correction current sensor Rail 2 erratic |
Occurrence frequency |
>= 20 |
[1/10 sec] |
absolute value of sensor value jump |
>= 2 |
[A/sec] |
30 [s] continuous |
| AND |
|
|
| active charging process over Rail 2 |
yes |
[-] |
| AND |
|
|
| |
|
|
|
commanded current set point for a time of |
>= 10 |
[s] |
|
|
| Relay error - and phase control |
Read back control Inrush-Relais Rail 1 short circuit to plus (SCB) |
sensor value |
> 25.7 |
[V] |
ECU is active |
TRUE |
[-] |
1 [s] continuous |
2 DCY |
| Read back control Inrush-Relais Rail 1 short circuit to ground (SCG) |
sensor value |
< 0.3 |
[V] |
ECU is active |
TRUE |
[-] |
1 [s] continuous |
| Read back control Inrush-Relais Rail 1 upper limit exceeded (ORH) |
voltage sensor value |
> 25.4 |
[V] |
ECU is active |
TRUE |
[-] |
1 [s] continuous |
| AND |
|
|
| voltage sensor value |
<= 25.7 |
[V] |
| Read back control Inrush-Relais Rail 1 lower limit exceeded (ORL) |
voltage sensor value |
< 1.3 |
[V] |
ECU is active |
TRUE |
[-] |
1 [s] continuous |
| AND |
|
|
| voltage sensor value |
>= 0.3 |
[V] |
| Read back control Inrush-Relais Rail 2 short circuit to plus (SCB) |
voltage sensor value |
> 25.7 |
[V] |
ECU is active |
TRUE |
[-] |
1 [s] continuous |
| Read back control Inrush-Relais Rail 2 short circuit to ground (SCG) |
voltage sensor value |
< 0.3 |
[V] |
ECU is active |
TRUE |
[-] |
1 [s] continuous |
| Read back control Inrush-Relais Rail 2 upper limit exceeded (ORH) |
voltage sensor value |
> 25.4 |
[V] |
ECU is active |
TRUE |
[-] |
1 [s] continuous |
| AND |
|
|
| voltage sensor value |
<= 25.7 |
[V] |
| Read back control Inrush-Relais Rail 2 lower limit exceeded (ORL) |
voltage sensor value |
< 1.3 |
[V] |
ECU is active |
TRUE |
[-] |
1 [s] continuous |
| AND |
|
|
| voltage sensor value |
>= 0.3 |
[V] |
| Digital Signal Processor State Machine |
Undefined state of State Machine Power Factor Correction 1 |
Undefined state of power factor correction- digital signal processor State-Machine detected |
yes |
[-] |
ECU is active |
TRUE |
[-] |
1 [s] continuous |
2 DCY |
| AND |
|
|
| Number of occurrences |
>=3 |
[-] |
| Undefined state of State Machine Power Factor Correction 2 |
Undefined state of power factor correction- digital signal processor State-Machine detected |
yes |
[-] |
ECU is active |
TRUE |
[-] |
1 [s] continuous |
| AND |
|
|
| Number of occurrences |
>=3 |
[-] |
| Time Out for charging of the Interlink-Capacitors Rail 1 (State Machine Power Factor Correction 1 - Time Out) |
Time Out detected |
yes |
[-] |
|
|
|
1 [s] continuous |
| absolute value of sensor value jump |
>= 2 |
[V/40ms] |
| AND |
|
|
| AND |
|
|
active charging process over Rail 1 |
yes |
[-] |
| Number of occurrences |
>=3 |
[-] |
|
|
|
| Time Out for charging of the Interlink-Capacitors Rail 2 (State Machine Power Factor Correction 2 - Time Out) |
Time Out detected |
yes |
[-] |
|
|
|
1 [s] continuous |
| absolute value of sensor value jump |
>= 2 |
[V/40ms] |
| AND |
|
|
| AND |
|
|
active charging process over Rail 2 |
yes |
[-] |
| Number of occurrences |
>=3 |
[-] |
|
|
|
| Rail 1 AC-voltage-operating-point not reached (State Machine Power Factor Correction 1 - Time Out) |
