Bench Testing: Rotor
- Place ohmmeter on lowest scale. Connect ohmmeter across slip rings. Ensure resistance is within specification. See ROTOR RESISTANCE table.
- If resistance is too low, rotor has short circuit and must be replaced. If resistance is infinite (no continuity), rotor has open circuit and must be replaced.
- Place ohmmeter on X1000 scale. Connect ohmmeter between rotor core and either slip ring. Continuity should not exist. If continuity exists, rotor is grounded and must be replaced.
ROTOR RESISTANCE
| Application | Ohms |
|---|---|
| 80-Amp Generator | 2.6-3.2 |
| 140-Amp Generator | 2.4-2.8 |