66 54 005 Removing And Installing/Replacing Control Unit For Night Vision System
IMPORTANT:
Read and comply with notes on PROTECTION AGAINST ELECTROSTATIC DAMAGE (ESD PROTECTION)
Necessary preliminary tasks:
- Disconnect battery negative lead
- Remove TRIM FOR INSTRUMENT PANEL ON RIGHT
Disconnect plug connection (1).
Press tab (2) to side and remove control unit (3) from module carrier.
Replacement:
Carry out PROGRAMMING/CODING .
NOTE:
New component contains a CD with deblocking code.
CD is requested during coding/programming by the SSS.