power factor correction-digital signal processor reported that Voltage Slope Rise Time Out occurred for Rail 1 |
yes |
[-] |
ECU is active |
TRUE |
[-] |
2 [s] continuous |
| AND |
|
|
| Number of occurrences |
>=3 |
[-] |
| Rail2 AC-voltage-operating-point not reached (State Machine Power Factor Correction2 - TimeOut) |
power factor correction-digital signal processor reported that Voltage Slope Rise Time Out occurred for Rail 2 |
yes |
[-] |
ECU is active |
TRUE |
[-] |
2 [s] continuous |
| AND |
|
|
| Number of occurrences |
>=3 |
[-] |
| Capacitor-interlink voltage Rail 1 too low (State Machine Power Factor Correction 1 - Time Out) |
power factor correction-digital signal processor reported that Interlink-Capacitors for Rail 1 has a voltage of |
< 380 |
[V] |
|
|
|
2 [s] continuous |
| active charging process over Rail 1 |
yes |
[-] |
| AND |
|
|
| AND |
|
|
for a time of |
>= 1 |
[s] |
| Number of occurrences |
>=3 |
[-] |
|
|
|
| Capacitor-interlink voltage Rail 2 too low (State Machine Power Factor Correction 2 - Time Out) |
power factor correction-digital signal processor reported that Interlink-Capacitors for Rail 2 has a voltage of |
< 380 |
[V] |
|
|
|
2 [s] continuous |
| active charging process over Rail 2 |
yes |
[-] |
| AND |
|
|
| AND |
|
|
for a time of |
>= 1 |
[s] |
| Number of occurrences |
>=3 |
[-] |
|
|
|
| RAM-Error Power Factor Correction 1 |
power factor correction-digital signal processor reports RAM-Error Rail 1 |
yes |
[-] |
ECU is active |
TRUE |
[-] |
1 [s] continuous |
|
| AND |
|
|
| Number of occurrences |
>=3 |
[-] |
| RAM-Error Power Factor Correction 2 |
power factor correction-digital signal processor reports RAM-Error Rail 2 |
yes |
[-] |
ECU is active |
TRUE |
[-] |
1 [s] continuous |
| AND |
|
|
| Number of occurrences |
>=3 |
[-] |
| ROM-Error Power Factor Correction 1 |
power factor correction-digital signal processor reports Flash-Error (ROM) Rail 1 |
yes |
[-] |
ECU is active |
TRUE |
[-] |
1 [s] continuous |
| AND |
|
|
| additional Digital Signal Processor Errors |
|
Number of occurrences |
>=3 |
[-] |
|
|
|
|
2 DCY |
| ROM-Error Power Factor Correction 2 |
power factor correction-digital signal processor reports Flash-Error (ROM) Rail 2 |
yes |
[-] |
ECU is active |
TRUE |
[-] |
1 [s] continuous |
| AND |
|
|
| Number of occurrences |
>=3 |
[-] |
| Message Time Out Power Factor Correction 1 |
power factor correction-digital signal processor reported Command-Time Out Rail 1 |
yes |
[-] |
Switched-Mode Power Supply |
ON |
[-] |
500 [ms] continuous |
| AND |
|
|
| Number of occurrences |
>=3 |
[-] |
| Message Time Out Power Factor Correction 2 |
power factor correction-digital signal processor reported Command-Time Out Rail 2 |
yes |
[-] |
Switched-Mode Power Supply |
ON |
[-] |
500 [ms] continuous |
| AND |
|
|
| Number of occurrences |
>=3 |
[-] |
| Set point-Error Power Factor Correction 1 |
power factor correction-digital signal processor reported Set point-Error for Rail 1 |
yes |
[-] |
ECU is active |
TRUE |
[-] |
500 [ms] continuous |
| AND |
|
|
| Number of occurrences |
>=3 |
[-] |
| Set point-Error Power Factor Correction 2 |
power factor correction-digital signal processor reported Set point-Error for Rail 2 |
yes |
[-] |
ECU is active |
TRUE |
[-] |
500 [ms] continuous |
| AND |
|
|
| Number of occurrences |
>=3 |
[-] |
| Set point-Error Rail 1 (DCDC) |
DCDC-digital signal processor reported Set point-Error for Rail 1 |
yes |
[-] |
ECU is active |
TRUE |
[-] |
500 [ms] continuous |
| AND |
|
|
| Number of occurrences |
>=3 |
[-] |
| Set point-Error Rail 2 (DCDC) |
DCDC-digital signal processor reported Set point-Error for Rail 2 |
yes |
[-] |
ECU is active |
TRUE |
[-] |
500 [ms] continuous |
| AND |
|
|
| Number of occurrences |
>=3 |
[-] |
| CAN communication |
U0028 - Vehicle Communication Bus A |
Hybrid CAN communication check - Bus off |
Bus Off Detection by Controller |
yes |
[-] |
ECU is active |
TRUE |
[-] |
500 [ms] continuous |
2 DCY |
| U0029 - Vehicle Communication Bus A Performance |
Hybrid CAN communication check - Global Time Out |
Global Time Out Detection |
yes |
[-] |
ECU is active |
TRUE |
[-] |
450 [ms] continuous |
2 DCY |
| HV-DC voltage sensor |
P0D20 - Battery Charger "A" Output Voltage Performance |
HV-DC output voltage too low |
voltage sensor value |
< 230 |
[V] |
charging current |
> 0 |
[A] |
1 [s] continuous |
2 DCY |
| HV-DC output voltage too high |
voltage sensor value |
> 450 |
[V] |
charging mode |
active |
[-] |
1 [s] continuous |
| HV-DC current sensor |
P0D22 - Battery Charger "A" Output Current Performance |
HV-DC output current Rail 1 too high |
current sensor value |
> 12, 5 |
[A] |
ECU is active |
TRUE |
[-] |
1 [s] |
2 DCY |
| HV-DC output current Rail 2 too high |
current sensor value |
> 12, 5 |
[A] |
ECU is active |
TRUE |
[-] |
1 [s] continuous |
| Safety line (local HV interlock) |
P0D15 - Battery Charging System "A" High Voltage Interlock Circuit/Open |
Safety line (local HV Interlock) open load |
LHVIL voltage |
> 0.77 |
[V] |
LHVIL coded |
yes |
[-] |
50 [ms] continuous |
2 DCY |
| AND |
|
|
| clamp 30 voltage |
>= 9 |
[V] |
| AND |
|
|
| AND |
|
|
clamp 30 voltage |
<= 16 |
[V] |
| LHVIL voltage |
< 3.77 |
[V] |
AND |
|
|
| System Board temperature |
>= -40 |
[°C] |
| AND |
|
|
| System Board temperature |
<= 130 |
[°C] |
| Safety line (local HV Interlock) short circuit to ground (SCG) |
LHVIL voltage |
< 0.77 |
[V] |
LHVIL coded |
yes |
[-] |
500 [ms] continuous |
| AND |
|
|
| clamp 30 voltage |
>= 9 |
[V] |
| AND |
|
|
| clamp 30 voltage |
<= 16 |
[V] |
| AND |
|
|
| System Board temperature |
>= -40 |
[°C] |
| AND |
|
|
| System Board temperature |
<= 130 |
[°C] |
| Safety line (local HV Interlock) short circuit to plus (SCB) |
LHVIL voltage |
> 7.73 |
[V] |
LHVIL coded |
yes |
[-] |
500 [ms] continuous |
| AND |
|
|
| clamp 30 voltage |
>= 9 |
[V] |
| AND |
|
|
| clamp 30 voltage |
<= 16 |
[V] |
| |
|
|
|
AND |
|
|
|
|
| System Board temperature |
>= -40 |
[°C] |
| AND |
|
|
| System Board temperature |
<= 130 |
[°C] |
| Proximity Socket Circuit |
P0D56 - Proximity Detection Circuit "A" |
Proximity detection open circuit (OC) |
PRX voltage |
> 4.778 |
[V] |
ECU is active |
TRUE |
[-] |
4000 [ms] continuous |
1DCY |
| AND |
|
|
| PRX voltage |
<= 5.409 |
[V] |
| OR |
| clamp 30 voltage |
< 8 |
[V] |
ECU is active |
TRUE |
[-] |
14000 [ms] |
| OR |
|
|
| clamp 30 voltage |
> 16 |
[V] |
| Proximity Socket Circuit Low |
P0D58 - Proximity Detection Circuit "A" Low |
Proximity detection short circuit to ground (SCG) |
PRX voltage |
< 0.53 |
[V] |
ECU is active |
TRUE |
[s] |
4000 [ms] continuous |
1DCY |
| Proximity Socket Circuit High |
P0D59 - Proximity Detection Circuit "A" High |
Proximity detection short circuit to plus (SCB) |
PRX voltage |
> 5.1 |
[V] |
ECU is active |
TRUE |
[s] |
4000 [ms] continuous |
1DCY |
| |
|
|
|
AND |
|
|
|
|
| AC plug |
LOCKED |
[-] |
| AND |
|
|
| for time |
>= 4 |
[s] |
| Control Pilot Circuit |
P0CF3 - Control Pilot Circuit /Open |
Control Pilot open circuit (OC) |
CP voltage |
< 500 |
[mV] |
AC plug |
NOT PLUGGED |
[-] |
3 [s] continuous |
2 DCY |
| Plug interlock |
P0D91 - Battery Charger Coupler Lock Control Circuit/Open |
Plug interlock disconnected |
Number of locking requests |
>= 3 |
[-] |
for time |
>= 400 |
ms |
1.2 [s] continuous |
2 DCY |
| AND |
|
|
| plug lock motor current |
==0 |
[A] |
| Temperature Sensor Socket AC |
P0D9B - Battery Charger Coupler Temperature Sensor "A" Circuit Low |
Charging socket temperature sensor 1 upper limit exceeded (ORH) |
temperature sensor voltage |
> 1288 |
[mV] |
AC plug |
PLUGGED |
[-] |
4 [s] continuous |
2 DCY |
| P0D9C - Battery Charger Coupler Temperature Sensor "A" Circuit High |
Charging socket temperature sensor 1 lower limit exceeded (ORL) |
temperature sensor voltage |
< 898 |
[mV] |
AC plug |
PLUGGED |
[-] |
4 [s] continuous |
2 DCY |
| Locking mechanism detection - Socket A (AC) |
P0DA0 - Battery Charger "A" Coupler Lock Position Sensor Circuit Low |
Locking mechanism charging socket A short circuit to ground (SCG) |
Coupler interlock voltage |
<= 0.3227 |
[V] |
ECU is active |
TRUE |
[-] |
5000 [ms] continuous |
2 DCY |
| Locking mechanism detection - Socket A (AC) |
P0DA1 - Battery Charger "A" Coupler Lock Position Sensor Circuit High |
Locking mechanism charging socket A short circuit to plus (SCB) |
Coupler interlock voltage |
> clamp 30 voltage * 0.951 |
[V] |
ECU is active |
TRUE |
[-] |
5000 [ms] continuous |
2 DCY |
| Locking mechanism detection - Socket A (AC) |
P0D9E - Battery Charger "A" Coupler Lock Position Sensor Circuit |
Locking mechanism charging socket A open circuit (OC) |
clamp 30 voltage |
> 16 |
[V] |
ECU is active |
TRUE |
[s] |
15000 [ms] continuous |
2 DCY |
| OR |
|
|
| clamp 30 voltage |
< 8 |
[V] |
| OR |
| Coupler interlock voltage |
=< clamp 30 voltage * 0.951 |
[V] |
ECU is active |
TRUE |
[-] |
5000 [ms] continuous |
| AND |
|
|
| Coupler interlock voltage |
>= clamp 30 voltage * 0.715 |
[V] |
| OR |
| Attempts of requests |
>= 3 |
[-] |
AC plug |
PLUGGED |
[-] |
10000 [ms] continuous |
| AND |
|
|
| plug locking request |
yes |
[-] |
| AND |
|
|
| Coupler interlock voltage |
< clamp 30 voltage * 0.512 |
[V] |
| OR |
|
|
| AC plug |
PLUGGED |
[-] |
| AND |
|
|
| plug locking request |
yes |
[-] |
| AND |
|
|
| Coupler interlock voltage |
> clamp 30 voltage * 0.714 |
[V] |
| OR |
|
|
| AC plug |
PLUGGED |
[-] |
| AND |
|
|
| plug unlocking request |
yes |
[-] |
| AND |
|
|
| Coupler interlock voltage |
< clamp 30 voltage * 0.512 |
[V] |
| OR |
|
|
| |
|
|
|
AC plug |
PLUGGED |
[-] |
|
|
| AND |
|
|
| plug unlocking request |
yes |
[-] |
| AND |
|
|
| Coupler interlock voltage |
> clamp 30 voltage * 0.714 |
[V] |
| P0D9F - Battery Charger "A" Coupler Lock Position Sensor Circuit Range/Performance |
Locking mechanism charging socket A implausible value (RAT) |
Coupler interlock voltage |
<0 |
[V] |
ECU is active |
TRUE |
[-] |
5000 [ms] continuous |
2 DCY |
| OR |
|
|
| Coupler interlock voltage |
>= clamp 30 voltage * 0.031 |
[V] |
| AND |
|
|
| Coupler interlock voltage |
<= clamp 30 voltage * 0.127 |
[V] |
| OR |
|
|
| Coupler interlock voltage |
>= clamp 30 voltage * 0.21 |
[V] |
| AND |
|
|
| Coupler interlock voltage |
<= clamp 30 voltage * 0.512 |
[V] |
| OR |
|
|
| Coupler interlock voltage |
>= clamp 30 voltage * 0.714 |
[V] |
| AND |
|
|
| Coupler interlock voltage |
<= clamp 30 voltage * 0.715 |
[V] |
| CAN Time Out |
U0111 - Lost Communication With Battery Energy Control Module "A" |
Lost communication with BECM control module |
CAN Message Time Out |
DETECTED |
[-] |
ECU is active |
TRUE |
[-] |
5 [s] continuous |
2 DCY |
| U0122 - Lost Communication With Vehicle Dynamics Control Module |
Lost communication with BSCM control module |
CAN Message Time Out |
DETECTED |
[-] |
Clamp 15 |
on |
[-] |
2 [s] continuous |
2 DCY |
| CAN Value Error |
BSCM communication value error |
invalid message content |
DETECTED |
[-] |
Clamp 15 |
on |
[-] |
2 [s] continuous |
2 DCY |
| CAN Time Out |
U0100 - Lost Communication With ECM/PCM "A" |
Lost communication with ECM control module |
CAN Message Time Out |
DETECTED |
[-] |
ECU is active |
TRUE |
[-] |
5 [s] continuous |
2 DCY |
| CAN Value Error |
U0412 - Invalid Data Received From Battery Energy Control Module "A" |
BECM communication value error |
invalid message content |
DETECTED |
[-] |
ECU is active |
TRUE |
[-] |
5 [s] continuous |
2 DCY |
| AC infrastructure |
P0D67 - Battery Charger Control Module "A" Performance |
Over current L1 |
Number of occurrences |
> 5 |
[-] |
Charging mode |
active |
[-] |
1 [s] continuous |
2 DCY |
| AND |
|
|
| AC current sensor value |
> max. AC current +1.6 |
[A] |
| Temperature sensor Power Factor Correction 1 |
Temperature sensor Power Factor Correction 1 upper limit exceeded ( |
Temperature |
> 130 |
[°C] |
ECU is active |
TRUE |
[-] |
1 [s] continuous |
2 DCY |
| Temperature sensor Power Factor Correction 1 lower limit exceeded (ORL) |
Temperature |
< -50 |
[°C] |
ECU is active |
TRUE |
[-] |
1 [s] continuous |
| Temperature sensor Power Factor Correction 2 |
Temperature sensor Power Factor Correction 2 upper limit exceeded ( |
Temperature |
> 130 |
[°C] |
ECU is active |
TRUE |
[-] |
1 [s] continuous |
2 DCY |
| Temperature sensor Power Factor Correction 2 lower limit exceeded (ORL) |
Temperature |
< -50 |
[°C] |
ECU is active |
TRUE |
[-] |
1 [s] continuous |
| FuSi error |
Intervention by LMSF |
Functional safety error |
DETECTED |
[-] |
ECU is active |
TRUE |
[-] |
500 [ms] continuous |
2 DCY |